Skip to content

VSP System Surgical SplintRecalls & reported problems

3d Systems, Inc. · A physical template / guide that conforms to patients’ anatomy (Bony and / or Occlusal) to allow manipulation of free floating bony anatomy. · Class 2

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00816847020510), received between Jan 12, 2022 and Jun 18, 2025 — classified as 2 injuries.

The most frequently reported specific device problem is “Compatibility Problem” (1 report).

1 other recall cover devices cleared under the same FDA submission (K120956, K133907, K192192); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Compatibility Problem1
  • Device-Device Incompatibility1
  • Patient-Device Incompatibility1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 18, 2025Patient-Device Incompatibility; Patient-Device Incompatibility

    A MAXILLOFACIAL SURGICAL PROCEDURE UTILIZING VSP SYSTEMS PRODUCTS WAS CANCELED DUE TO A REPORTED SURGICAL SPLINT FIT CONCERN AFTER INCISIONS WERE MADE, PREVENTING THE SURGEON FROM PROCEEDING WITH OSTEOTOMIES. DIGITAL REVIEWS WERE UNABLE TO REPLICATE THE REPORTED FIT ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22288138 ↗
  • InjuryJan 12, 2022Device-Device Incompatibility; Compatibility Problem; Device-Device Incompatibility; Compatibility Problem

    FOR A VSP ORTHOGNATHIC PROCEDURE, THE SURGEON WAS NOT ABLE ACHIEVE A FLUSH FIT AT THE CONNECTING POINT BETWEEN TWO HYBRID VSP 2.0 GUIDES (NYLON INITIAL SURGICAL SPLINT AND TITANIUM RIGHT MAXILLA CUTTING GUIDE). AS A RESULT, THE SURGEON HAD TO REPLATE THE PATIENT'S MAXILLA.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13236689 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K120956, K133907, K192192. One submission often covers many models, so check the product and lot details in each record.

  • Z-1510-2022 · May 17, 2022 · Open, Classified
    3D Systems VSP Reconstruction, Model: VSPR-301 Product: Scapula Marking Guide (Anatomically Shaped), Rx Only, Non-Sterile

Other System, Image Processing, Radiological devices

All System, Image Processing, Radiological devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.