Peripheral Catheter Insertion KitRecalls & reported problems across all models
Bard Access Systems, Inc. · 54 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 895
- Deaths reported
- 0
- Injuries reported
- 229
- Recalls
- 1
We found 54 models of Peripheral Catheter Insertion Kit by Bard Access Systems, Inc. in the FDA's device registry (GUDID). Together they are named in 895 adverse event reports in the FDA's MAUDE database, received between Jul 1, 2016 and Sep 23, 2026 — classified as 229 injuries, 666 malfunctions.
The most frequently reported specific device problem is “Break” (210 reports).
1 FDA recall record name at least one of these models by its device identifier.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Peripheral Catheter Insertion Kit recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Mar 17, 2020Terminated
Iincorrectly packaged without the required lidocaine as labeled
Z-1946-2020 · Root cause: Packaging change control · Recall details · FDA record ↗
Most reported Peripheral Catheter Insertion Kit problems
Device problems
- Break210
- Defective Component97
- Activation Problem95
- Fluid/Blood Leak85
- Improper or Incorrect Procedure or Method69
- Material Frayed61
- Material Deformation59
- Retraction Problem44
Patient problems
- No Clinical Signs, Symptoms or Conditions280
- No Known Impact Or Consequence To Patient191
- Foreign Body In Patient172
- No Consequences Or Impact To Patient122
- Pain28
- Device Embedded In Tissue or Plaque21
- No Patient Involvement17
- Insufficient Information15
Peripheral Catheter Insertion Kit models
54 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Peripheral Catheter Insertion Kit AC0202250Catheter,intravascular,therapeutic,short-term less than 30 days172 reports
- Peripheral Catheter Insertion Kit F118100Catheter,intravascular,therapeutic,short-term less than 30 days67 reports
- Peripheral Catheter Insertion Kit F318108PTCatheter,intravascular,therapeutic,short-term less than 30 days60 reports
- Peripheral Catheter Insertion Kit ST018101DMidline catheter1 recall8 reports
- Peripheral Catheter Insertion Kit AC0182250Catheter,intravascular,therapeutic,short-term less than 30 days50 reports
- Peripheral Catheter Insertion Kit F118108PTCatheter,intravascular,therapeutic,short-term less than 30 days50 reports
- Peripheral Catheter Insertion Kit F220108PTCatheter,intravascular,therapeutic,short-term less than 30 days50 reports
- Peripheral Catheter Insertion Kit F320108PTCatheter,intravascular,therapeutic,short-term less than 30 days42 reports
- Peripheral Catheter Insertion Kit F120108PTCatheter,intravascular,therapeutic,short-term less than 30 days33 reports
- Peripheral Catheter Insertion Kit F118101Catheter,intravascular,therapeutic,short-term less than 30 days27 reports
- Peripheral Catheter Insertion Kit F320088PTCatheter,intravascular,therapeutic,short-term less than 30 days21 reports
- Peripheral Catheter Insertion Kit AC0201250Catheter,intravascular,therapeutic,short-term less than 30 days19 reports
- Peripheral Catheter Insertion Kit F218108PTCatheter,intravascular,therapeutic,short-term less than 30 days18 reports
- Peripheral Catheter Insertion Kit F120080Catheter,intravascular,therapeutic,short-term less than 30 days17 reports
- Peripheral Catheter Insertion Kit F120100Catheter,intravascular,therapeutic,short-term less than 30 days16 reports
- Peripheral Catheter Insertion Kit F318107TCatheter,intravascular,therapeutic,short-term less than 30 days16 reports
- Peripheral Catheter Insertion Kit F322088PTCatheter,intravascular,therapeutic,short-term less than 30 days16 reports
- Peripheral Catheter Insertion Kit F320107TCatheter,intravascular,therapeutic,short-term less than 30 days14 reports
- Peripheral Catheter Insertion Kit F118080Catheter,intravascular,therapeutic,short-term less than 30 days13 reports
- Peripheral Catheter Insertion Kit F120101Catheter,intravascular,therapeutic,short-term less than 30 days13 reports
- Peripheral Catheter Insertion Kit F120107TCatheter,intravascular,therapeutic,short-term less than 30 days13 reports
