PowerPICC Provena SOLO CK000931ARecalls & reported problems

Bard Access Systems, Inc. · Catheter Placement Kit · Class 2 · Implant

All models of PowerPICC Provena SOLO (19)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00801741220043), received between Jan 3, 2025 and Apr 6, 2026 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak3
  • Defective Component2
  • Crack1
  • Difficult to Insert1
  • Patient-Device Incompatibility1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Thrombosis/Thrombus1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 6, 2026Crack

    IT WAS REPORTED, PLACED A PICC SUCCESSFULLY THEN THEY HAD NO BLOOD RETURN AND NOTICED AIR IN SYRINGE. THEY REALIZED THERE WAS A CRACK IN THE RED HUB. IT WAS LEAKING SALINE WHEN FLUSHED. PLACED A NEW PICC. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24791911 ↗
  • MalfunctionJul 8, 2025Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED BY CUSTOMER THAT THEY HAD A LEAKING PICC. IT WAS LEAKING DOWN FROM THE HUB WHEN THEY FLUSHED IT WITH SALINE. PICC REMOVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22444416 ↗
  • MalfunctionMay 9, 2025Difficult to Insert; Difficult to Insert

    IT WAS REPORTED OVER LAST SEVERAL DAYS THE TEAM HAS NOTICED THAT THE DILATORS IN THE CUSTOM PICC KIT HAVE NOT BEEN PASSING EVEN WITH DOUBLE DILATE. WHEN A NEW SINGLE PACK SEPARATE DILATOR IS ADDED, IT SLIDES IN LIKE BUTTER. I INSPECTED ONE YESTERDAY AND IT DID NOT APPEAR TO BE CRACKED, ROLLED OR TORN. MOST OF US RARELY DOUBLE DILATE WHICH PROMPTED US TO TRY SCRAPPING THE DILATOR IN THE KIT AND ADDING A NEW ONE. THEY SAID IT AT LEAST HAPPENED 4 TIMES, AND PROBABLY 4 MORE. IT WAS REPORTED THIS OCCURRED WITH EIGHT DEVICES. THIS REPORT ADDRESSES ALL EIGHT DEVICES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21997532 ↗
  • MalfunctionApr 24, 2025Defective Component; Patient-Device Incompatibility; Defective Component; Patient-Device Incompatibility

    IT WAS REPORTED THE DIAPHRAGM ON THE INTER LUMINAL WIRE HEAD WAS PREVENTING THE LUMEN FROM FLUSHING OR DRAWING. I ATTEMPTED TO FLUSH IT AND THE DIAPHRAGM EXPLODED SPRAYING ALL OF US WITH SALINE. ONCE THE WIRE WAS REMOVED THE CATHETER WAS FULLY FUNCTIONAL AND IN THE RIGHT PLACE. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21903858 ↗
  • InjuryMar 28, 2025Fluid/Blood Leak; Defective Component; Fluid/Blood Leak; Defective Component

    IT WAS REPORTED, PICC PATIENT DEVELOPED A DVT IN 24 HOURS. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: Thrombosis/Thrombus

    MAUDE report 21722132 ↗
  • MalfunctionJan 3, 2025Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED, "WE CAME ACROSS A FAULTY PICC LINE. WE DID NOT RECOGNIZE IT UNTIL THE PICC HAD BEEN PLACED AND WE WERE DOING THE FINE TUNING OF WHERE TO LEAVE THE PICC LINE. THE RED LUMEN AND ONLY THE RED LUMEN STARTED LEAKING WHEN FLUSHING. IT WAS LEAKING WHERE THE LUMEN CONNECTS TO THE BARD WINGS THAT OUR STATLOCK CONNECTS TO. WE ENDED UP REMOVING THE PICC AND REPLACING IT WITH ANOTHER DOUBLE LUMEN AND DIDN'T HAVE ANY ISSUES." NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21069130 ↗

Other Catheter, intravascular, therapeutic, long-term greater than 30 days devices

All Catheter, intravascular, therapeutic, long-term greater than 30 days devices →