VSP Orthopedics Allograft Tibia Cutting GuideRecalls & reported problems
3d Systems, Inc. · A physical guide that is composed of allograft bony anatomy and allows for precise location of predetermined osteotomy planes and holes. · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00816847021845), received between Sep 10, 2020 and Sep 10, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Patient-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Patient-Device Incompatibility1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 10, 2020Patient-Device Incompatibility; Patient-Device Incompatibility
FOR A VSP ORTHOPEDICS TIBIA RESECTION AND ALLOGRAFT RECONSTRUCTION PROCEDURE, THE SURGEON NOTED THE FOLLOWING ISSUES: THE ALLOGRAFT TIBIA CUTTING GUIDE DID NOT FIT THE ALLOGRAFT. THE PATIENT'S NATIVE REMAINING BONY ANATOMY AT THE PROXIMAL END OF THE TIBIA FRACTURED DURING THE CUTTING PROCESS USING THE PATIENT TIBIA CUTTING GUIDE. INVESTIGATION AT THIS TIME REVEALED NO ROOT CAUSE ATTRIBUTED TO 3D SYSTEMS FOR THE ABOVE ISSUES. NO ADDITIONAL SURGICAL INTERVENTION WAS REQUIRED. AN INCORRECT REVISION OF THE CASE REPORT WAS PROVIDED TO THE SURGEON. THIS WAS IDENTIFIED AND CORRECTED PRIOR TO SURGERY.
Patient problems: Bone Fracture(s)
MAUDE report 10518178 ↗
FDA clearance and classification
Cleared through 510(k) K190044 on Aug 21, 2019 (decision: Substantially Equivalent). Submitted by 3D Systems, Inc. as “VSP Orthopedics System”. The FDA review took 224 days. FDA record ↗
The FDA regulates product code PBF (orthopaedic surgical planning and instrument guides) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
FDA definition of this device type: As a surgical instrument to assist in pre-operative planning and/or guiding the marking of bone and/or guide surgical instruments for orthopedic surgical procedures.
Common questions about the VSP Orthopedics Allograft Tibia Cutting Guide
Has the VSP Orthopedics Allograft Tibia Cutting Guide been recalled?
No FDA recall record in our data names this exact device identifier (DI 00816847021845), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the VSP Orthopedics Allograft Tibia Cutting Guide?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 10, 2020. That report lists device problem “Patient-Device Incompatibility” (1); patient problem “Bone Fracture(s)” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the VSP Orthopedics Allograft Tibia Cutting Guide?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the VSP Orthopedics Allograft Tibia Cutting Guide FDA approved?
It was cleared through 510(k) K190044 on Aug 21, 2019. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the VSP Orthopedics Allograft Tibia Cutting Guide MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Unsafe: it should not be taken into an MRI scanner room.
Who makes the VSP Orthopedics Allograft Tibia Cutting Guide, and is it still sold?
The FDA's device database lists 3d Systems, Inc. as the company responsible for it (brand VSP Orthopedics, model Allograft Tibia Cutting Guide). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Orthopaedic Surgical Planning And Instrument Guides devices
- Trabecular Metal 20-8075-004-01Orthosoft Inc · Orthopaedic Surgical Planning And Instrument Guides2 reports
- CORIOGRAPH ROB20030Smith & Nephew, Inc. · Orthopaedic surgical planning and instrument guides2 reports
- SurgiCase UEA-MA01-00-01Materialise NV · Orthopaedic Surgical Planning And Instrument Guides2 reports
- SurgiCase O-01-0-101000-0011-010Materialise NV · Orthopaedic Surgical Planning And Instrument Guides1 report
- SurgiCase O-01-0-105000-0011-010Materialise NV · Orthopaedic Surgical Planning And Instrument Guides1 report
- Materialise Personalized Solutions O-01-0-101000-0011-010Materialise NV · Orthopaedic Surgical Planning And Instrument Guides1 report
- VSP Orthopedics Allograft Orthopedic Model3d Systems, Inc. · Orthopaedic Surgical Planning And Instrument Guides1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page