TurboSENSOR™ D560110Recalls & reported problems
Parkell, Inc. · TurboSENSOR™ Ultrasonic Scaler 110 Volt · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810000520527), received between Apr 20, 2026 and Apr 20, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Temperature Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Temperature Problem1
Patient problems
- Superficial (First Degree) Burn1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 20, 2026Temperature Problem
ON MARCH 30, 2026, PARKELL, INC. WAS NOTIFIED OF AN ADVERSE EVENT INVOLVING AN ULTRASONIC SCALER (MANUFACTURED JULY 2025). THE HEALTHCARE PROVIDER REPORTED THAT THE DEVICE OVERHEATED DURING A PROCEDURE, RESULTING IN A PATIENT BURN. ACCORDING TO THE REPORTER, THE PATIENT DID NOT SEEK ADDITIONAL MEDICAL TREATMENT FOLLOWING THE INCIDENT. THE USER NOTED THAT THIS SPECIFIC UNIT (S/N (B)(6)) HAD BEEN RETURNED FOR SERVICE ON TWO PRIOR OCCASIONS FOR REPORTED OVERHEATING. RECORDS INDICATE THAT PREVIOUS SERVICE EVALUATIONS IDENTIFIED THE ROOT CAUSE OF THOSE INSTANCES AS AN INADEQUATE WATER SUPPLY RATHER THAN A MECHANICAL DEFECT. THE DEVICE WAS RETURNED TO THE MANUFACTURER ON APRIL 7, 2026, AND SUBMITTED TO THE ENGINEERING TEAM FOR A FORMAL EVALUATION. COMPREHENSIVE TESTING CONFIRMED THAT THE UNIT IS CURRENTLY FUNCTIONING WITHIN ALL ESTABLISHED ORIGINAL SPECIFICATIONS. THE INVESTIGATION IDENTIFIED NO HARDWARE MALFUNCTIONS OR ELECTRICAL FAULTS THAT WOULD CAUSE THE UNIT TO EXCEED SAFE TEMPERATURE THRESHOLDS UNDER NORMAL OPERATING CONDITIONS. THE ENGINEERING ASSESSMENT CONCLUDED THAT THE REPORTED OVERHEATING WAS LIKELY SECONDARY TO USER TECHNIQUE. SPECIFICALLY, THE INVESTIGATION DETERMINED THAT
Patient problems: Superficial (First Degree) Burn
MAUDE report 24931812 ↗
FDA clearance and classification
The FDA regulates product code ELC (scaler, ultrasonic) under 21 CFR 872.4850 as a Class II device. 21 CFR 872.4850 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the TurboSENSOR™ D560110
Has the TurboSENSOR™ D560110 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00810000520527), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the TurboSENSOR™ D560110?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 20, 2026. That report lists device problem “Temperature Problem” (1); patient problem “Superficial (First Degree) Burn” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the TurboSENSOR™ D560110?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the TurboSENSOR™ D560110, and is it still sold?
The FDA's device database lists Parkell, Inc. as the company responsible for it (brand TurboSENSOR™, model D560110). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Scaler, Ultrasonic devices
- AIR-FLOW FT-230-2B-302E.M.S. Electro Medical Systems S.A. · Scaler, Ultrasonic3 recalls0 reports
- AIR-FLOW-PIEZON FT-229HF-0B-302E.M.S. Electro Medical Systems S.A. · Scaler, Ultrasonic3 recalls0 reports
- Cavitron® 81302Dentsply Professional · Scaler, ultrasonic67 reports
- Posterior CleanFlow Procedure Instrument with Matrices FG-013-00004Sonendo, Inc. · Scaler, Ultrasonic1 recall0 reports
- APM Procedure Instrument with Matrix FG-003-00011Sonendo, Inc. · Scaler, Ultrasonic1 recall0 reports
- Cavitron® 8184001Dentsply Professional · Scaler, ultrasonic49 reports
- Cavitron® 8161425Dentsply Professional · Scaler, ultrasonic44 reports
- Cavitron® 80395Dentsply Professional · Scaler, ultrasonic36 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page