- Peripheral Catheter Insertion Kit F220088PTCatheter,intravascular,therapeutic,short-term less than 30 days11 reports
- Peripheral Catheter Insertion Kit F222088PTCatheter,intravascular,therapeutic,short-term less than 30 days11 reports
- Peripheral Catheter Insertion Kit F118107TCatheter,intravascular,therapeutic,short-term less than 30 days10 reports
- Peripheral Catheter Insertion Kit F120081Catheter,intravascular,therapeutic,short-term less than 30 days9 reports
- Peripheral Catheter Insertion Kit F318088PTCatheter,intravascular,therapeutic,short-term less than 30 days9 reports
- Peripheral Catheter Insertion Kit F220101Catheter,intravascular,therapeutic,short-term less than 30 days8 reports
- Peripheral Catheter Insertion Kit AC0181250Catheter,intravascular,therapeutic,short-term less than 30 days6 reports
- Peripheral Catheter Insertion Kit AC0182252Catheter,intravascular,therapeutic,short-term less than 30 days6 reports
- Peripheral Catheter Insertion Kit F320087TCatheter,intravascular,therapeutic,short-term less than 30 days6 reports
- Peripheral Catheter Insertion Kit F118088PTCatheter,intravascular,therapeutic,short-term less than 30 days6 reports
- Peripheral Catheter Insertion Kit F120088PTCatheter,intravascular,therapeutic,short-term less than 30 days6 reports
- Peripheral Catheter Insertion Kit F218088PTCatheter,intravascular,therapeutic,short-term less than 30 days6 reports
- Peripheral Catheter Insertion Kit F122080Catheter,intravascular,therapeutic,short-term less than 30 days5 reports
- Peripheral Catheter Insertion Kit F218101Catheter,intravascular,therapeutic,short-term less than 30 days5 reports
- Peripheral Catheter Insertion Kit AC0202252Catheter,intravascular,therapeutic,short-term less than 30 days5 reports
- Peripheral Catheter Insertion Kit F122088PTCatheter,intravascular,therapeutic,short-term less than 30 days5 reports
- Peripheral Catheter Insertion Kit F320088TCatheter,intravascular,therapeutic,short-term less than 30 days5 reports
- Peripheral Catheter Insertion Kit F120087TCatheter,intravascular,therapeutic,short-term less than 30 days4 reports
- Peripheral Catheter Insertion Kit F318087TCatheter,intravascular,therapeutic,short-term less than 30 days4 reports
- Peripheral Catheter Insertion Kit F322087TCatheter,intravascular,therapeutic,short-term less than 30 days4 reports
- Peripheral Catheter Insertion Kit F218081Catheter,intravascular,therapeutic,short-term less than 30 days3 reports
- Peripheral Catheter Insertion Kit AC0221250Catheter,intravascular,therapeutic,short-term less than 30 days3 reports
- Peripheral Catheter Insertion Kit ST120101Midline catheter3 reports
- Peripheral Catheter Insertion Kit ST020101DMidline catheter3 reports
- Peripheral Catheter Insertion Kit F320108TCatheter,intravascular,therapeutic,short-term less than 30 days3 reports
- Peripheral Catheter Insertion Kit F118081Catheter,intravascular,therapeutic,short-term less than 30 days2 reports
- Peripheral Catheter Insertion Kit F220081Catheter,intravascular,therapeutic,short-term less than 30 days2 reports
- Peripheral Catheter Insertion Kit ST118101Midline catheter2 reports
- Peripheral Catheter Insertion Kit ST220081Midline catheter2 reports
- Peripheral Catheter Insertion Kit F118087TCatheter,intravascular,therapeutic,short-term less than 30 days2 reports
- Peripheral Catheter Insertion Kit F122087TCatheter,intravascular,therapeutic,short-term less than 30 days2 reports
- Peripheral Catheter Insertion Kit ST020100Midline catheter1 report
- Peripheral Catheter Insertion Kit F318088TCatheter,intravascular,therapeutic,short-term less than 30 days1 report
Recent Peripheral Catheter Insertion Kit adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
InjurySep 23, 2026Break
It was reported that the tip of PowerGlide broke off in the patient -1.15cm. No adverse event or serious injury reported. The retained catheter tip was in the tissue. The tip was not removed from patient. No complications or additional intervention needed.
