HydroSoft 3D 7110-0206-3D-A2Recalls & reported problems

Microvention, Inc. · V-Trak · Class 2 · Implant

All models of HydroSoft 3D (26)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00816777025395), received between Aug 31, 2018 and Feb 9, 2026 — classified as 6 injuries, 1 malfunction.

The most frequently reported specific device problem is “Migration” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Migration3
  • Difficult or Delayed Positioning2
  • Premature Separation2
  • Component Missing1
  • Detachment of Device or Device Component1
  • Device-Device Incompatibility1
  • Difficult to Remove1
  • Stretched1

Patient problems

  • No Consequences Or Impact To Patient3
  • No Clinical Signs, Symptoms or Conditions2
  • Speech Disorder1
  • Thrombus1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 9, 2026Premature Separation

    IT WAS REPORTED THAT THE COIL BROKE WHILE BEING DEPLOYED THROUGH AN ATLAS STENT. ANOTHER STENT WAS NEEDED TO TACK THE COIL UP AND KEEP IT OUT OF THE PARENT VESSEL. NO INJURY TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24300304 ↗
  • InjurySep 28, 2024Component Missing; Migration; Component Missing; Migration

    ADDITIONAL INFORMATION WAS RECEIVED STATING THAT THE WARNING MARKERS WERE SEEN PRIOR TO THE COIL ENTERING THE PATIENT. WARNING MARKERS WERE NOT MISSING. THE COIL REMAINS IMPLANTED IN THE WRONG AREA. THE PATIENT WILL RECEIVE NO FURTHER TREATMENT. THE PATIENT'S CONDITION WAS REPORTED AS NOT HARMED. THE OPERATIVE REPORT WAS REQUESTED, BUT IT WAS NOT PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20329051 ↗
  • InjuryNov 3, 2023Migration; Premature Separation; Migration; Premature Separation

    A USER MEDWATCH WAS RECEIVED (B)(4) ON NOV 16TH, 2023, CONTAINING ADDITIONAL INFORMATION ABOUT THIS PREVIOUSLY REPORTED COMPLAINT. THE ADDITIONAL INFORMATION STATED THAT A 46 YR. OLD FEMALE PRESENTED FOR AN ELECTIVE CEREBRAL ANEURYSM COILING. THE STENTING OF THE VESSEL WAS SUCCESSFUL. THERE WAS NO EVIDENCE OF ACUTE OCCLUSION, AND THE PATIENT SYMPTOMS ARE IMPROVING.

    Patient problems: Speech Disorder

    MAUDE report 18066901 ↗
  • InjuryMay 16, 2019Difficult to Remove; Stretched; Detachment of Device or Device Component; Device-Device Incompatibility; Difficult to Remove; Stretched; Detachment of Device or Device Component; Device-Device Incompatibility

    A MEDSUN REPORT # (B)(4) WAS RECEIVED AND REPORTED THAT A PATIENT WITH A RIGHT MEDIAL TEMPORAL INTRA-CRANIAL HEMORRHAGE WITH ASSOCIATED RIGHT POSTERIOR COMMUNICATING ARTERY ANEURYSM UNDERWENT DIAGNOSTIC FEMORAL CEREBRAL ANGIOGRAM WITH PRIMARY COIL EMBOLIZATION OF THE RIGHT POSTERIOR COMMUNICATING ARTERY ANEURYSM. FOUR (4) COILS WERE DEPLOYED. FOLLOWING THIS, A HYRDROSOFT 3D (2MM X 6CM) COIL WAS DEPLYED. PER THE OPERATIVE REPORT, INCREASED RESISTANCE WAS MET UPON DEPLOYMENT OF THIS COIL, AND UPON RESPOSITIONING THE COIL WITHIN THE ANEURYSM SAC, THE COIL WAS IDENTIFIED TO HAVE STRETCHED AND DETACHED ON ITS OWN. IN THE PROCESS TO ADJUST, IT WAS NOTED THE COIL TAIL HERNIATED INTO THE INTERNAL CAROTID ARTERY. THE COIL WAS EVENTUALLY SNARED AND REMOVED. THERE WAS NO REPORTED PATIENT INJURY. THE EVENT DATE WAS NOTED AT (B)(6) 2019; HOWEVER, THE EXACT DATE WAS NOT PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8616696 ↗
  • InjuryFeb 7, 2019Difficult or Delayed Positioning; Difficult or Delayed Positioning

    IT WAS REPORTED THAT AFTER IMPLANTATION OF AN EMBOLIZATION COIL IN A PATIENT ENROLLED IN A CLINICAL TRIAL, A SMALL PORTION OF THE COIL (TAIL) EXTENDED INTO THE PARENT ARTERY. THE PATIENT WAS PRESCRIBED 325MG ASPIRIN DAILY. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8318969 ↗
  • InjurySep 11, 2018Difficult or Delayed Positioning; Difficult or Delayed Positioning

    IT WAS REPORTED THAT AFTER IMPLANTATION OF AN EMBOLIZATION COIL IN A RUPTURED INTERNAL CAROTID ARTERY ANEURYSM, THE PROXIMAL END OF THE COIL (TAIL) DID NOT STAY IN THE ANEURYSM AND EXTENDED INTO THE PARENT VESSEL. THERE WAS NO EVIDENCE OF THROMBUS FORMATION; HOWEVER, THE PATIENT HAS BEEN PRESCRIBED DAILY BABY ASPIRIN TO AVOID PLATELET AGGREGATION. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7866304 ↗
  • InjuryAug 31, 2018Migration; Migration

    IT WAS REPORTED THAT AN EMBOLIZATION COIL WAS IMPLANTED IN A RUPTURED BASILAR APEX ANEURYSM ON (B)(6) 2018. APPROXIMATELY 13 DAYS LATER, A STRAIGHT, TAIL-LIKE SEGMENT OF THE COIL CAME OUT OF THE ANEURYSM INTO THE PROXIMAL RIGHT POSTERIOR CEREBRAL ARTERY. A CLOT WAS NOTED AROUND THE TAIL SEGMENT, AND A THALAMIC STROKE WAS OBSERVED. ASPIRIN AND HEPARIN WERE ADMINISTERED TO THE PATIENT AS TREATMENT FOR THE CLOT. A CEREBRAL ANGIOGRAPHY SHOWED NO EVIDENCE OF THROMBOEMBOLIC COMPLICATIONS. THE CLOT APPEARS TO HAVE RESOLVED AND THERE ARE NO STROKE SYMPTOMS. THE PATIENT IS REPORTED TO BE RECOVERING WELL.

    Patient problems: Thrombus

    MAUDE report 7840080 ↗

Other Device, Vascular, for Promoting Embolization devices

All Device, Vascular, for Promoting Embolization devices →