Specimen Collection Swab SW0102Recalls & reported problems
Typenex Medical LLC · Specimen Collection Swab - Nasopharyngeal · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00810050851909), received between Feb 25, 2021 and Feb 25, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- Foreign Body In Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 25, 2021Break; Break
TYPENEX MEDICAL SPECIMEN COLLECTION SWABS (PRODUCT CODE: SW0102, LOT 08032) BROKE OFF WITHIN THE PATIENT'S NOSTRIL DURING SAMPLE COLLECTION. THE SWAB BROKE AT THE DESIGNATED BREAK POINT, THAT IS THE POINT ON THE SWAB THAT IS INTENDED TO BREAK INSIDE THE VIRAL TRANSPORT TUBE IN ORDER TO LEAVE THE FLOCKED HEAD INSIDE THE TUBE AND ALLOW THE TUBE TO BE CAPPED FOR TRANSPORT. THE PATIENT RECEIVED ADDITIONAL MEDICAL ATTENTION AT A LOCAL OUTPATIENT CARE FACILITY TO REMOVE THE SWAB TIP FROM THEIR NOSTRIL. A SIMILAR ISSUE WITH A DIFFERENT PATIENT HAS ALREADY BEEN REPORTED THAT OCCURRED ON THE SAME DAY AND AT THE SAME HOSPITAL.
Patient problems: Foreign Body In Patient
MAUDE report 11378456 ↗MalfunctionFeb 25, 2021Break; Break
TYPENEX MEDICAL SPECIMEN COLLECTION SWABS (PRODUCT CODE: SW0102, LOT 080320) BROKE OFF WITHIN THE PATIENT'S NOSTRIL DURING SAMPLE COLLECTION. THE SWAB BROKE AT THE DESIGNATED BREAK POINT, THAT IS THE POINT ON THE SWAB THAT IS INTENDED TO BREAK INSIDE THE VIRAL TRANSPORT TUBE IN ORDER TO LEAVE THE FLOCKED HEAD INSIDE THE TUBE AND ALLOW THE TUBE TO BE CAPPED FOR TRANSPORT. THE PATIENT RECEIVED ADDITIONAL MEDICAL ATTENTION AT A LOCAL EMERGENCY DEPARTMENT TO REMOVE THE SWAB TIP FROM THEIR NOSTRIL.
Patient problems: Foreign Body In Patient
MAUDE report 11378450 ↗
Other Applicator, Absorbent Tipped, Sterile devices
- Puritan HydraFlock 25-3317-HPuritan Medical Products · Applicator, Absorbent Tipped, Sterile1 recall0 reports
- Cultura™ 00884450491102Merit Medical Systems, Inc. · APPLICATOR, ABSORBENT TIPPED, STERILE1 recall0 reports
- Sterile Polyester Spun Swab 25 Pack 60566Steripack (usa) Limited LLC · Applicator, Absorbent Tipped, Sterile1 recall0 reports
- Cultura™ 00884450495834Merit Medical Systems, Inc. · APPLICATOR, ABSORBENT TIPPED, STERILE2 reports
- Medline MDS202105Medline Industries, Inc. · Applicator, absorbent tipped, sterile1 report
- DeRoyal 31-249Deroyal Industries, Inc. · APPLICATOR, ABSORBENT TIPPED, STERILE1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page