Optima Coil System OPTI0308CSS10 (REF N/A)Recalls & reported problems
Balt USA LLC · The Optima Coil System is indicated for endovascular embolization of intracranial aneurysms and other neurovascular abnormalities such as arteriovenous malformations (AVMs) and arteriovenous fistulae. The Optima Coil System is also indicated for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolization in the peripheral vasculature. The Optima Coil System comprises of implant coil and a pusher assembly. The Optima Coil System is designed fr use with the XCEL Detachment Controller. The Optima coil is detached thermally with the XCEL Detachment Controller. · Class 2 · Implant
All models of Optima Coil System (379)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 2
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00818053025891), received between Feb 16, 2021 and May 16, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Premature Separation” (3 reports).
2 FDA recall records name this device's identifier, 2 still open.
2 other recalls cover devices cleared under the same FDA submission (K172390); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Recalls naming this device
- Jan 3, 2024Class IIOpen, Classified
Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the hypotube component of the delivery pusher. Due to the location of the delivery pusher within the delivery system, it is possible for the discoloration to mechanically break off from the delivery pusher, leaving the potential for the material to flow through the delivery system (i.e. microcatheter), and into the patient vasculature causing foreign emboli.
Z-1041-2024 · Root cause: Material/Component Contamination · Recall details · FDA record ↗
- Sep 7, 2022Class IIOpen, Classified
Product pouch label does not match up with carton label
Z-0103-2023 · Root cause: Error in labeling · Recall details · FDA record ↗
Most reported problems
Device problems
- Premature Separation3
- Migration2
- Detachment of Device or Device Component1
- Device Contaminated at the User Facility1
- Nonstandard Device1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- Insufficient Information1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 16, 2025Migration; Premature Separation; Migration; Premature Separation
IT WAS REPORTED THAT: "THE PHYSICIAN PLANNED TO DO A PCOM ANEURYSM CASE. THE PLAN WAS TO USE OPTIMA COILS. AFTER GETTING ACCESS TO THE ANEURYSM TOOK OPTIMA COMPLEX SOFT 4X13AND FOLLOWED WITH OPTIMA COMPLEX SS 3X8. THE PHYSICIAN PACKING THE OPTIMA COMPLEX SS 3X8 COIL AND SOMEMOVENT COIL NO MOVEMENT PREMATURELY DETACHED AND COIL MIGRATED TO THE ICA BIFURCATION. THE PHYSICIAN TRYING TO OUT PREMATURE COIL BUT HE FACING SOME DIFFICULTIES AND AFTER THAT THE PHYSICIAN USED STENTRETRIVER AND REMOVED THE COIL.THE PHYSICIAN TOOK ANOTHER OPTIMA COIL FINISHED THE CASE. THE CASE WENT OFF WELL AND THE PATIENT IS DOING FINE." INCIDENT REPORT FORM SUBMITTED FOR THIS COMPLAINT INDICATES THAT NO PATIENT INJURY WAS SUSTAINED. UPDATE 22APR2025- ADDITIONAL INFORMATION RECEIVED FROM THE ISSUER: "1. DID THE PROCEDURE INVOLVE TORTUOUS ANATOMY? NO 2. WILL THE MICROCATHETER BE AVAILABLE FOR RETURN? NO 3. WHERE DID THE IMPLANT PREMATURELY DETACH? (INSIDE THE AN, INSIDE THE MC?, ETC) PARTIALLY DEPLOYED IN THE COIL ANEURYSM AND ONE LOOP CAME OUT AND PHYSICIAN TRYING TO PULL BACK NO MOVEMENT. 4. WERE ANY ATTEMPTS MADE TO DETACH THE IMPLANT COIL USING THE DETACHMENT CONTROLLER? NO 5. CAN YOU CONFIRM IF THE DEVIC
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22038663 ↗MalfunctionApr 24, 2024Nonstandard Device; Nonstandard Device
