Hydra SIT-361Recalls & reported problems
Boston Scientific Corporation · Disposable Auxiliary Water Jet Connector Compatible with Olympus scopes · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00816849017525), received between Dec 20, 2019 and Jul 24, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Defective Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Defective Device1
- Leak/Splash1
- Reflux within Device1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 24, 2025Leak/Splash; Reflux within Device; Use of Device Problem; Leak/Splash; Reflux within Device; Use of Device Problem
IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A HYDRA OLYMPUS WATER JET CONNECTOR WAS USED IN THE ESOPHAGUS DURING A GASTROSCOPY PROCEDURE PERFORMED FOR THE TREATMENT OF ESOPHAGEAL VARICES ON (B)(6) 2025. DURING THE PROCEDURE WHILE LIGATING THE ESOPHAGEAL VARICES, A LEAK WAS NOTICED ACROSS THE ENDOSCOPE LENS WHILE APPLYING SUCTION. AT THE END OF THE PROCEDURE, IT WAS FOUND OUT THAT THE CONTAMINATED FLUID HAD RUN THROUGH THE HYDRA OLYMPUS WATER JET CONNECTOR AND ENTERED THE JET WASHER TUBING. THE PROCEDURE WAS COMPLETED WITH THIS DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE "FULLY RECOVERED".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22586342 ↗MalfunctionDec 20, 2019Defective Device; Defective Device
NOTE: THIS REPORT PERTAINS TO TWO OF TWO DEVICES USED IN THE SAME PROCEDURE. IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT HYDRA IRRIGATION TUBING AND A WATER JET CONNECTOR WAS USED IN A COLONOSCOPY PROCEDURE PERFORMED ON (B)(6)2019. ACCORDING TO THE COMPLAINANT, WHILE HYDRA IRRIGATION TUBING WAS CONNECTED TO A HYDRA WATER JET CONNECTOR, BACKFLOW OF LIQUID WAS OBSERVED. THE PROCEDURE WAS COMPLETED USING ANOTHER HYDRA IRRIGATION TUBING AND WATER JET CONNECTOR. THERE WAS NO SERIOUS INJURY NOR ADVERSE PATIENT EFFECTS REPORTED AS A RESULT OF THIS EVENT AND THE PATIENT WAS REPORTED TO BE STABLE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9506137 ↗
Other PUMP, AIR, NON-MANUAL, FOR ENDOSCOPE devices
- OLYMPUS OFP-2 (ROW)Keymed (Medical & Industrial Equipment) Limited · Pump, Air, Non-Manual, For Endoscope296 reports
- Olympus MAJ-1651Keymed (Medical & Industrial Equipment) Limited · Pump, Air, Non-Manual, For Endoscope125 reports
- Olympus WB991046OLYMPUS Winter & Ibe GmbH · Pump, Air, Non-Manual, For Endoscope81 reports
- ERBEFLO CleverCap® 20325-239Erbe Medical, LLC · Pump, Air, Non-Manual, For Endoscope1 recall24 reports
- OLYMPUS OFP-2 (US)Keymed (Medical & Industrial Equipment) Limited · Pump, Air, Non-Manual, For Endoscope1 recall22 reports
- ERBEFLO CleverCap® 20325-206Erbe Medical, LLC · Pump, Air, Non-Manual, For Endoscope1 recall5 reports
- ERBEFLO CleverCap® 20325-248Erbe Medical, LLC · Pump, Air, Non-Manual, For Endoscope1 recall3 reports
- ERBEFLO CleverCap® 20325-240Erbe Medical, LLC · Pump, Air, Non-Manual, For Endoscope1 recall3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page