HydroSoft 3D 7110-0256-3D-A2Recalls & reported problems

Microvention, Inc. · V-Trak · Class 2 · Implant

All models of HydroSoft 3D (26)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00816777025432), received between Sep 12, 2018 and Nov 7, 2024 — classified as 5 injuries, 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component4
  • Adverse Event Without Identified Device or Use Problem1
  • Device Dislodged or Dislocated1
  • Difficult to Remove1

Patient problems

  • No Consequences Or Impact To Patient5
  • Aneurysm expansion1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 7, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    NO ADDITIONAL INFORMATION WAS PROVIDED, PLEASE SEE H6 & H11.

    Patient problems: Aneurysm expansion

    MAUDE report 20631233 ↗
  • InjuryJul 17, 2020Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING PLACEMENT OF AN EMBOLIZATION COIL IN AN ANEURYSM, THE COIL UNEXPECTEDLY DETACHED IN THE VESSEL. THE DETACHED COIL SEGMENT WAS RETRIEVED FROM THE PATIENT WITH A COMANECI DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10292688 ↗
  • InjuryJun 19, 2020Difficult to Remove; Detachment of Device or Device Component; Difficult to Remove; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING TREATMENT OF AN ACOM ANEURYSM, THE EMBOLIZATION COIL WAS REPOSITIONED TWICE. DURING THE 3RD ATTEMPT TO WITHDRAW THE COIL, THE COIL STRETCHED AND THEN DETACHED, LEAVING A 5-6CM REMNANT IN A PORTION OF THE A1 SEGMENT AND THE PARENT INTERNAL CAROTID ARTERY. AFTER AN EXCHANGE OF MICROCATHETERS, A STENTRIEVER WAS USED TO CAPTURE THE ENTIRE DETACHED COIL SEGMENT FROM THE PATIENT. THE ANEURYSM WAS SUCCESSFULLY TREATED WITH SUBSEQUENT COILS. THERE WAS NO REPORTED PATIENT INJURY. THE PATIENT IS CURRENTLY REPORTED TO BE STABLE AND DOING WELL POST-PROCEDURE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10176114 ↗
  • MalfunctionJun 9, 2020Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING PLACEMENT OF AN EMBOLIZATION COIL INTO A SMALL ANEURYSM, THE MICROCATHETER SLIPPED INTO THE PARENT ARTERY. THE MICROCATHETER WAS TRACKED OVER THE COIL TO RE-ACCESS THE ANEURYSM. WHILE TRYING TO ADVANCE THE LAST LOOP IN THE ANEURYSM, THE COIL DETACHED IN THE MICROCATHETER. THE COIL WAS PUSHED INTO THE ANEURYSM WITH 50/50 CONTRAST/SALINE USING A 3ML SYRINGE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10131627 ↗
  • InjuryJun 5, 2019Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING EMBOLIZATION OF A PCOM ANEURYSM, THE COIL WAS BEING USED AS A GUIDEWIRE TO GAIN ACCESS TO THE ANEURYSM. DURING THIS MANIPULATION, THE COIL DETACHED AND OVER HALF OF THE COIL WAS IN THE PARENT VESSEL. THE COIL WAS RETRIEVED WITH A STENTRIEVER AND AN ASPIRATION CATHETER. THERE WAS NO REPORTED SYMPTOMS OR INJURIES RELATED TO THE COILING OR RETRIEVAL OF THE COIL.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8672190 ↗
  • InjurySep 12, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT A BALLOON-ASSISTED COILING PROCEDURE WAS PERFORMED ON A PATIENT WITH A RECURRENT BASILAR TIP SACCULAR ANEURYSM. AFTER DELIVERY OF A BALLOON CATHETER INTO THE POSTERIOR CEREBRAL ARTERY, TWO COILS WERE SUCCESSFULLY PLACED IN THE ANEURYSM. SUBSEQUENTLY, A COIL LOOP WAS NOTED TO PROJECT AT THE BASILAR BIFURCATION, MORE TOWARDS THE ORIGIN OF THE RIGHT P1 ARTERY. THE BALLOON WAS INFLATED MULTIPLE TIMES, WHICH REPOSITIONED THE COIL MASS AND CENTRALIZED THE COIL LOOP AT THE BASILAR BIFURCATION. BOTH POSTERIOR CEREBRAL ARTERIES WERE PATENT. THE DECISION WAS MADE TO STOP TREATMENT AT THAT POINT AND MAINTAIN THE PATIENT ON DUAL ANTIPLATELET THERAPY FOR 3 MONTHS. THE PATIENT AWOKE FROM GENERAL ANESTHESIA NEUROLOGICALLY INTACT AND WAS REPORTED TO BE STABLE WITH NO NEW NEUROLOGICAL DEFICITS UPON HOSPITAL DISCHARGE. THE PATIENT IS ENROLLED IN A POST-MARKET CLINICAL TRIAL AND IS BEING MONITORED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7871434 ↗

Other Device, Vascular, for Promoting Embolization devices

All Device, Vascular, for Promoting Embolization devices →