The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00801741140730), received between Oct 1, 2021 and Nov 13, 2023 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak3
  • Improper or Incorrect Procedure or Method1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 13, 2023Fluid/Blood Leak; Material Deformation; Fluid/Blood Leak; Material Deformation

    IT WAS REPORTED BY CUSTOMER THAT MIDLINE CATHETER LEAKING AT HUB OF CATHETER. PICC NURSE NOTED THAT WHEN LINE FLUSHED WITH NORMAL SALINE, IT LEAKED BACK OUT FROM THE HUB. NURSES HAVE NOTICED THAT IN GENERAL THIS PRODUCT HAS ISSUES WITH KINKING AND/OR TWISTED AT THE HUB OF THE CATHETER WITH SEVERAL PATIENTS. A SPECIFIC NUMBER OF AFFECTED DEVICES OR PATIENTS WAS NOT PROVIDED BY THE COMPLAINANT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18124656 ↗
  • MalfunctionMar 25, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED "MIDLINE CATHETER LEAKING AT HUB OF CATHETER. PICC NURSE NOTED THAT WHEN LINE FLUSHED WITH NORMAL SALINE, IT LEAKED BACK OUT FROM THE HUB." PLACEMENT DATE:(B)(6) 2022. EXPLANT DATE: N/A WAS THERE ANY PATIENT HARM REPORTED? NO IF YES, PLEASE DESCRIBE THE HARM, HOW IT WAS TREATED AND THE OUTCOME. AT WHAT POINT DURING DEVICE USE WAS THE LEAK DISCOVERED (I.E. INSERTION, INFUSION, REMOVAL) PICC NURSE NOTED THAT WHEN LINE FLUSHED WITH NORMAL SALINE, IT LEAKED BACK OUT FROM THE HUB. WAS THE CATHETER FRACTURE INTERNAL TO THE PATIENT OR EXTERNAL? UNKNOWN WHAT WAS INFUSION WHEN THE LEAK WAS DISCOVERED? SALINE ANY PATIENT SYMPTOMS RELATED TO FLUID LEAK? UNKNOWN WAS THE CATHETER REMOVED? YES WAS A NEW CATHETER PLACED? YES WHAT TYPE OF CATHETER SECUREMENT WAS UTILIZED? UNKNOWN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13905265 ↗
  • MalfunctionOct 1, 2021Fluid/Blood Leak; Improper or Incorrect Procedure or Method; Fluid/Blood Leak; Improper or Incorrect Procedure or Method

    IT WAS REPORTED "WHEN DOING POWERGLIDE TRAINING, DURING A BEDSIDE INSERTION, CATHETER WAS PLACED WITHOUT DIFFICULTLY (NO RESHEATHING OF CATHETER OR STRESS TO DEVICE NOTED). AFTER CATHETER WAS ADVANCED ATTEMPTED TO ASPIRATE BLOOD RETURN AND AIR WAS NOTED ENTERING THE SYRINGE. INSURED THAT EXTENSION SET WAS SECURE AND PROPERLY ATTACHED. AGAIN ATTEMPTED TO ASPIRATE FOR BLOOD RETURN AND AIR AGAIN NOTED ENTERING THE SYRINGE, WHEN FLUSHING CATHETER WAS NOTED TO BE LEAKING WHERE THE CATHETER JOINS THE HUB. CATHETER DC'ED INTACT WITH NO INJURY TO PATIENT." ADD INFO RCVD 09/17/2021: WHAT THEY¿RE BEING TREATED FOR: RHABDOMYOLYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12565291 ↗

Other Catheter,intravascular,therapeutic,short-term less than 30 days devices

All Catheter,intravascular,therapeutic,short-term less than 30 days devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page