MiSeqDx Instrument 15036706Recalls & reported problems

Illumina, Inc. · The Illumina MiSeqDx is a sequencing instrument that measures fluorescence signals of labeled nucleotides through the use of instrument specific reagents and flow cells (MiSeqDx Universal Kit 1.0), imaging hardware, and data analysis software. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
2

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00816270020002), received between Sep 10, 2025 and Sep 10, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

2 FDA recall records name this device's identifier.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Apr 5, 2023Class IICompleted

    Cybersecurity vulnerability concerning the software used for sequencing instruments.

    Z-1977-2023 · Root cause: Software Manufacturing/Software Deployment · Recall details · FDA record ↗

  2. May 3, 2022Class IICompleted

    cybersecurity vulnerability

    Z-1259-2022 · Root cause: Software in the Use Environment · Recall details · FDA record ↗

Most reported problems

Device problems

  • Insufficient Device Problem Information1

Patient problems

  • Burn(s)1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjurySep 10, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    THE IMPACTED PRODUCT IS THE MISEQ SYSTEM, WHICH IS A RESEARCH USE ONLY (RUO) PRODUCT. THIS PRODUCT IS LIKE OR SIMILAR TO THE MISEQDX INSTRUMENT IN VITRO DIAGNOSTIC (IVD). THE SEQUENCING BY SYNTHESIS (SBS) CHEMISTRY FOR THE RUO INSTRUMENT IS SIMILAR TO THE IVD INSTRUMENT, THEREFORE, THIS EVENT IS BEING REPORTED AS AN MDR. NOTE: INDIVIDUAL FORMULATIONS MAY DIFFER SOMEWHAT. THE MISEQDX INSTRUMENT IS INTENDED FOR TARGETED SEQUENCING OF DNA LIBRARIES FROM HUMAN GENOMIC DNA EXTRACTED FROM PERIPHERAL WHOLE BLOOD OR FORMALIN-FIXED, PARAFFIN-EMBEDDED (FFPE) TISSUE, WHEN USED WITH IN VITRO DIAGNOSTIC (IVD) ASSAYS PERFORMED ON THE INSTRUMENT. THE MISEQDX INSTRUMENT IS NOT INTENDED FOR WHOLE GENOME OR DE NOVO SEQUENCING. THE MISEQDX INSTRUMENT IS TO BE USED WITH REGISTERED AND LISTED, CLEARED, OR APPROVED IVD REAGENTS AND ANALYTICAL SOFTWARE. ON AUGUST 20, 2025, AN ILLUMINA FIELD SAFETY ENGINEER (FSE) WAS AT THE CUSTOMER SITE TO PERFORM OPTICAL ADJUSTMENT WHILE INSTALLING A NEW SOLID STATE DRIVE (SSD). DURING INSTALLATION, THE FSE OBSERVED SMOKE AND BROWN DISCOLORATION ON THE CABLE AS WELL AS A BURNT HOLE IN THE BLACK OUT CLOTH. THE SOURCE WAS TRACED TO A FLOW SENSOR CABLE. THE CABLE WAS THEN

    Patient problems: Burn(s)

    MAUDE report 23023144 ↗

Other High Throughput Dna Sequence Analyzer devices

All High Throughput Dna Sequence Analyzer devices →