Tepha, Inc. · GalaFLEX 3DR Scaffold, 7.5 cm x 21.0 cm, Large Oval (Contents: 2) · Class 2 · Implant

All models of GalaFLEX 3DR (6)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00810054980056), received between Nov 2, 2023 and Jun 9, 2026 — classified as 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Patient-Device Incompatibility” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 2 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient-Device Incompatibility3
  • Incorrect, Inadequate or Imprecise Result or Readings1
  • Material Deformation1
  • Material Split, Cut or Torn1
  • Migration1

Patient problems

  • Ptosis2
  • No Clinical Signs, Symptoms or Conditions1
  • Pain1
  • Physical Asymmetry1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 9, 2026Material Split, Cut or Torn

    AS REPORTED, ON (B)(6) 2026, TWO PIECES OF GALAFLEX 3DR SCAFFOLD WERE USED BY THE SURGEON. UPON CLOSURE, IT WAS OBSERVED THAT THE RIM HAD DETACHED FROM A PORTION OF THE MESH ON ONE SIDE. IT WAS FURTHER REPORTED THAT WHEN THE MESH WAS GENTLY FOLDED, THE RIM NEARLY DETACHED. A SECOND PIECE OF MESH WAS OPENED, AND THE RIM WAS NOTED TO HAVE DETACHED AT SEVERAL LOCATIONS; DESPITE THIS, THE SURGEON OPTED TO PROCEED WITH IMPLANTATION. ADDITIONALLY, IT WAS OBSERVED THAT THE MESH WAS LESS STRETCHY AND FELT DIFFERENT. THERE WAS NO PATIENT HARM OR INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25447551 ↗
  • InjuryJun 4, 2026Patient-Device Incompatibility

    PER INFORMATION PROVIDED:\\ATTORNEY ALLEGES THAT THE PATIENT UNDERWENT BREAST AUGMENTATION REVISION SURGERY ON (b)(6) 2025, DURING WHICH A GALAFLEX 3DR MESH WAS IMPLANTED. FOLLOWING THE PROCEDURE, THE PATIENT EXPERIENCED PAIN AT THE IMPLANTATION SITE AND ON (b)(6) 2025, THE PATIENT UNDERWENT AN ADDITIONAL SURGICAL PROCEDURE TO REMOVE THE IMPLANTED MESH. AS ALLEGED, THE PATIENT EXPERIENCED ADDITIONAL SURGICAL INTERVENTION, MENTAL ANGUISH AND PAIN. ATTORNEY ALLEGES GENERAL ALLEGATIONS FOR \"PAST, PRESENT, AND FUTURE DAMAGES, INCLUDING BUT NOT LIMITED TO, MENTAL AND PHYSICAL PAIN AND SUFFERING FOR SEVERE AND PERMANENT PERSONAL INJURIES SUSTAINED BY THE PATIENT.\" IT IS ALSO ALLEGED THAT THE DEVICE WAS DEFECTIVE.\\ADDENDUM PER ADDITIONAL INFORMATION PROVIDED:\\ON (b)(6) 2025 - THE PATIENT UNDERWENT BILATERAL BREAST AUGMENTATION WITH THE IMPLANT OF GALAFLEX 3DR SCAFFOLD AND REVISION WITH THE INFRAMAMMARY FOLD SKIN EXCISION. PER OP NOTES, \"INFRAMAMMARY SKIN EXCISION WAS CARRIED OUT ON THE RIGHT SIDE. THE PREVIOUS IMPLANT WAS REMOVED BOTH IMPLANTS WERE REMOVED FROM RIGHT AND LEFT WERE NOTED TO BE INTACT GEL IMPLANTS. EXTENSIVE CAPSULECTOMY LATERALLY AND SUPERIORLY ON THE RIGHT AND LATERA

    Patient problems: Pain

    MAUDE report 25391487 ↗
  • MalfunctionNov 21, 2025Migration; Migration

    AS REPORTED, PATIENT UNDERWENT A BREAST REPAIR PROCEDURE WITH GALAFLEX IMPLANT ON (B)(6) 2025. IT WAS REPORTED THAT THE PATIENT FELT THE MESH WAS POSITIONED DIFFERENTLY ON EACH SIDE. PLACEMENT ON THE RIGHT WAS FELT TO BE POSITIONED MORE BELOW THE BREAST, IN CONTRAST TO THE LEFT, WHERE IT WAS ALONG THE SIDE. THE RIGHT SIDE IS REPORTED TO BE SAGGING SIGNIFICANTLY. PER THE PATIENT "I AM DEFINITELY NOT HAPPY WITH THE LOOK, AND THE REASON I GOT THE MESH WAS SO THAT THEY WOULDN¿T SAG¿AT LEAST NOT SO QUICKLY. THESE ARE ONLY 7 MONTHS OLD. THE MESH ON THE LEFT COMES MORE UP THE SIDE, BUT THE MESH ON THE RIGHT IS MORE UNDER THE BREAST SO THE RIGHT BREAST IS FALLING TO THE SIDE AND DOWN."

