Skip to content

OsseoGuard Flex OGF1520Recalls & reported problems

Collagen Matrix, Inc. · Resorbable Collagen Membrane for Dental Surgery 15mm x 20mm · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00813954020358), received between Dec 12, 2025 and Dec 12, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Osseointegration Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Osseointegration Problem1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 12, 2025Osseointegration Problem; Osseointegration Problem

    THIS ADVERSE EVENT OCCURRED OUTSIDE OF THE U.S. HOWEVER, AS THERE IS A SIMILARLY MARKETED DEVICE IN THE U.S., AN MDR IS BEING FILED. COMPLAINT RECEIVED THROUGH CLINICAL DATA COLLECTION. AN OSSEOGUARD FLEX MEMBRANE WAS UTILIZED DURING A PROCEDURE FOR FILLING OF BONE DEFECTS AFTER ROOT RESECTION, CYSTECTOMY OR REMOVAL OF RETAINED TEETH ON (B)(6) 2023. THE CLINICIAN REPORTED LOSS OF BONE GRAFT MATERIAL. THE MEMBRANE WAS HYDRATED PRIOR TO PLACEMENT WITH STERILE SALINE. BIO-OSS BONE GRAFT MATERIAL WAS ALSO USED. SUTURES WERE USED TO STABILIZE THE MEMBRANE IN PLACE 5.0 CORALENE. PRIMARY CLOSURE WAS ACHIEVED. NO OTHER PRODUCTS WERE USED, NO COMPLICATIONS OCCURRED DURING IMPLANTATION AND NO OTHER CONCOMITANT MEDICAL TREATMENT WAS PERFORMED. POST-OPERATIVE INSTRUCTIONS INCLUDED ANTIMICROBIAL ORAL RINSE PERIO-AID. FOLLOW UP VISIT OCCURRED (B)(6) 2023 FOR IMPLANT PLACEMENT. WOUND HEALING UNEVENTFUL. ADVERSE EVENT OBSERVED: LOSS OF BONE GRAFT MATERIAL. SURGICAL/MEDICAL INTERVENTION WAS REQUIRED, EXTRA BONE GRAFT AND MEMBRANE. PERIODONTAL DEFECT REGENERATION WAS SUCCESSFUL. DENTAL IMPLANT WAS PLACED. MEMBRANE RESORPTION ASSESSMENT: 0 - MEMBRANE NOT VISUALLY PRESENT. POST-OPERATIVE INSTRUCTIONS

    Patient problems: Insufficient Information

    MAUDE report 23794923 ↗

FDA clearance and classification

The FDA regulates product code NPL (barrier, animal source, intraoral) under 21 CFR 872.3930 as a Class II device. 21 CFR 872.3930 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: An animal source dental barrier is an animal-derived material device, such as collagen, intended to aid in guided tissue/bone regeneration procedures and to act as a stable barrier for the containment of bone graft materials when placed around implants.

Common questions about the OsseoGuard Flex OGF1520

Has the OsseoGuard Flex OGF1520 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00813954020358), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the OsseoGuard Flex OGF1520?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Dec 12, 2025. That report lists device problem “Osseointegration Problem” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the OsseoGuard Flex OGF1520?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the OsseoGuard Flex OGF1520 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the OsseoGuard Flex OGF1520, and is it still sold?

The FDA's device database lists Collagen Matrix, Inc. as the company responsible for it (brand OsseoGuard Flex, model OGF1520). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Barrier, Animal Source, Intraoral devices

All Barrier, Animal Source, Intraoral devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page