V-Trak 7210-0254-A2Recalls & reported problems

Microvention, Inc. · HydroSoft Advanced · Class 2 · Implant

All models of V-Trak (75)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00816777023100), received between Nov 22, 2021 and May 20, 2025 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1
  • Separation Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 20, 2025Separation Problem; Separation Problem

    AS REPORTED: DR. WAS PERFORMING A COILING OF AN MCA BIFURCATION ANEURYSM. THE 2.5/4CM HYDROSOFT WAS INSERTED BUT WOULD NOT DETACH AFTER PLACEMENT. DR. TRIED TO RECAPTURE THE HYDROSOFT COIL BACK INTO THE MICROCATHETER. DURING THE ATTEMPTED RECAPTURING OF THE COIL, IT DETACHED BUT LEFT A PORTION OF THE PROXIMAL END OF THE COIL IN THE PARENT VESSEL. DR. HAD TO PLACE A STENT TO SECURE THE PROXIMAL END OF THE COIL AGAINST THE VESSEL WALL. CASE WAS COMPLETED WITH THE ANEURYSM BEING COILED AND A STENT WAS PLACED TO SECURE COIL AGAINST VESSEL WALL. PATIENT WOKE UP NEUROLOGICALLY INTACT AND WAS FINE POST OP 24 HOURS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22057476 ↗
  • MalfunctionNov 22, 2021Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A COIL EMBOLIZATION PROCEDURE OF AN ANEURYSM, THE PUSHER UNINTENTIONALLY DETACHED IN THE MICROCATHETER AFT DEPLOYMENT. THE "ENITIRE" COIL WAS REMOVED COIL FROM THE PATIENT. ANOTHER COIL WAS USED TO SUCCESSFULLY COMPLETE THE CASE. THE PATIENT IS FINE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12858515 ↗

Other Device, Vascular, for Promoting Embolization devices