PhotonGuide Wide / Flat (REF 104015)Recalls & reported problems
Stryker Corporation · Illuminator, Wide/Flat · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00816728020080), received between Jul 26, 2023 and Dec 6, 2024 — classified as 7 malfunctions.
The most frequently reported specific device problem is “Overheating of Device” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Overheating of Device6
- Melted5
- Fracture1
Patient problems
- No Clinical Signs, Symptoms or Conditions7
- Insufficient Information1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 6, 2024Melted; Overheating of Device; Melted; Overheating of Device
IT WAS REPORTED THAT THE PRODUCT MELTED.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 20868282 ↗MalfunctionFeb 27, 2024Melted; Overheating of Device; Melted; Overheating of Device
PER THE SURGEON, DURING A PROCEDURE THE PHOTONGUIDE MELTED WHILE BEING USED WITH A XENON LIGHT SOURCE. PER THE SURGEON THERE WAS NO INJURY TO THE PATIENT OR USER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A SURGICAL DELAY; NO MEDICAL INTERVENTION OR ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18790426 ↗MalfunctionFeb 27, 2024Melted; Overheating of Device; Melted; Overheating of Device
PER THE SURGEON, DURING A PROCEDURE THE PHOTONGUIDE MELTED WHILE BEING USED WITH A XENON LIGHT SOURCE. PER THE SURGEON THERE WAS NO INJURY TO THE PATIENT OR USER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A SURGICAL DELAY; NO MEDICAL INTERVENTION OR ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18790259 ↗MalfunctionFeb 27, 2024Melted; Overheating of Device; Melted; Overheating of Device
PER THE SURGEON, DURING A PROCEDURE THE PHOTONGUIDE MELTED WHILE BEING USED WITH A XENON LIGHT SOURCE. PER THE SURGEON THERE WAS NO INJURY TO THE PATIENT OR USER. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A SURGICAL DELAY; NO MEDICAL INTERVENTION OR ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18788846 ↗MalfunctionOct 23, 2023Fracture; Fracture
THIS REPORT SUMMARIZES 2 MALFUNCTION EVENTS IN WHICH THE DEVICE OR CUTTING ACCESSORY FRACTURED. 2 EVENTS HAD PATIENT INVOLVEMENT; NO PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17990687 ↗MalfunctionOct 23, 2023Melted; Overheating of Device; Melted; Overheating of Device
THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT IN WHICH THE DEVICE REPORTEDLY OVERHEATED AND MELTED. 1 EVENT HAD PATIENT INVOLVEMENT; NO PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17986905 ↗MalfunctionJul 26, 2023Overheating of Device; Overheating of Device
THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT IN WHICH THE DEVICE REPORTEDLY OVERHEATED. 1 EVENT HAD PATIENT INVOLVEMENT; NO PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17397060 ↗
FDA clearance and classification
The FDA regulates product code FSZ (light, surgical, carrier) under 21 CFR 878.4580 as a Class II device. 21 CFR 878.4580 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the PhotonGuide Wide / Flat
Has the PhotonGuide Wide / Flat been recalled?
No FDA recall record in our data names this exact device identifier (DI 00816728020080), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the PhotonGuide Wide / Flat?
The FDA's MAUDE database lists 7 adverse event reports for this device, received between Jul 26, 2023 and Dec 6, 2024. In those reports, the most common specific device problems are “Overheating of Device” (6), “Melted” (5) and “Fracture” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the PhotonGuide Wide / Flat?
None of the reports are classified as deaths, 0 as injuries and 7 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the PhotonGuide Wide / Flat FDA approved?
Devices of this type (product code FSZ) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Stryker Corporation.
Who makes the PhotonGuide Wide / Flat, and is it still sold?
The FDA's device database lists Stryker Corporation as the company responsible for it (brand PhotonGuide, model Wide / Flat). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Light, Surgical, Carrier devices
- PhotonGuide Wide / FlatStryker Corporation · Light, Surgical, Carrier4 reports
- PhotonGuide AdaptStryker Corporation · Light, Surgical, Carrier4 reports
- PhotonGuide Narrow / FlatStryker Corporation · Light, Surgical, Carrier2 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page