V-Trak 7110-0405-A2Recalls & reported problems

Microvention, Inc. · HydroFrame 10 Advanced · Class 2 · Implant

All models of V-Trak (75)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00816777023650), received between Nov 7, 2018 and Mar 31, 2026 — classified as 4 injuries.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Detachment of Device or Device Component1
  • Difficult to Advance1
  • Unraveled Material1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Aneurysm1
  • Neuropathy1
  • Thrombosis/Thrombus1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 31, 2026Unraveled Material; Difficult to Advance

    IT WAS REPORTED THAT THE EMBOLIZATION COIL WAS USED TO TREAT A PATIENT WITH AN ACOMM ANEURYSM. REPORTEDLY, IT WAS DIFFICULT TO ADVANCE THE COIL AND THE PHYSICIAN ATTEMPTED TO PULL THE COIL BACK INTO THE SHEATH WHEN THE COIL STARTED TO UNRAVEL AND WOULD NOT GO BACK INTO THE SHEATH. THE COIL WAS REMOVED FROM THE PATIENT AND THE CASE WAS ABORTED AS THE COIL COULD NOT BE PLACED IN THE ANEURYSM. NO COILS WERE IMPLANTED DURING THE CASE. REPORTEDLY, VESSEL ANATOMY WAS THE MAIN REASON WHY PHYSICIAN WAS UNABLE TO TREAT THE ANEURYSM. AT THE END OF PROCEDURE, THE PATIENT WAS THE SAME AS PRE PROCEDURE AND CURRENTLY "BASELINE." THE PHYSICIAN PLANS TO BRING THE PATIENT TO SURGERY TO CLIP THE ANEURYSM; HOWEVER, NO DATE IS SET.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24743085 ↗
  • InjuryNov 9, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED THROUGH A RAGE CLINICAL STUDY, AN INTERVAL UNWINDING OF COIL MASS IN THE LUMEN OF THE ANEURYSMAL CAVITY WAS SUGGESTIVE OF PREVIOUS PRESENCE OF PARTIAL THROMBOSIS WITHIN THE ANEURYSM AT THE TIME OF EMERGENT END-VASCULAR REPAIR, AS WELL AS PRESENCE OF SMALL ANEURYSM NECK RECANALIZATION, SIZE 2.5X2.6X2.2. THE PATIENT UNDERWENT RETREATMENT WITH THE PLACEMENT OF A FLOW DIVERTER. THE PATIENT EXITED THE STUDY ON THE SAME DAY AS THE RETREATMENT. NO OTHER ADVERSE EVENTS ARE REPORTED.

    Patient problems: Aneurysm; Thrombosis/Thrombus

    MAUDE report 20646776 ↗
  • InjuryJun 4, 2021Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE PHYSICIAN WAS PERFORMING A BALLOON ASSISTED COILING PROCEDURE ON THE LEFT MIDDLE CEREBRAL ARTERY (MCA) AT THE BIFURCATION. WHILE ADVANCING THE COIL UP THE MICROCATHETER AND FIRST SEGMENT OF COIL WAS IN THE ANEURYSM, THE COIL UNEXPECTEDLY DETACHED IN THE MICROCATHETER WITHOUT ACTIVATING THE DETACHMENT CONTROLLER. A SNARE WAS USED AND SUCCESSFULLY RETRIEVED THE COIL. THERE WAS NO REPORT OF INJURY TO THE PATIENT, WHO WAS FINE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11942558 ↗
  • InjuryNov 7, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN UNEVENTFUL BALLOON ASSISTED COILING PROCEDURE FOR A RUPTURED RIGHT POSTERIOR COMMUNICATING ARTERY ANEURYSM WAS PERFORMED ON A PATIENT THAT PRESENTED WITH SUDDEN HEADACHE AND REDUCED CONSCIOUS LEVEL, AND SUBARACHNOID HEMORRHAGE. POST PROCEDURE, THE PATIENT WOKE UP WITH IPSILATERAL 3RD NERVE PALSY. THE CONDITION DID NOT IMPROVE WITH A SHORT COURSE OF STEROIDS, AND THE PATIENT UNDERWENT NEUROSURGICAL NERVE DECOMPRESSION TWO (2) DAYS LATER, WHICH WAS BELIEVED TO BE A RESULT OF AN IMMEDIATE MASS EFFECT OF THE COILED ANEURYSM ON THE 3RD NERVE.

    Patient problems: Neuropathy

    MAUDE report 8049356 ↗

Other Device, Vascular, for Promoting Embolization devices

All Device, Vascular, for Promoting Embolization devices →