Patient problems: Foreign Body In Patient
MAUDE report 50873057 ↗MalfunctionJun 30, 2026Activation Problem
IT WAS REPORTED THAT POWERGLIDE PRO DOES NOT SAFETY UPON PROCEDURE COMPLETION/NEEDLE RETRACTION. NO OTHER ISSUES WITH PROCEDURE, SAFETY BARREL/CAP PIECE JUST DOES NOT DEPLOY. A SPECIFIC NUMBER OF AFFECTED DEVICES OR PATIENTS WAS NOT PROVIDED BY THE COMPLAINANT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25673051 ↗MalfunctionJun 3, 2026
IN THE PROCESS OF PLACING A BARD POWERGLIDE MIDLINE, A MALFUNCTION OCCURED. THE CATHETER IS DESIGNED TO BE INSERTED OVER A WIRE. SEVERAL ATTEMPTS TO THREAD THE CATHETER OVER THE WIRE WERE UNSUCCESSFUL. A SECOND FULL STERILE KIT NEEDED TO BE OPENED AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25373795 ↗MalfunctionMay 13, 2026Misassembled; Activation Problem
IT WAS REPORTED THAT NO SAFETY. NO FURTHER DETAILS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25162909 ↗MalfunctionMay 12, 2026Material Deformation
IT WAS REPORTED A DEFECTIVE POWERGLIDE CATHETER WITH ODD CRIMPS/KINKS IN IT, FOUND ON INSERTION. THERE WAS NO HARM TO THE PATIENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25155994 ↗MalfunctionMay 5, 2026Activation Problem
IT WAS REPORTED THE NEEDLE TIP SAFETY MECHANISM DID NOT DEPLOY. NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25086825 ↗MalfunctionMay 5, 2026Fluid/Blood Leak
IT WAS REPORTED THERE IS A DEFECT IN THE CATHETER ITSELF AT THE HUB-CATHETER CONNECTION. IT IS A VERY SLIGHT HOLD, AND IT LEAKS. LINE LEAKAGE WAS DISCOVERED ON 04/18/26, LINE WAS PLACED ON (B)(6) 2026 (20/10 PG) TO RT BASILIC VEIN. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25086823 ↗MalfunctionMay 5, 2026Fluid/Blood Leak
IT WAS REPORTED A DEFECT IN THE CATHETER ITSELF AT THE HUB-CATHETER CONNECTION. IT IS A VERY SLIGHT HOLD AND IT LEAKS, IT WAS NOT NOTICED UNTIL IT WAS A BLOODY MESS. THERE WAS BLOOD COMING OUT OF THE CONNECTION POINT. THE LINE WAS REPLACED. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 25086649 ↗InjuryApr 27, 2026Difficult to Remove
IT WAS REPORTED VIA MEDWATCH THAT WHILE I WAS PLACING A POWER GLIDE FOR PATIENT IN R [RIGHT] BASILIC. I LOCATED VESSEL AND WAS ABLE TO GET BLOOD RETURN. I ADVANCED WIRE WITHOUT ANY ISSUES OR RESISTANCE. I THEN WENT TO ADVANCE CATHETER. THE DEVICE SPLIT APART AT THE TIP AND THE CATHETER WOULD NOT ADVANCE. THE PATIENT COMPLAINED OF PAIN. I ATTEMPTED TO PULL DEVICE BACK AND AT THE INSERTION SITE, THE DEVICE WAS NOT COMPLETELY COMING OUT. THE SKIN WAS BEING PULLED/TUGGED LIKE THE OBJECT WAS LARGER THAN THE INSERTION SITE. NO MAJOR HARM TO THE PATIENT. IR ASSISTED IN REMOVAL OF DEVICE FROM PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25000928 ↗MalfunctionApr 24, 2026Activation Problem
