TurboSENSOR™ D560110Recalls & reported problems

Parkell, Inc. · TurboSENSOR™ Ultrasonic Scaler 110 Volt · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810000520527), received between Apr 20, 2026 and Apr 20, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Temperature Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Temperature Problem1

Patient problems

  • Superficial (First Degree) Burn1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 20, 2026Temperature Problem

    ON MARCH 30, 2026, PARKELL, INC. WAS NOTIFIED OF AN ADVERSE EVENT INVOLVING AN ULTRASONIC SCALER (MANUFACTURED JULY 2025). THE HEALTHCARE PROVIDER REPORTED THAT THE DEVICE OVERHEATED DURING A PROCEDURE, RESULTING IN A PATIENT BURN. ACCORDING TO THE REPORTER, THE PATIENT DID NOT SEEK ADDITIONAL MEDICAL TREATMENT FOLLOWING THE INCIDENT. THE USER NOTED THAT THIS SPECIFIC UNIT (S/N (B)(6)) HAD BEEN RETURNED FOR SERVICE ON TWO PRIOR OCCASIONS FOR REPORTED OVERHEATING. RECORDS INDICATE THAT PREVIOUS SERVICE EVALUATIONS IDENTIFIED THE ROOT CAUSE OF THOSE INSTANCES AS AN INADEQUATE WATER SUPPLY RATHER THAN A MECHANICAL DEFECT. THE DEVICE WAS RETURNED TO THE MANUFACTURER ON APRIL 7, 2026, AND SUBMITTED TO THE ENGINEERING TEAM FOR A FORMAL EVALUATION. COMPREHENSIVE TESTING CONFIRMED THAT THE UNIT IS CURRENTLY FUNCTIONING WITHIN ALL ESTABLISHED ORIGINAL SPECIFICATIONS. THE INVESTIGATION IDENTIFIED NO HARDWARE MALFUNCTIONS OR ELECTRICAL FAULTS THAT WOULD CAUSE THE UNIT TO EXCEED SAFE TEMPERATURE THRESHOLDS UNDER NORMAL OPERATING CONDITIONS. THE ENGINEERING ASSESSMENT CONCLUDED THAT THE REPORTED OVERHEATING WAS LIKELY SECONDARY TO USER TECHNIQUE. SPECIFICALLY, THE INVESTIGATION DETERMINED THAT

    Patient problems: Superficial (First Degree) Burn

    MAUDE report 24931812 ↗

Other Scaler, Ultrasonic devices

All Scaler, Ultrasonic devices →