Lantern Surgical Assistant (LSA) 406000-02Recalls & reported problems

Orthalign, Inc. · Packaged Assembly, Nav Unit, LSA · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
13
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 00810832031567), received between Sep 2, 2022 and Nov 4, 2025 — classified as 13 malfunctions.

The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (9 reports).

2 other recalls cover devices cleared under the same FDA submission (K200892); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 4 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Incorrect, Inadequate or Imprecise Result or Readings9
  • Delayed Program or Algorithm Execution1
  • Expiration Date Error1
  • Improper or Incorrect Procedure or Method1
  • Inadequate User Interface1
  • Incorrect Measurement1

Patient problems

  • No Clinical Signs, Symptoms or Conditions12
  • Joint Laxity1

Recent adverse event reports

The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 4, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    WHEN TIBIA REGISTRATION WAS PERFORMED, IT WAS SET TO VARUS, BUT THERE WAS A SUSPICION OF VALGUS WHEN VISUALLY OBSERVED. WHEN THE ALIGNMENT WAS CHECKED MANUALLY, IT WAS CLEARLY VALGUS. TRIED TIBIAL REGISTRATION AGAIN, BUT THE SAME ISSUE OCCURRED. SURGERY WAS COMPLETED WITH KNEEALIGN. THE SURGERY WAS PERFORMED ON THE RIGHT LEG. THE COMPLAINT EVENT WAS FOUND BEFORE THE LANTERN SETTING AND THE RESECTION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23469650 ↗
  • MalfunctionJul 8, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    THE UNIT PRODUCED WRONG NUMBERS ON DISTAL FEMUR CUT. THE SURGEON SET THE VALUES TO 4 DEGREES OF FLEXION AND 0 DEGREES V/V ON DISTAL FEMUR CUT, BUT AFTER HE REGISTERED, THE NUMBERS CHANGED TO 1 DEGREE EXTENSION AND 0.5 DEGREES VALGUS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22438909 ↗
  • MalfunctionMar 11, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    FEMUR REGISTRATOIN WAS COMPLETED BUT THE VALUES ON THE SUMMARY SCREEN ON THE NEXT PAGE DID NOT MATCH THE REGISTRATION VALUES. THE NUMBERS CHANGED WHEN ADVANCING TO THE REGISTRATION SCREEN. THE CASE WAS COMPLETED WITH MANUAL INSTRUMENTATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21577034 ↗
  • MalfunctionMar 11, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    FEMUR REGISTRATION WAS COMPLETED BUT THE VALUES ON THE SUMMARY SCREEN ON THE NEXT PAGE DID NOT MATCH THE REGISTRATION VALUES. THE NUMBERS CHANGED WHEN ADVANCING TO THE REGISTRATION SCREEN. THE CASE WAS COMPLETED WITH MANUAL INSTRUMENTATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21576541 ↗
  • MalfunctionMar 5, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    NAVIGATION UNIT DISPLAYED 2.5 DEGRESS FLEXION ON FEMUR BUT THEN WHEN ADVANCED TO NEXT SCREEN IT SHOWED 1 DEGREE OF FLEXION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21525997 ↗
  • MalfunctionMar 3, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    SURGEON WAS HAVING DIFFICULTY WITH THE NAVIGATION READING TAS NEEDING LESS FLEXION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21507202 ↗
  • MalfunctionDec 26, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    SURGEON WAS HAVING DIFFICULTY WITH THE NAVIGATION READING TAS NEEDING LESS FLEXION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21020969 ↗
  • MalfunctionNov 5, 2024Expiration Date Error; Expiration Date Error

    AN EXPIRED NAVIGATION UNIT WAS USED IN A PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20610786 ↗
  • MalfunctionSep 23, 2024Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method

    AN EXPIRED UNIT WAS UNKNOWINGLY USED IN A PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20279236 ↗
  • MalfunctionAug 22, 2024Inadequate User Interface; Delayed Program or Algorithm Execution; Inadequate User Interface; Delayed Program or Algorithm Execution

    CUSTOMER REPORTED THAT THE NAVIGATION UNIT WOULD NOT CALIBRATE. UPON RECEIPT OF THE UNIT AND INVESTIGATION OF THE COMPLAINT, IT WAS FOUND THAT THE LOG SHOWS THAT BT CALIBRATION WAS SKIPPED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20034289 ↗
  • MalfunctionAug 16, 2023Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    DISTAL FEMUR WAS CALIBRATED AND REGISTERED WITHOUT INCIDENT OR CONCERN. DISTAL FEMORAL CUT WAS MADE AND PROGRESSED TO TIBIA WITHOUT INCIDENT. IT WAS OBSERVED THAT THE EXTENSION GAP WAS EXTREMELY TIGHT. AN ADDITION 4MM WAS RESECTED OFF THE TIBIA AND AN ADDITION 2MM OFF FEMUR. GUIDE PINS AND SPACER BLACK WERE OBSERVED TO BE DIVERGING INTO EACH OTHER.

    Patient problems: Joint Laxity

    MAUDE report 17560690 ↗
  • MalfunctionFeb 20, 2023Incorrect Measurement; Incorrect Measurement

    POSSIBLE INACCURATE MEASUREMENT -- IT WAS REPORTED THAT THE USER (SURGEON) DID NOT TRUST THE DEGREES OF VARUS THE DEVICE WAS READING FOR THE DISTAL FEMUR. BELIEVED THAT THE NUMBERS SHOULD HAVE BEEN FOR THE OPPOSITE SIDE BUT THE UNIT WAS SET TO THE CORRECT SIDE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16402014 ↗
  • MalfunctionSep 2, 2022Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT "THE 14 AND 14 AT THE BOTTOM ARE INCORRECT BASED ON THE 13 IN THE MIDDLE." NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15352771 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K200892. One submission often covers many models, so check the product and lot details in each record.

  • Z-1629-2026 · Feb 10, 2026 · Open, Classified
    Drill Plate, Ortho Dev. Trimax - Pegged, PREF Size 1 -5 REF:402566 component Lantern Knee System
  • Z-1630-2026 · Feb 10, 2026 · Open, Classified
    Drill Plate, Ortho Dev. Trimax - Pegged, PREF Size 6-7 REF:402567 component Lantern Knee System

Other Orthopedic Stereotaxic Instrument devices

All Orthopedic Stereotaxic Instrument devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page