VSP System Mandible Marking GuideRecalls & reported problems

3d Systems, Inc. · A physical template / guide that is positioned on patients’ anatomy (Bony and / or Occulsal), and allows for precise location of predetermined osteotomy planes and holes. · Class 2

Adverse event reports
7
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00816847020824), received between Jun 30, 2022 and Mar 17, 2026 — classified as 6 injuries, 1 malfunction.

The most frequently reported specific device problem is “Malposition of Device” (2 reports).

1 other recall cover devices cleared under the same FDA submission (K120956, K133907, K192192); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 1 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem5
  • Malposition of Device2

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Failure of Implant2
  • Nerve Damage1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 17, 2026Adverse Event Without Identified Device or Use Problem

    WHILE PERFORMING THE VERTICAL OSTEOTOMY OF THE BSSO, THE RESIDENT ASSUMED THE CUTTING SLOT ENDED AT THE INFERIOR BORDER AND CONTINUED CUTTING BASED OFF THAT. CONFUSION ALSO AROSE WHEN LOOKING AT THE NERVE TO DISTAL MANDIBLE MEASUREMENTS IN THE CASE REPORT AS THE RESIDENT BELIEVED THERE SHOULD'VE BEEN TWO MEASUREMENTS - ONE AT THE ANTERIOR CUT OF THE WEDGE AND ANOTHER AT THE POSTERIOR. THESE COMBINED RESULTED IN THE PATIENTS NERVES BEING SEVERED BILATERALLY.

    Patient problems: Nerve Damage

    MAUDE report 24617726 ↗
  • InjuryFeb 6, 2026Adverse Event Without Identified Device or Use Problem

    SURGEON REPORTED DIFFICULTIES DURING A MAXILLOFACIAL PROCEDURE INVOLVING VSP SYSTEM DEVICES. SURGICAL COMPLICATIONS RELATED TO THE FIT OF THE CUSTOM PLATES RESULTED IN THE SCHEDULING OF A REVISION SURGERY TO ADDRESS CONCERNS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24279956 ↗
  • MalfunctionJun 18, 2024Malposition of Device; Malposition of Device

    FOLLOWING A MAXILLOFACIAL PROCEDURE UTILIZING VSP SYSTEMS PRODUCTS, IT WAS REPORTED THAT THE SURGEON WAS UNHAPPY WITH THE SURGICAL OUTCOME AND INTENDS TO PERFORM A REVISION SURGERY. IN PARTICULAR, THE SURGEON NOTED DIFFICULTY UTILIZING THE PROVIDED MANDIBLE CUTTING GUIDES.

    Patient problems: Failure of Implant

    MAUDE report 19559935 ↗
  • InjuryMay 23, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FOLLOWING A MAXILLOFACIAL PROCEDURE UTILIZING VSP SYSTEMS PRODUCTS, IT WAS REPORTED THAT THE SURGEON HAD OPERATIVE DIFFICULTIES UTILIZING THE PROVIDED 3D SYSTEMS MANDIBLE MARKING GUIDE AND SUBSEQUENT DIFFICULTIES IN THE PLACEMENT OF THE MANDIBLE PROSTHESIS. THIS RESULTED IN AN OPERATIVE DELAY OF MORE THAN TWO HOURS AND IT HAS BEEN REPORTED THAT A REVISION SURGERY IS BEING PLANNED.

    Patient problems: Failure of Implant

    MAUDE report 19383290 ↗
  • InjuryApr 24, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    FOLLOWING A MAXILLOFACIAL SURGERY, IT WAS REPORTED THAT THE SURGEON HAD DIFFICULTY FITTING A MANDIBLE PROSTHESIS TO THE PATIENT USING A 3D SYSTEMS MANDIBLE MARKING GUIDE, WHICH CAUSED A DELAY IN THE OPERATION OF APPROXIMATELY 4 HOURS. THE PROCEDURE WAS COMPLETED WITHOUT ADDITIONAL PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19175138 ↗
  • InjuryNov 15, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DURING A CONDYLECTOMY PROCEDURE, A SURGEON REPORTED DISCOVERING A MISALIGNMENT BETWEEN THE PREDICTED SCREW HOLE LOCATIONS OF A 3D SYSTEM'S DEVICE AND THE PATIENT'S ANATOMY. ADDITIONAL HOLES WERE DRILLED IN THE PATIENT'S MANDIBLE TO ENSURE PROPER IMPLANT PLACEMENT. POST-PROCEDURE INVESTIGATION REVEALED NO IDENTIFIABLE PRODUCT OR PROCESS DEFICIENCIES THAT WOULD ACCOUNT FOR THIS MIS-ALIGNMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18141891 ↗
  • InjuryJun 30, 2022Malposition of Device; Malposition of Device

    DURING A VSP ORTHOGNATHICS AND TMJ SURGERY, THERE WERE ISSUES WITH THE FIT OF THE MANDIBULAR PROSTHESIS. THE SURGEON DRILLED THE PREDICTIVE HOLES INDICATED BY THE MANDIBLE MARKING GUIDE AND LATER FOUND THAT THE MANDIBULAR PROSTHESIS WOULD NOT MEET THE FOSSA ONCE IT WAS SCREWED INTO THE MANDIBLE. AS A RESULT, THE SURGEON DID NOT USE THE PRE-DRILLED HOLES AND PREFERRED A DIFFERENT POSITIONING OF THE MANDIBLE PROSTHESIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14881088 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K120956, K133907, K192192. One submission often covers many models, so check the product and lot details in each record.

  • Z-1510-2022 · May 17, 2022 · Open, Classified
    3D Systems VSP Reconstruction, Model: VSPR-301 Product: Scapula Marking Guide (Anatomically Shaped), Rx Only, Non-Sterile

Other System, Image Processing, Radiological devices

All System, Image Processing, Radiological devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.