VSP System Fibula Cutting Guide with Implant PlacementRecalls & reported problems

3d Systems, Inc. · A physical template / guide that is positioned on patients’ anatomy (Bony and / or Occulsal), and allows for precise location of predetermined osteotomy planes and holes. · Class 2

All models of VSP System (14)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00816847020770), received between Nov 7, 2019 and Dec 16, 2025 — classified as 6 injuries.

The most frequently reported specific device problem is “Inaccurate Information” (2 reports).

1 other recall cover devices cleared under the same FDA submission (K120956, K133907, K192192); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Inaccurate Information2
  • Patient-Device Incompatibility2
  • Adverse Event Without Identified Device or Use Problem1
  • Device Markings/Labelling Problem1
  • Labelling, Instructions for Use or Training Problem1
  • Patient Device Interaction Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • No Code Available2

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 16, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A 30-45 MINUTE DELAY WAS CAUSED FROM BURRING THE FIBULA SEGMENTS TO FIT THE PLATE. THE SURGEON INDICATED HE SHIFTED THE GUIDE ON THE FIBULA. THE GUIDE REGISTERED WELL BUT LIKELY IN A DIFFERENT ROTATION. THE PATIENT WILL REQUIRE A REVISION SURGERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23823207 ↗
  • InjurySep 21, 2023Patient Device Interaction Problem; Patient Device Interaction Problem

    DURING THE PROCESS OF A MANDIBLE RECONSTRUCTIVE SURGERY, A FIBULA CUTTING GUIDE WAS UTILIZED WHICH RESULTED IN DENTAL IMPLANT HOLES THAT DID NOT PROPERLY ALIGN TO THE PLANNED SURGICAL POSITIONS. AS A RESULT, THE DENTAL IMPLANT HOLES WERE NOT USED AND A REVISION SURGERY WAS SCHEDULED TO CORRECT THE PLACEMENT OF THE DENTAL IMPLANT HOLES. A REVIEW OF THE GUIDE FOUND THAT ALL REQUIREMENTS WERE MET AND NO DEFECTS WERE FOUND IN THE DESIGN OR MANUFACTURING OF THE GUIDE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17790071 ↗
  • InjuryFeb 1, 2022Device Markings/Labelling Problem; Inaccurate Information; Device Markings/Labelling Problem; Inaccurate Information

    DURING A VSP RECONSTRUCTION PROCEDURE, IT WAS IDENTIFIED THAT THE FIBULA GUIDE WAS LABELED INCORRECTLY. THE GUIDE WAS LABELLED LEFT FIBULA TO RIGHT NECK; AND THE CORRECT SURGICAL PROCEDURE WAS LEFT FIBULA TO LEFT NECK.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13417656 ↗
  • InjuryNov 21, 2021Labelling, Instructions for Use or Training Problem; Inaccurate Information; Labelling, Instructions for Use or Training Problem; Inaccurate Information

    FOR A VSP RECONSTRUCTION PROCEDURE, THE SURGEON IDENTIFIED AN ERROR DOCUMENTED IN THE 3D SYSTEMS CASE REPORT. THE PLAN B VSP RECONSTRUCTION SURGICAL PLAN DOCUMENTED THE PLAN A FIBULA GUIDE IN ONE OF THE IMAGES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12849857 ↗
  • InjuryJul 17, 2020Patient-Device Incompatibility; Patient-Device Incompatibility

    THE DENTAL IMPLANT PLACEMENT ON THE FIBULA CUTTING GUIDE WITH IMPLANT PLACEMENT WAS PLACED ON THE ANTERIOR SURFACE INSTEAD OF THE POSTERIOR SURFACE. THE ISSUE WAS IDENTIFIED PRIOR TO SURGERY AND THE IMPLANT PLACEMENT FEATURE ON THE GUIDE WAS NOT USED. THE ISSUE CAUSED NO HARM TO THE PATIENT AND DID NOT CAUSE A DELAY IN SURGERY.

    Patient problems: No Code Available

    MAUDE report 10292304 ↗
  • InjuryNov 7, 2019Patient-Device Incompatibility; Patient-Device Incompatibility

    THE DENTAL IMPLANT PLACEMENT ON THE FIBULA CUTTING GUIDE WITH IMPLANT PLACEMENT WAS PLACED ON THE ANTERIOR SURFACE INSTEAD OF THE POSTERIOR SURFACE.

    Patient problems: No Code Available

    MAUDE report 9293209 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K120956, K133907, K192192. One submission often covers many models, so check the product and lot details in each record.

  • Z-1510-2022 · May 17, 2022 · Open, Classified
    3D Systems VSP Reconstruction, Model: VSPR-301 Product: Scapula Marking Guide (Anatomically Shaped), Rx Only, Non-Sterile

Other Driver, Wire, And Bone Drill, Manual devices

All Driver, Wire, And Bone Drill, Manual devices →