Peripheral Catheter Insertion Kit F118088PTRecalls & reported problems

Bard Access Systems, Inc. · PowerGlide 18Ga, 8cm · Class 2

All models of Peripheral Catheter Insertion Kit (54)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00801741140556), received between Mar 29, 2019 and Mar 20, 2025 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Activation Problem1
  • Contamination /Decontamination Problem1
  • Malposition of Device1
  • Material Discolored1
  • Material Frayed1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Known Impact Or Consequence To Patient2
  • Foreign Body In Patient1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 20, 2025Material Frayed; Material Frayed

    IT WAS REPORTED WHILE TRYING TO INSERT A 18G 10CM MIDLINE INTO THE PATIENT, THE GUIDEWIRE BECAME STUCK. UPON REMOVING THE NEEDLE/GUIDEWIRE THE GUIDE WIRE RIPPED AND PULLED HALF MOSTLY OUT. UPON REMOVING THE CATHETER, THE REST OF THE GUIDEWIRE APPEARED AT THE END OF THE CATHETER TIP WITH BENDS/COILS. PATIENT HAD TO BE STUCK AGAIN. NO HARM TO PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21651970 ↗
  • MalfunctionAug 23, 2024Material Discolored; Contamination /Decontamination Problem; Material Discolored; Contamination /Decontamination Problem

    IT WAS REPORTED BY CUSTOMER THAT UNKNOWN YELLOW SUBSTANCE ON THE PACKAGE. NO OTHER INFORMATION PROVIDED, AT THIS TIME.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20052165 ↗
  • InjurySep 29, 2022Break; Break

    IT WAS REPORTED BY THE CUSTOMER THAT THE "PATIENT HAD POWERGLIDE INSERTED IN THE BRACHIAL VEIN FOR ALMOST A MONTH. CONTACT WAS ALERTED THAT THE CATHETER HAS COMPLETELY FRACTURED AT THE DISTAL END OF THE CATHETER. NURSE REMOVED CATHETER HUB BUT VASCULAR DECIDED TO LEAVE THE CATHETER IN PLACE AND MONITOR IT FROM OUTPATIENT AND ONLY REMOVE IF NECESSARY. THEY HAD NOT BEEN USING THE CATHETER FOR A FEW WEEKS AND THE PATIENT IS ACTIVE IN A WHEELCHAIR."

    Patient problems: Foreign Body In Patient

    MAUDE report 15506796 ↗
  • MalfunctionNov 6, 2019Activation Problem; Activation Problem

    IT WAS REPORTED THAT IT WAS A REGULAR INSERTION AND UPON PULLING OUT THE SAFETY CAP CAME OFF INSTEAD OF REMAINING OVER THE NEEDLE. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9285378 ↗
  • MalfunctionMay 16, 2019Malposition of Device

    IT WAS REPORTED THAT POWERGLIDE WAS INSERTED BY WRITER INTO PATIENT'S LEFT BASILIC VEIN WITH ULTRASOUND. AFTER CATHETER WAS DEPLOYED AND NEEDLE REMOVED THE GUIDEWIRE "UNRAVELED" AND THE TIP BECAME LODGED IN THE MID SECTION OF THE CATHETER THUS PULLING THE WHOLE CATHETER BACK OUT OF THE VEIN. PRESSURE WAS HELD AND HOMEOSTASIS TO THE VEIN WAS ACHIEVED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8617233 ↗
  • MalfunctionMar 29, 2019Break

    IT WAS REPORTED THAT THE POWERGLIDE CATHETERS SHEARED ON THE NEEDLE DURING INSERTION. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8465275 ↗

Other Catheter,intravascular,therapeutic,short-term less than 30 days devices

All Catheter,intravascular,therapeutic,short-term less than 30 days devices →