HydroSoft Helical 100154H2HS-V-A2Recalls & reported problems

Microvention, Inc. · V-Trak · Class 2 · Implant

All models of HydroSoft Helical (21)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00816777022844), received between Apr 15, 2020 and Aug 13, 2025 — classified as 1 injury, 4 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component2
  • Adverse Event Without Identified Device or Use Problem1
  • Device Markings/Labelling Problem1
  • Device-Device Incompatibility1
  • Difficult to Remove1
  • Entrapment of Device1
  • Premature Separation1
  • Separation Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Consequences Or Impact To Patient2
  • Stroke/CVA1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SEE H11 FOR INVESTIGATION CONCLUSION.

    Patient problems: Stroke/CVA

    MAUDE report 22800873 ↗
  • MalfunctionDec 13, 2024Premature Separation; Premature Separation

    IT WAS REPORTED THAT DURING THE COILING OF AN A. MEDIA-ANEURYSM IT WAS NOT POSSIBLE TO PUSH THE COIL THROUGH THE MICROCATHETER AND THEN THE COIL TORN OFF IN THE MICROCATHETER. NO REPORTED INJURY TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20922028 ↗
  • MalfunctionDec 15, 2021Detachment of Device or Device Component; Device-Device Incompatibility; Detachment of Device or Device Component; Device-Device Incompatibility

    IT WAS REPORTED THAT DURING TREATMENT OF A DACA ANEURYSM, AN EMBOLIZATION COIL IMPLANT ENCOUNTERED RESISTANCE DURING ADVANCEMENT AND DETACHED WITHIN THE MICROCATHETER DURING RETRACTION. THE COIL THE WAS REMOVED IN ITS ENTIRETY ALONG WITH THE MICROCATHETER. THERE WAS NO REPORTED PATIENT INJURY OR INTERVENTION

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13007930 ↗
  • MalfunctionMay 1, 2020Device Markings/Labelling Problem; Device Markings/Labelling Problem

    IT WAS REPORTED THAT AFTER UNPACKING THE DEVICE, THE ZEBRA MARKS AT THE PROXIMAL END OF THE PUSHER COIL WERE NOTED TO BE MISSING FROM THE DEVICE. THE DEVICE WAS NOT USED IN THE PATIENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10018057 ↗
  • InjuryApr 15, 2020Entrapment of Device; Difficult to Remove; Separation Failure; Detachment of Device or Device Component; Entrapment of Device; Difficult to Remove; Separation Failure; Detachment of Device or Device Component

    IT WAS REPORTED THAT AFTER PLACEMENT OF AN EMBOLIZATION COIL IN AN INTERNAL CAROTID ARTERY ANEURYSM, THE COIL COULD NOT BE DETACHED DESPITE SEVERAL ATTEMPTS. DURING REMOVAL OF THE COIL, A PREVIOUSLY PLACED COIL WAS DISLODGED. A MICROCATHETER AND A STENT RETRIEVER WERE USED TO RETRIEVE THE DISLOCATED COIL FROM THE PATIENT. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9961777 ↗

Other DEVICE, NEUROVASCULAR EMBOLIZATION devices

All DEVICE, NEUROVASCULAR EMBOLIZATION devices →