Skip to content

Optima Coil System OPTI2525CSSMXRecalls & reported problems

Balt USA LLC · The Optima Coil System is indicated for endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations (AVMs) and arteriovenous fistulae. The Optima Coil System is also indicated for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolization in the peripheral vasculature. The Optima Coil System comprises of implant coil and a pusher assembly. The Optima Coil System is designed fr use with the XCEL Detachment Controller. The Optima coil is detached thermally with the XCEL Detachment Controller. · Class 2 · Implant

All models of Optima Coil System (379)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
2
Deaths reported
1
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00818053025013), received between Aug 20, 2020 and Sep 16, 2020 — classified as 1 death, 1 malfunction.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

4 other recalls cover devices cleared under the same FDA submission (K200030); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Jan 3, 2024Class IIOpen, Classified

    Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the hypotube component of the delivery pusher. Due to the location of the delivery pusher within the delivery system, it is possible for the discoloration to mechanically break off from the delivery pusher, leaving the potential for the material to flow through the delivery system (i.e. microcatheter), and into the patient vasculature causing foreign emboli.

    Z-1041-2024 · Root cause: Material/Component Contamination · Recall details · FDA record ↗

Most reported problems

Device problems

  • Device Dislodged or Dislocated1
  • Migration1
  • Positioning Failure1

Patient problems

  • Aneurysm2
  • Death1
  • Pulmonary Emphysema1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 16, 2020Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED: "AFTER FRAMING WITH THE 2.5X2.5 OPTIMAX THE PHYSICIAN DETACHED THE COIL AND OPENED A 1X1 OPTIMAX BUT WHEN HE WENT TO PLACE THE COIL HE NOTICED HIS MICROCATHETER HAD COME BACK. HE PULLED THE COIL OUT USED THE HYBRID 1214 TO ACCESS THE ANEURYSM BUT WHEN HE INSERTED THE SL-10 OVER THE WIRE INTO THE ANEURYSM IT DISLODGED THE 2.5Z2.5 OPTIMAX. THE PHYSICIAN DROPPED AN ATLAS STENT THROUGH THE COIL AND ACROSS THE NECK OF THE ANEURYSM AND THEN CROSSED THE STENT AND PLACED 5 OPTIMA COILS TO FINISH THE PROCEDURE. I HAVE INCLUDED IMAGES OF THE INITIAL FRAME, STENTED 2.5X2.5 AND THE FINAL RESULT."

    Patient problems: Aneurysm

    MAUDE report 10543953 ↗
  • DeathAug 20, 2020Positioning Failure; Migration; Positioning Failure; Migration

    IT WAS REPORTED THROUGH AN AUTOMATED REPORTING SYSTEM FROM ACTIVE CLINICAL STUDY: "A SERIOUS ADVERSE EVENT WAS ADDED: SITE ID: #105. PATIENT ID: (B)(6). YEAR OF BIRTH: 1954. ADVERSE EVENT FORM NUMBER: #3. EVENT DESCRIPTION: PATIENT DECEASED. DATE OF EVENT ONSET: (B)(6) 2020. SERIOUSNESS: LED TO A DEATH. RELATIONSHIP TO OPTIMA COILS SYSTEM: RELATIONSHIP TO PROCEDURE: RELATIONSHIP TO A BALT DEVICE: IF YES, SPECIFY DEVICE: IF YES, SPECIFY RELATIONSHIP: OTHER RELATIONSHIP: IF YES, SPECIFY: ACTION: EVENT STATUS: DEATH. DATE OF EVENT RESOLUTION OR DEATH: (B)(6) 2020. CREATED BY: (B)(6). DATE OF CREATION: 7/3/20 1:23 PM. FOLLOW UP PROVIDED (07/17/2020): 'THE DEATH OCCURRED SEVERAL MONTHS AFTER THE PROCEDURE WITH OPTIMA COILS IN ANOTHER HOSPITAL NOT INVOLVED IN THE INSTANT STUDY THAT IS WHY WE HAVE DIFFICULTIES TO COLLECT THE RELATIONSHIP TO THE STUDY DEVICE. THE HOSPITAL WHERE THE DEATH OCCURRED INFORM US THAT THE REPORT WILL BE AVAILABLE AFTER 10TH OF AUGUST ( DUE TO HOLIDAYS )AND NOT BEFORE. THE INSTANT STUDY SITE STAFF WHERE THE PATIENT WAS ENROLLED ( FRENCH SITE IN BORDEAUX) DOESN'T THINK THAT THE EVENT IS LINKED TO THE OPTIMA BUT TO BE SURE WE NEED TO WAIT FOR THE DEATH REPORT (FROM

    Patient problems: Aneurysm; Death; Pulmonary Emphysema

    MAUDE report 10431348 ↗

FDA clearance and classification

Cleared through Special 510(k) K200030 on Feb 1, 2020 (decision: Substantially Equivalent). Submitted by Balt USA, LLC as “Optima Coil System”. The FDA review took 25 days. FDA record ↗

The FDA regulates product code KRD (device, vascular, for promoting embolization) under 21 CFR 870.3300 as a Class II device. 21 CFR 870.3300 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K200030. One submission often covers many models, so check the product and lot details in each record.

  • Z-1988-2025 · May 8, 2025 · Open, Classified
    Optima Coil System REFs/UDI-DI codes: OPTI0156BLK 00810068568875 OPTI0158BLK 00810068568882 OPTI0103BLK 00810068568851 OPTI0258BLK 00810068568929 OPTI0212BLK 00810068568912 OPTI020
  • Z-0103-2023 · Sep 7, 2022 · Open, Classified
    Optima Coil System Model Number OPTI0208CSS10, Model Number OPTI0308CSS10. Used in endovascular procedures.
  • Z-1680-2022 · Jul 26, 2022 · Open, Classified
    Optima Coil System Model OPTI0520CSF10. For endovascular embolization.
  • Z-0660-2022 · Jan 4, 2022 · Open, Classified
    The Optima Coil System consists of an implantable embolization coil comprised of a platinum-tungsten alloy attached to a proximal stainless steel hypo-tube and distal body coil del

Common questions about the Optima Coil System OPTI2525CSSMX

Has the Optima Coil System OPTI2525CSSMX been recalled?

Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1041-2024 (Class II), began on Jan 3, 2024: Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the Optima Coil System OPTI2525CSSMX?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Aug 20, 2020 and Sep 16, 2020. In those reports, the most common specific device problems are “Device Dislodged or Dislocated” (1), “Migration” (1) and “Positioning Failure” (1); the most common patient problems are “Aneurysm” (2), “Death” (1) and “Pulmonary Emphysema” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Optima Coil System OPTI2525CSSMX?

1 report is classified as a death, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Optima Coil System OPTI2525CSSMX FDA approved?

It was cleared through Special 510(k) K200030 on Feb 1, 2020. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the Optima Coil System OPTI2525CSSMX MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the Optima Coil System OPTI2525CSSMX, and is it still sold?

The FDA's device database lists Balt USA LLC as the company responsible for it (brand Optima Coil System, model OPTI2525CSSMX). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Device, Vascular, For Promoting Embolization devices

All Device, Vascular, For Promoting Embolization devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page