HydroFrame 10 Advanced 101036HFRM-V-A2Recalls & reported problems
Microvention, Inc. · V-Trak · Class 2 · Implant
All models of HydroFrame 10 Advanced (22)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00816777023612), received between Aug 20, 2020 and Aug 20, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component1
- Difficult to Remove1
- Stretched1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 20, 2020Difficult to Remove; Stretched; Detachment of Device or Device Component; Difficult to Remove; Stretched; Detachment of Device or Device Component
IT WAS REPORTED THAT COIL EMBOLIZATION WAS PERFORMED AS TREATMENT FOR A RIGHT INTERNAL CAROTID PCOM ARTERY ANEURYSM. AN ATTEMPT WAS MADE TO REPOSITION THE COIL AND DURING RETRACTION, THE COIL STRETCHED AND THEN UNEXPECTEDLY DETACHED. THE DISTAL END OF THE IMPLANT COIL REMAINED IN THE ANEURYSM AND APPROXIMATELY 90% OF THE IMPLANT COIL WAS OUTSIDE THE ANEURYSM. ATTEMPTS WERE MADE TO RETRIEVE THE DETACHED COIL WITH A SNARE DEVICE, BUT THEY WERE UNSUCCESSFUL. THE IMPLANT COIL WAS STRETCHED AND THINNED IN ITS PROXIMAL SEGMENT AS A RESULT OF THE COIL RETRIEVAL ATTEMPTS. THE STRETCHED SEGMENT OF COIL OUTSIDE THE ANEURYSM WAS PRESSED AGAINST THE WALL OF THE INTERNAL AND PRIMITIVE STRAIGHT CAROTID ARTERIES, THE BRACHIOCEPHALIC TRUNK, AND THE AORTA DOWN TO THE COMMON FEMORAL ARTERY. THE PATIENT WAS PLACED ON HEPARIN POST-OPERATIVELY. THERE WAS NO REPORTED PATIENT INJURY AND THERE WERE NO CLINICAL COMPLICATIONS FOR THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10429336 ↗
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization115 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.