    Patient problems: Physical Asymmetry

    MAUDE report 23618677 ↗
  • InjuryJun 18, 2024Incorrect, Inadequate or Imprecise Result or Readings; Patient-Device Incompatibility; Incorrect, Inadequate or Imprecise Result or Readings; Patient-Device Incompatibility

    AS REPORTED, DURING BILATERAL BREAST REVISION AUGMENTATION SURGERY, THE PATIENT WAS IMPLANTED WITH 775 IMPLANTS AND GALAFLEX 3DR (DEVICE #1 & #2) FOR SOFT TISSUE SUPPORT ON (B)(6) 2022. IT WAS REPORTED THAT SURGEON CONFIRMS THAT THERE WAS MESH LUMPS ON BOTH SIDES. THE GALAFLEX WAS NOT SUTURED IN PLACE. THE PATIENT HAS ¿BOTTOMED OUT ¿ AND CAN STILL FEEL THE GALAFLEX "VERY EASILY.¿ IT WAS REPORTED THAT THE PATIENT AND THE SURGEON ARE CONCERNED THAT THE PRODUCT DID NOT INTEGRATE AS EXPECTED AND PLANS TO REMOVE THE MESHES SOON.

    Patient problems: Ptosis

    MAUDE report 19557231 ↗
  • InjuryNov 2, 2023Patient-Device Incompatibility; Material Deformation; Patient-Device Incompatibility; Material Deformation

    AS REPORTED, PATIENT UNDERWENT A BREAST LIFT WITH NO IMPLANT PROCEDURE IN 2021. ABOUT A YEAR LATER IN 2022, PATIENT UNDERWENT ANOTHER BREAST LIFT WITH BREAST IMPLANTS THAT WERE 400 CC. THE FOLLOWING YEAR ON (B)(6) 2023 PATIENT UNDERWENT A THIRD REVISION PROCEDURE WITH AN IMPLANT EXCHANGE TO 310 CC IMPLANTS AND A BREAST LIFT IMPLANTING THE GALAFLEX 3DR. SHORTLY AFTER THE IMPLANT OF GALAFLEX 3DR, PATIENT STARTED TO EXPERIENCE BREASTS BILATERALLY MOVING TO THE SIDE WITH VERY LITTLE TO NO SUPPORT. PATIENT REPORTS GOING TO SURGEON NUMEROUS TIMES WITH DIRECTION TO WEAR A COMPRESSION BRA AND TAPING HER BREASTS TO HOLD THEM IN PLACE. AS THE SURGEON REPORTED PATIENT'S BREAST DID NOT HOLD, IT IS MORE NOTICEABLE WITH THE RIGHT BREAST THAN THE LEFT AND THE GALAFLEX 3DR DID NOT WORK AND WILL NEED A REVISION PROCEDURE. IT WAS FURTHER REPORTED THAT THE PATIENT UNDERWENT REVISION SURGERY ON (B)(6) 2023.

    Patient problems: Ptosis

    MAUDE report 18053377 ↗

FDA clearance and classification

Cleared through 510(k) K162922 on Feb 23, 2017 (decision: Substantially Equivalent). Submitted by Tepha, Inc. as “GalaFORM 3D”. The FDA review took 128 days. FDA record ↗

The FDA regulates product code OOD (surgical film) under 21 CFR 878.3300 as a Class II device. 21 CFR 878.3300 ↗

The FDA lists this type of device as life-sustaining or life-supporting.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: To be implanted to reinforce soft tissue or bone where weakness exists. Intended to be used wherever temporary wound support is required, to reinforce soft tissues where weakness exists in the urological, gynecological, or gastrointestinal anatomy, or for the repair of hernia or other fascial defects that require the addition of a reinforcing or bridging material to obtain the desired surgical result. The absorbable protective film also may help minimize the potential for tissue attachment to the device in case of direct contact with the viscera.

Common questions about the GalaFLEX 3DR 100043-06

Has the GalaFLEX 3DR 100043-06 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00810054980056), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the GalaFLEX 3DR 100043-06?

The FDA's MAUDE database lists 5 adverse event reports for this device, received between Nov 2, 2023 and Jun 9, 2026. In those reports, the most common specific device problems are “Patient-Device Incompatibility” (3), “Incorrect, Inadequate or Imprecise Result or Readings” (1) and “Material Deformation” (1); the most common patient problems are “Ptosis” (2), “Pain” (1) and “Physical Asymmetry” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the GalaFLEX 3DR 100043-06?

None of the reports are classified as deaths, 3 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the GalaFLEX 3DR 100043-06 FDA approved?

It was cleared through 510(k) K162922 on Feb 23, 2017. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the GalaFLEX 3DR 100043-06 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.

Who makes the GalaFLEX 3DR 100043-06, and is it still sold?

The FDA's device database lists Tepha, Inc. as the company responsible for it (brand GalaFLEX 3DR, model 100043-06). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.