ON MARCH 18TH, A COMPLAINT WAS RECEIVED FROM A CUSTOMER INDICATING THAT THEY ENCOUNTERED VISIBILITY ISSUES DURING THE USE OF AN OPTIMA COIL SYSTEM WHEN ATTEMPTING TO VISUALIZE THE RO COIL COMPONENT OF THE DELIVERY PUSHER UNDER FLUOROSCOPIC GUIDANCE. THIS WAS THE 5TH COMPLAINT THROUGH 2024 WHICH WAS RECEIVED FOR THIS SAME ISSUE, AND UPON ADDITIONAL INVESTIGATION, IT WAS DISCOVERED THAT THE SAME HYPOCOIL SUBASSEMBLY LOT NUMBER WAS USED IN THE MANUFACTURING OF THESE UNITS. THIS HYPOCOIL SUBASSEMBLY LOT (S221000089) WAS MANUFACTURED BY AN EXTERNAL SUPPLIER ACCORDING TO THE MANUFACTURING RECORDS. TO DATE, ALL COMPLAINT CASES INVOLVING VISIBILITY ISSUES FROM THIS HYPOCOIL SUBASSEMBLY LOT NUMBER HAVE RESULTED IN NO PATIENT HARM AND REQUIRED THE USER TO REPLACE THE UNIT WITH A NEW COIL SYSTEM TO COMPLETE THE PROCEDURE. DUE TO THE SIMILARITY IN SUBASSEMBLY LOT NUMBER, TWO OF THESE COMPLAINT UNIT SAMPLES WERE SENT FOR MATERIAL ANALYSIS TO AN EXTERNAL VENDOR. ON 29MAR2024, THE RESULTS OF THIS THIRD-PARTY MATERIAL ANALYSIS WAS RECEIVED WHICH REVEALED THAT THE IMPLICATED SECTION WHERE THE PURPORTED RO COIL WOULD BE WELDED TO THE SSTL PORTION OF THE DEVICE WAS IN-FACT NOT THE INTENDED COIL WIRE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19176982 ↗MalfunctionOct 25, 2023Premature Separation; Premature Separation
IT WAS REPORTED THAT: "THE PHYSICIAN HAD A PREMATURE DETACHMENT OF AN OPTIMA 3MM X 8CM. USING AN SL-10 95 DEGREE MICROCATHETER, THE PHYSICIAN DEPLOYED 2 COILS INTO A 6MM PCOM ANEURYSM (ONE 6X15CM ORBIT AND ONE 5X10CM OPTIMA CSS). FOR THE 3RD COIL, THE PHYSICIAN PREPPED OUR 3X8 CSS PER DFU AND ADVANCED THROUGH CATHETER WITHOUT ISSUE. SINCE THE COIL DID NOT SIT AS HE NEEDED, THE PHYSICIAN TRIED REPOSITIONING THE 3X8 OPTIMA CSS AND UPON REPOSITIONING, IT PREMATURELY DETACHED. HE FORTUNATELY HAD ENOUGH OF THE COIL IN THE MICROCATHETER THAT ALLOWED HIM TO SAFELY PULL THE MICROCATHETER OUT OF THE BODY. AS THEY PULLED THE MICROCATHETER OUT, A SMALL LOOP OF THE PREVOIUS COIL HERNIATED OUT OF THE ANEURYSM. THEY FELT CONFIDENT THAT THIS SMALL LOOP WOULD NOT POSE A SAFETY RISK. THE CONCLUDED THE CASE WITH A TOTAL OF JUST TWO COILS IMPLANTED. NO PATIENT INJURY OCCURED DURING PROCEDURE." INCIDENT REPORT FORM SUBMITTED FOR THIS COMPLAINT INDICATES THAT NO PATIENT INJURY WAS SUSTAINED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18003348 ↗MalfunctionAug 18, 2023Device Contaminated at the User Facility; Device Contaminated at the User Facility
IT WAS REPORTED THAT: "THERE WAS FOREIGN MATTER INSIDE THE COIL SHEATH" INCIDENT REPORT FORM RECEIVED FOR THIS COMPLAINT INDICATED NO PATIENT INJURY WAS SUSTAINED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17572764 ↗MalfunctionJan 25, 2022Migration; Premature Separation; Migration; Premature Separation
IT WAS REPORTED THAT: "AFTER INSERTING THE COIL, THE SHAPE AND LOCATION WERE UNSATISFACTORY, SO RECAPTURE WAS TRIED TWICE. WHEN RECAPTURE WAS TRIED AGAIN, THE COIL DID NOT MOVE. WHEN CHECKED IT WAS FOUND THAT IT WAS PRE-DETACHED." 05JAN2022 UPDATE - ADDITIONAL INFORMATION RECEIVED FROM ISSUER: "DURING DEPLOYMENT OF THE COMPLEX SUPER SOFT 3X8 COIL, THE LOOP KEPT COMING OUT OF THE ANEURYSM. THE MICROCATHETER WAS INSERTED IN AND OUT 3 TIMES. THE COIL DID NOT MOVE, AND WHEN CHECKED, IT WAS FOUND TO BE PRE-DETACHED. THE COIL WAS LEFT INSIDE THE MICROCATHETER. THE PUSHER WIRE OF THE COIL WAS USED TO PUSH THE COIL THAT WAS INSIDE THE MICROCATHETER INTO THE ANEURYSM. THE COIL REMAINING IN THE MICROCATHETER WAS INSERTED INTO THE ANEURYSM AS MUCH AS POSSIBLE, BUT THE PROXIMAL PART OF THE COIL COULD NO LONGER BE INSERTED, SO THE SAME STENT WAS DEPLOYED IN THE COIL ASSISTANT STENT (STRYKER ATLAS) THAT WAS PREVIOUSLY DEPLOYED IN THE PARENT ARTERY SO THAT THE COIL LOOP DOES NOT INJURE THE ARTERY AND PROCEDURE WAS FINISHED. THE FINAL ANGIO PHOTO AFTER THE SURGERY SHOWS THE PATIENT HAD NO SERIOUS INJURIES."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13343169 ↗MalfunctionFeb 16, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
