IMPEDE-FX Embolization Plug IMP-FX-06Recalls & reported problems

Shape Memory Medical Inc. · IMPEDE-FX Embolization Plug, 6mm · Class 2

All models of IMPEDE-FX Embolization Plug (3)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00810041650030), received between Nov 19, 2021 and Nov 10, 2023 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Activation Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation Failure1
  • Insufficient Device Problem Information1
  • Positioning Failure1

Patient problems

  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Dyspnea1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 10, 2023Insufficient Device Problem Information; Activation Failure; Insufficient Device Problem Information; Activation Failure

    AN IMP-07 AND IMP-FX-06 DEVICE WERE USED IN A CASE IN (B)(6) TO TREAT AN AVM ON (B)(6) 2023. EMBOLIZATION WAS CONFIRMED AT THE END OF THE PROCEDURE. DURING A FOLLOW-UP VISIT ON (B)(6) 2024, IT WAS FOUND THAT THE VESSEL HAD RECANALIZED WHICH REQUIRED RE-INTERVENTION TO DELIVER ADDITIONAL EMBOLIC DEVICES (I.E., COOK NESTER COILS). THE PATIENT STATUS WAS REPORT STABLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; No Clinical Signs, Symptoms or Conditions

    MAUDE report 18116437 ↗
  • MalfunctionNov 19, 2021Positioning Failure; Positioning Failure

    A PATIENT PRESENTED WITH A PAVM (2.6 MM IN DIAMETER) WHICH HAD RECANALIZED AFTER PREVIOUSLY BEING EMBOLIZED USING COILS (NOT MANUFACTURED BY SMM). AN IMP-FX-06 DEVICE WAS CHOSEN FOR DELIVERY TO A SITE PROXIMAL TO THE PREVIOUSLY IMPLANTED COILS WITH NO SIDE BRANCHES IN THE VICINITY. DURING 4F MP CATHETER WITHDRAWAL, THE IMP-FX PLUG MIGRATED FROM THE SUB-SEGMENTAL BRANCH WHERE IT WAS DEPLOYED TO ANOTHER SUB-SUBSEGMENTAL BRANCH. IT WAS REPORTED THE PATIENT HAD EXPERIENCED DYSPNEA ONCE A DAY OR TWO AFTER THE PROCEDURE, BUT NOW HAS A STABLE STATUS.

    Patient problems: Dyspnea

    MAUDE report 12844887 ↗