Prestige Coil System PRES0310CXPPLTRecalls & reported problems
Balt USA LLC · The Prestige Coil System is indicated for arterial and venous embolizations in the peripheral vasculature. It is designed for use with the Ultra Detachment Controller. · Class 2 · Implant
All models of Prestige Coil System (97)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810068567403), received between Nov 3, 2023 and Nov 3, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Migration” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
1 other recall cover devices cleared under the same FDA submission (K220699); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Recalls naming this device
- May 8, 2025Class IIOpen, Classified
Due to radiopaque (RO) marker was not visible during angiography and it was determined that the RO marker was not manufactured to specification.
Z-1989-2025 · Root cause: Vendor change control · Recall details · FDA record ↗
Most reported problems
Device problems
- Migration1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 3, 2023Migration; Migration
IT WAS REPORTED THAT: "THE COIL WAS INPLANTED IN PULMONARY ARTERY AND ONCE DETACHED IT FLEW OUT OF PLACE. THE COIL HAD TO BE SNARED AND REMOVED FROM THE PATIENT. WE BELIEVE THAT THE PUSHING WIRE AFTER DETACHMENT GRABBED THE COIL PACK AND HELP DISLODGE THE COIL FROM PLACEMENT. WAS INDICATED THAT "TREAD TECH" IS NEEDED ON THE 3MM COILS FOR BETTER GRIPPING OF THE VESSEL." INCIDENT REPORT FORM SUBMITTED FOR THIS COMPLAINT INDICATES THAT NO PATIENT INJURY WAS SUSTAINED. (B)(6) 2023, ADDITIONAL INFORMATION PROVIDED BY ISSUER. "DID THE IMPLANT COMPLETELY MIGRATE OUT OF THE TREATMENT SITE OR DID A SEGMENT OF THE IMPLANT HERNIATE INTO THE PARENT VESSEL? THE ENTIRE COIL MIGRATED. IS MY UNDERSTANDING CORRECT: THE DELIVERY PUSHER INTERACTED WITH THE COIL MASS AFTER A SUCCESSFUL DETACHMENT, CAUSING THE IMPLANT TO MOVE OUT OF THE TREATMENT SITE? THAT IS CURRENT BELIEF."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18066316 ↗
FDA clearance and classification
Cleared through Special 510(k) K220699 on Apr 8, 2022 (decision: Substantially Equivalent). Submitted by Bait USA, LLC as “Prestige Coil System”. The FDA review took 29 days. FDA record ↗
The FDA regulates product code KRD (device, vascular, for promoting embolization) under 21 CFR 870.3300 as a Class II device. 21 CFR 870.3300 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K220699. One submission often covers many models, so check the product and lot details in each record.
- Z-1042-2024 · Jan 3, 2024 · Open, ClassifiedThe Prestige Coil System is a product family of embolic coils with associated delivery system components. These devices are angiographically delivered through the vasculature to em
Common questions about the Prestige Coil System PRES0310CXPPLT
Has the Prestige Coil System PRES0310CXPPLT been recalled?
Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1989-2025 (Class II), began on May 8, 2025: Due to radiopaque (RO) marker was not visible during angiography and it was determined that the RO marker was not manufactured to specification. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
What problems have been reported with the Prestige Coil System PRES0310CXPPLT?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Nov 3, 2023. That report lists device problem “Migration” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Prestige Coil System PRES0310CXPPLT?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Prestige Coil System PRES0310CXPPLT FDA approved?
It was cleared through Special 510(k) K220699 on Apr 8, 2022. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the Prestige Coil System PRES0310CXPPLT MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the Prestige Coil System PRES0310CXPPLT, and is it still sold?
The FDA's device database lists Balt USA LLC as the company responsible for it (brand Prestige Coil System, model PRES0310CXPPLT). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Device, Vascular, For Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization117 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page