Azur Detachable Framing Coil 45-680820Recalls & reported problems
Microvention, Inc. · Azur · Class 2 · Implant
All models of Azur Detachable Framing Coil (7)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00810170017742), received between Mar 22, 2019 and Jan 14, 2025 — classified as 1 injury, 4 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component4
- Device-Device Incompatibility2
- Physical Resistance/Sticking1
- Premature Separation1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 14, 2025Physical Resistance/Sticking; Premature Separation; Physical Resistance/Sticking; Premature Separation
AS REPORTED: DURING SPLENIC ARTERY ANEURYSM EMBOLIZATION, THE PHYSICIAN NOTICED CONSIDERABLE RESISTANCE AS HE ADVANCED THIS COIL THROUGH THE MICROCATHETER. THIS WAS NOT THE FIRST COIL OR LAST COIL TO BE ADVANCED THROUGH THIS SYSTEM. THE PHYSICIAN RECAPTURED THE COIL TO FLUSH THE SYSTEM AND TRY AGAIN. THE COIL WAS RETRACTED INTO THE COIL SHEATH, AFTER THE COIL WAS APPROXIMATELY HALFWAY INTO THE COIL SHEATH. THE COIL DETACHED FROM THE PUSHER WIRE, LEAVING THE COIL HALF INSIDE THE MICROCATHETER AND HALFWAY OUT OF IT. THE COIL WAS PULLED FROM THE CATHETER AND DISCARDED. ADDITIONAL COILS WERE ADVANCED AFTER THIS POINT WITH NO FURTHER RESISTANCE ISSUES. THE COIL MUST HAVE BROKE SOME TIME AFTER THE PROXIMAL END WAS IN THE PROTECTIVE SHEATH BECAUSE WHEN THE COIL WAS PULLED OUT AND AWAY FROM THE MICROCATHETER HUB, THE COIL REMAINED HALF INSIDE AND HALF OUTSIDE OF THE MICROCATHETER. THERE WAS APPROXIMATELY 10- 15 CM OF COIL OUTSIDE OF THE MICROCATHETER, ALLOWING FOR THE PHYSICIAN TO GRAB IT WITH HIS HAND AND REMOVE IT FROM THE MICROCATHETER NO PATIENT INJURY REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21153252 ↗InjuryApr 20, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING AN EMBOLIZATION PROCEDURE FOR A PSEUDO-ANEURYSM, THE DELIVERY PUSHER OF AN EMBOLIZATION COIL IMPLANT SEPARATED INTO TWO PIECES. THE PHYSICIAN FLUSHED THE COIL INTO POSITION AND ATTEMPTED TO SNARE THE PART OF THE PUSHER STILL INSIDE OF THE PATIENT. PART OF THE COIL WAS REMOVED SUCCESSFULLY, HOWEVER A PORTION REMAINS WITHIN THE PATIENT. ADDITIONAL FLUORO TIME WAS NEEDED TO TRY TO RETRIEVE THE COIL. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11691608 ↗MalfunctionApr 1, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A PORTAL VEIN EMBOLIZATION, AN EMBOLIZATION COIL IMPLANT DETACHED IN THE MICROCATHETER DURING RETRACTION. THE COIL WAS REMOVED FROM THE PATIENT. THERE WAS NO REPORTED PATIENT INJURY OR INTERVENTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11600697 ↗MalfunctionMar 22, 2019Detachment of Device or Device Component; Device-Device Incompatibility; Detachment of Device or Device Component; Device-Device Incompatibility
IT WAS REPORTED THAT RESISTANCE WAS ENCOUNTERED DURING ADVANCEMENT OF THE COIL IN THE CATHETER. DURING REMOVAL, THE COIL DETACHED INSIDE THE CATHETER. THE COIL WAS REMOVED IN ITS ENTIRETY TOGETHER WITH THE CATHETER. THERE WAS NO REPORTED PATIENT INJURY OR INTERVENTION. THE PATIENT WAS REPORTED TO BE STABLE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8445502 ↗MalfunctionMar 22, 2019Detachment of Device or Device Component; Device-Device Incompatibility; Detachment of Device or Device Component; Device-Device Incompatibility
IT WAS REPORTED THAT RESISTANCE WAS ENCOUNTERED DURING ADVANCEMENT OF THE COIL IN THE CATHETER. DURING REMOVAL, THE COIL DETACHED INSIDE THE CATHETER. THERE WAS NO REPORTED PATIENT INJURY OR INTERVENTION. THE PATIENT WAS REPORTED TO BE STABLE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8445444 ↗
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization115 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page