PhotonGuide Narrow / FlatRecalls & reported problems
Stryker Corporation · Illuminator, Narrow/Flat · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00816728021650), received between Mar 31, 2020 and Apr 6, 2020 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
- Fracture1
- Overheating of Device1
Patient problems
- No Consequences Or Impact To Patient2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 6, 2020Fracture; Overheating of Device; Fracture; Overheating of Device
IT WAS REPORTED THAT PRIOR TO A SURGICAL PROCEDURE AT THE USER FACILITY, THE PRODUCT BROKE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; THERE WERE NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 9928476 ↗MalfunctionMar 31, 2020Break; Break
IT WAS REPORTED THAT DURING A SURGICAL PROCEDURE AT THE USER FACILITY, THE DEVICE BROKE IN HALF. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; THERE WERE NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9907819 ↗
FDA clearance and classification
The FDA regulates product code FSZ (light, surgical, carrier) under 21 CFR 878.4580 as a Class II device. 21 CFR 878.4580 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the PhotonGuide Narrow / Flat
Has the PhotonGuide Narrow / Flat been recalled?
No FDA recall record in our data names this exact device identifier (DI 00816728021650), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the PhotonGuide Narrow / Flat?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 31, 2020 and Apr 6, 2020. In those reports, the most common specific device problems are “Break” (1), “Fracture” (1) and “Overheating of Device” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the PhotonGuide Narrow / Flat?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the PhotonGuide Narrow / Flat FDA approved?
Devices of this type (product code FSZ) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Stryker Corporation.
Who makes the PhotonGuide Narrow / Flat, and is it still sold?
The FDA's device database lists Stryker Corporation as the company responsible for it (brand PhotonGuide, model Narrow / Flat). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Light, Surgical, Carrier devices
- PhotonGuide Wide / FlatStryker Corporation · Light, Surgical, Carrier7 reports
- PhotonGuide Wide / FlatStryker Corporation · Light, Surgical, Carrier4 reports
- PhotonGuide AdaptStryker Corporation · Light, Surgical, Carrier4 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page