REPORT SENT TO FDA BY USER FACILITY: "DURING ANEURYSM COILING COIL DETACHED WITHOUT BEING RELEASED BY PROVIDER."
Patient problems: Insufficient Information
MAUDE report 11334038 ↗
FDA clearance and classification
Cleared through 510(k) K172390 on Feb 18, 2018 (decision: Substantially Equivalent). Submitted by Blockade Medical, LLC (D.B.A. Balt Usa) as “Optima Coil System”. The FDA review took 194 days. FDA record ↗
The FDA regulates product code HCG (device, neurovascular embolization) under 21 CFR 882.5950 as a Class II device. 21 CFR 882.5950 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K172390. One submission often covers many models, so check the product and lot details in each record.
- Z-1988-2025 · May 8, 2025 · Open, ClassifiedOptima Coil System REFs/UDI-DI codes: OPTI0156BLK 00810068568875 OPTI0158BLK 00810068568882 OPTI0103BLK 00810068568851 OPTI0258BLK 00810068568929 OPTI0212BLK 00810068568912 OPTI020
- Z-1680-2022 · Jul 26, 2022 · Open, ClassifiedOptima Coil System Model OPTI0520CSF10. For endovascular embolization.
Common questions about the Optima Coil System OPTI0308CSS10
Has the Optima Coil System OPTI0308CSS10 been recalled?
Yes. 2 FDA recall records name this device's identifier: 2 still open. The most recent, Z-1041-2024 (Class II), began on Jan 3, 2024: Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
What problems have been reported with the Optima Coil System OPTI0308CSS10?
The FDA's MAUDE database lists 6 adverse event reports for this device, received between Feb 16, 2021 and May 16, 2025. In those reports, the most common specific device problems are “Premature Separation” (3), “Migration” (2) and “Detachment of Device or Device Component” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Optima Coil System OPTI0308CSS10?
None of the reports are classified as deaths, 0 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Optima Coil System OPTI0308CSS10 FDA approved?
It was cleared through 510(k) K172390 on Feb 18, 2018. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the Optima Coil System OPTI0308CSS10 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the Optima Coil System OPTI0308CSS10, and is it still sold?
The FDA's device database lists Balt USA LLC as the company responsible for it (brand Optima Coil System, model OPTI0308CSS10). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Device, Neurovascular Embolization devices
- POD RBYPODJ60-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION355 reports
- Penumbra System SCH1Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION295 reports
- RUBY Coil RBY4C0860-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION276 reports
- Smart Coil 400SMTHXSFT0208Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION165 reports
- Penumbra System RH1-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION154 reports
- Optima Coil System OPTI0208CSS10Balt USA LLC · Device, Neurovascular Embolization3 recalls3 reports
- POD RBYPOD6-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION148 reports
- POD RBYPODJ30-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION132 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.