IT WAS REPORTED THAT ON FRIDAY, MARCH 27, WE ENCOUNTERED AN ISSUE WITH THE POWERGLIDE PRO CATHETER. UPON WITHDRAWAL OF THE NEEDLE/GUIDEWIRE FROM THE PATIENT, THE NEEDLE TIP SAFETY MECHANISM DID NOT DEPLOY. USUALLY, THERE IS A LOCKING CHAMBER THAT DEPLOYS TO COVER THE NEEDLE TIP. NO PATIENT HARM OCCURRED IN THIS CASE. HOWEVER, THIS LED TO AN EXPOSED NEEDLE TIP WHEN SEPARATING THE NEEDLE FROM THE IV CATHETER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24981899 ↗MalfunctionApr 23, 2026Fluid/Blood Leak
IT WAS REPORTED BY CUSTOMER THAT REPORTS LEAKING AT THE CATHETER HUB. NO HARM REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24965761 ↗MalfunctionApr 14, 2026Activation Problem
IT WAS REPORTED THAT A NURSE WENT TO SAFETY A POWERGLIDE AND THE SAFETY CLIP PORTION REMAINED IN THE SEPTUM, CAUSING THE NEEDLE TO COME OUT WITHOUT ANY SAFETY. NO EFFECT ON PLACEMENT OR CLINICIAN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24877036 ↗InjuryApr 14, 2026Break
IT WAS REPORTED THAT THE POWERGLIDE CATHETER SHEARED AND DISLODGED INTO PATIENT DURING INSERTION. PATIENT NEEDED TO HAVE IT SURGICALLY REMOVED.
Patient problems: Foreign Body In Patient
MAUDE report 24872528 ↗MalfunctionApr 9, 2026
I WAS PLACING A POWER GLIDE FOR PATIENT IN R [RIGHT] BASILIC. I LOCATED VESSEL AND WAS ABLE TO GET BLOOD RETURN. I ADVANCED WIRE WITHOUT ANY ISSUES OR RESISTANCE. I THEN WENT TO ADVANCE CATHETER. THE DEVICE SPLIT APART AT THE TIP AND THE CATHETER WOULD NOT ADVANCE. THE PATIENT COMPLAINED OF PAIN. I ATTEMPTED TO PULL DEVICE BACK AND AT THE INSERTION SITE, THE DEVICE WAS NOT COMPLETELY COMING OUT. THE SKIN WAS BEING PULLED/TUGGED LIKE THE OBJECT WAS LARGER THAN THE INSERTION SITE.
Patient problems: Pain
MAUDE report 24829900 ↗MalfunctionApr 6, 2026Activation Problem
IT WAS REPORTED THAT THE CLEAR PIECE THAT COVERS THE NEEDLE FOR SAFETY CAME OFF. NO OTHER INFORMATION WAS PROVIDED. ADDITIONAL INFORMATION: NO NEEDLESTICK INJURY OCCURRED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24795147 ↗
Other Bard Access Systems, Inc. products
- Port Access Needle122 models · 3,744 reports · 3 recalls
- Groshong NXT ClearVue Catheter8 models · 3,266 reports
- PowerPort ClearVUE27 models · 1,993 reports · 15 recalls
- Site~Rite 8 Ultrasound System11 models · 1,965 reports
- PowerPort M.R.I., ChronoFlex22 models · 1,642 reports · 1 recall
- PowerPICC Provena116 models · 1,337 reports · 2 recalls
- PowerPort M.R.I., Groshong10 models · 1,285 reports
- Navarre15 models · 1,228 reports
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page