Sofia 6F-131cm STR DA6131STRecalls & reported problems
Microvention, Inc. · Stroke Access · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00812636020846), received between Jul 1, 2021 and Jul 1, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Deformation Due to Compressive Stress” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Deformation Due to Compressive Stress1
Patient problems
- Vascular Dissection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 1, 2021Deformation Due to Compressive Stress; Deformation Due to Compressive Stress
IT WAS REPORTED THAT A MALE PATIENT WITH A LEFT M1 THROMBOEMBOLIC OCCLUSION WAS TREATED BY ENDOVASCULARLY. AN 8F GUIDE CATHETER WAS PLACED IN THE MODERATELY ELONGATED LEFT CERVICAL ICA THAT HAD SHOWN ATHEROSCLEROTIC WALL CHANGES ON THE INITIAL CT. THE PROXIMAL SURFACE OF THE CLOT WAS EASILY REACHED WITH THE SOFIA DIRECT ASPIRATION, HOWEVER WAS NOT SUFFICIENT. THE CLOT COULD BE PASSED WITH A MICROCATHETER, WIRE AND STENT RETRIEVER. STANDARD RETRIEVAL UNDER CONTINUOUS ASPIRATION ON THE SOFIA DISLODGED THE CLOT, HOWEVER, IT WAS NOT POSSIBLE TO FULLY RETRIEVE THE STENT INTO THE SOFIA. DURING THE ATTEMPTS TO RETRIEVE, INTENSE AXIAL LOAD WAS TRANSMITTED TO THE SOFIA RESULTING IN RESISTANCE DURING ADVANCEMENT AND RETRACTION ATTEMPTS AND THE DEVICE BECOMING DAMAGED. THE SOLUTION WAS THAT THE THROMBX WAS DISMANTLED, ITS INTRODUCTION WIRE CUT OUTSIDE THE PATIENT, THE PROXIMAL BASKET AND ALL CATHETERS WERE REMOVED. THE INTRODUCER WIRE WAS THEN USED TO DELIVER A NEW MICROCATHETER AND A DIFFERENT INTERMEDIATE CATHETER WHICH ALLOW TO RETRIEVE THE DISTAL BASKET TOGETHER WITH THE CLOT, RESULTING IN A TICI 3 RECANALIZATION. THE CERVICAL ICA SHOWED A DISSECTION IN A LOCATION THAT WAS EXPOSED TO THE
Patient problems: Vascular Dissection
MAUDE report 12104381 ↗
Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H74908526031Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page