PowerPICC SOLO CK000637Recalls & reported problems
Bard Access Systems, Inc. · Catheter Placement Kit · Class 2 · Implant
All models of PowerPICC SOLO (78)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00801741128233), received between Sep 18, 2017 and May 17, 2018 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Crack” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Crack2
- Leak/Splash2
- Split1
Patient problems
- No Known Impact Or Consequence To Patient3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 17, 2018Crack; Leak/Splash
IT WAS REPORTED THAT THE PICC NURSE PLACED THE PICC AROUND MIDNIGHT AND FLUSHED THE LINE. ON THE MORNING OF (B)(6) 2018 THE PICC NURSE WENT TO FLUSH THE LINE AFTER INFUSION AND THE PICC LEAKED AT THE HUB. THE FACILITY STATED THAT THE "HUB IS ACTUALLY BROKEN/CRACKED." THE PICC LINE WAS REMOVED AND ANOTHER WAS PLACED. NO PATIENT INJURY REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7522272 ↗MalfunctionFeb 7, 2018Crack; Leak/Splash
THE FACILITY REPORTED TO THE SALES REP THAT DURING PRIMING THE PICC WITH SALINE PRIOR TO PLACEMENT, VASCULAR ACCESS NURSE NOTICED SALINE APPEARED TO EXIT THE CATHETER FROM A SITE OTHER THAN THE CATHETER TIP. IT WAS STATED THE NURSE DISCONNECTED SYRINGE AND RECONNECTED TO ASSURE ALL CONNECTIONS WERE CORRECT AND NOTICED A VERTICAL CRACK IN THE CATHETER HUB. ON ATTEMPT TO SHOW STAFF WHERE CATHETER WAS CRACKED IT WAS REPORTED THAT THE CATHETER HUB SPLIT AT THE COLORED BIFURCATION. ANOTHER KIT WAS USED TO COMPLETE THE PROCEDURE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7250186 ↗MalfunctionSep 18, 2017Split
PER MEDWATCH REPORT, THE FACILITY REPORTED: "PATIENT PREPPED AND DRAPED PER PROCEDURE PROTOCOL. RIGHT BRACHIAL VEIN ACCESSED WITH 21G NEEDLE REMOVED OVER WIRE. 5FR MICRO-INTRODUCER ADVANCED OVER 0.018 GUIDEWIRE. GUIDEWIRE REMOVED FROM MICRO-INTRODUCER AND MICRO-INTRODUCER DILATOR CAPPED OFF WITH DEAD END CAP. PICC PREPPED FOR INSERTION. DILATOR REMOVED FROM BREAKAWAY SHEATH. PICC INSERTED WITHOUT ISSUE. PICC TIP PLACEMENT VERIFIED WITH SHERLOCK AND 3CG. UPON TRYING TO REMOVE THE BREAKAWAY SHEATH ONE OF THE RED FINGER PIECES THAT NORMALLY IS USED TO SPLIT THE SHEATH AND PULL IT OUT BROKE AWAY FROM THE SHEATH. SHEATH PORTION REMAINED INTACT AND WAS REMOVED OVER THE EXTERNAL PORTION OF THE PICC LINE THEN SPLIT AND REMOVED AWAY FROM THE LINE WITH THE REMAINING RED FINGER PIECE. BREAKAWAY SHEATH VISUALLY INSPECTED NO PIECES MISSING. PICC LINE SECURED AND DRESSED PER POLICY. PCXR OBTAINED THAT INCLUDED THE RIGHT ARM. PICC LINE APPEARS TO BE IN GOOD POSITION AND NOTHING ELSE NOTED ON X-RAY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6872100 ↗
Other Catheter,intravascular,therapeutic,long-term greater than 30 days devices
- Groshong NXT ClearVue Catheter 7617405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,708 reports
- Groshong NXT ClearVue Catheter 7655405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,536 reports
- PowerPICC Catheter 3174118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall402 reports
- L-Cath™ S/L PICC S/L 26GA (1.9F) x 30cmArgon Medical Devices, Inc. · Catheter,Intravascular,Therapeutic,Long-Term Greater Than 30 Days2 recalls245 reports
- PowerPICC SOLO2 Catheter 1194108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 recalls216 reports
- Broviac 0600520Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall265 reports
- Groshong® Catheter 7717405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days279 reports
- PowerPICC® Catheters 1174108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall222 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page