HydroSoft 3D 100206HFRM-V-3D-A2Recalls & reported problems

Microvention, Inc. · V-Trak · Class 2 · Implant

All models of HydroSoft 3D (26)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00816777026514), received between Feb 6, 2020 and Dec 27, 2024 — classified as 2 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 2 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component2
  • Device-Device Incompatibility2
  • Adverse Event Without Identified Device or Use Problem1
  • Material Separation1
  • Premature Separation1
  • Stretched1
  • Unraveled Material1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Consequences Or Impact To Patient2
  • Muscle Weakness/Atrophy1
  • Ruptured Aneurysm1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 27, 2024Material Separation; Stretched; Premature Separation; Material Separation; Stretched; Premature Separation

    AS REPORTED: MCA ANEURYSM TREATMENT, USUAL COIL USAGE STARTED. DURING PREPARATION OF COIL, THEY REALISED SOME WIRE DEBRIS ON THE HYPOTUBE. STARTED THE ACCESS INTO THE MICROCATHETER AND THE DEVICE WAS DETACHED FROM THE PUSHER. REMOVED ALL PARTS AND COLLECTED. PATIENT TREATED WITH OTHER COILS SUCCESSFULLY. PATIENT IS IN GOOD CONDITION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21028320 ↗
  • InjuryDec 6, 2024Unraveled Material; Unraveled Material

    SEE H10.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20860704 ↗
  • InjuryMar 18, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PROCEDURE WAS FOR TREATMENT OF AN ACUTELY RUPTURED A2 SEGMENT ANEURYSM. THE EMBOLIZATION COIL WAS BEING USED AS THE SECOND COIL WHEN IT UNINTENTIONALLY DETACHED FROM THE PUSHER WIRE. A BALLOON WAS THEN INTRODUCED AND INFLATED TO PREVENT COIL PROLAPSING INTO PARENT VESSEL AND THE DESCRIBED COIL WAS PUSHED INTO THE ANEURYSM. ONCE THE COIL WAS SUCCESSFULLY PLACED WITHIN THE ANEURYSM, THE OPERATOR PULLED THE PUSHER WIRE BACK BUT THE PROXIMAL END OF THE COIL ALSO PULLED BACK. THE DETACHMENT CONTROLLER WAS THEN ATTACHED AND THE COIL WAS DETACHED SUCCESSFULLY. A SMALL AMOUNT OF EXTRAVASATION/RUPTURE OF THE ANEURYSM WAS NOTED, WHICH WAS QUICKLY TREATED WITH FURTHER COILS BEING PLACED. PATIENT INITIALLY HAD RIGHT SIDED WEAKNESS IN UPPER AND LOWER LIMB AND REPORTEDLY REGAINED LIMB POWER OVER FOLLOWING DAYS.

    Patient problems: Muscle Weakness/Atrophy; Ruptured Aneurysm

    MAUDE report 13805520 ↗
  • MalfunctionMar 19, 2020Detachment of Device or Device Component; Device-Device Incompatibility; Detachment of Device or Device Component; Device-Device Incompatibility

    IT WAS REPORTED THAT BALLOON-ASSISTED COILING WAS PERFORMED FOR AN MIDDLE CEREBRAL ARTERY (MCA) BIFURCATION ANEURYSM. DURING PLACEMENT OF THE THIRD COIL, RESISTANCE WAS ENCOUNTERED AND DURING THE ATTEMPT TO REMOVE THE COIL, IT DETACHED IN THE MICROCATHETER. BOTH SEGMENTS OF THE COIL WERE REMOVED TOGETHER WITH THE MICROCATHETER. THERE WAS NO REPORTED PATIENT INJURY OR ADDITIONAL INTERVENTION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9857954 ↗
  • MalfunctionFeb 6, 2020Detachment of Device or Device Component; Device-Device Incompatibility; Detachment of Device or Device Component; Device-Device Incompatibility

    IT WAS REPORTED THAT COIL EMBOLIZATION WAS PERFORMED FOR AN INTERNAL CAROTID ARTERY ANEURYSM. WHILE ADVANCING THE THIRD COIL, RESISTANCE WAS ENCOUNTERED AND DURING WITHDRAWAL, THE COIL DETACHED INSIDE THE MICROCATHETER. BOTH SEGMENTS OF THE COIL WERE REMOVED IN THEIR ENTIRETY TOGETHER WITH THE MICROCATHETER. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9679408 ↗

Other Device, Vascular, for Promoting Embolization devices

All Device, Vascular, for Promoting Embolization devices →