RxSight Light Adjustable Lens (RxLAL) 60005-3230Recalls & reported problems
Rxsight, Inc. · LAL, Sterile, Packaged, 23.0 Diopter · Class 3 · Implant
All models of RxSight Light Adjustable Lens (RxLAL) (62)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 21
- Deaths reported
- 0
- Injuries reported
- 20
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 21 adverse event reports that list this exact device (DI 00818806020739), received between Aug 15, 2022 and Jul 31, 2026 — classified as 20 injuries, 1 malfunction.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem15
- Insufficient Device Problem Information2
- Optical Decentration1
- Optical Problem1
- Patient-Device Incompatibility1
- Use of Device Problem1
Patient problems
- Blurred Vision8
- Visual Disturbances6
- Capsular Bag Tear3
- Visual Impairment3
- No Clinical Signs, Symptoms or Conditions2
- Unspecified Eye / Vision Problem2
- Diplopia/Double Vision1
- Insufficient Information1
Recent adverse event reports
The 21 most recent of 21 reports, in the reporter's own words as published by the FDA.
InjuryJul 31, 2026Adverse Event Without Identified Device or Use Problem
A site reported to RxSight that patient's Light Adjustable Lens (LAL) was explanted from the right eye due to blurry vision and visual disturbances. No additional information has been provided.
Patient problems: Blurred Vision; Visual Disturbances
MAUDE report 50105318 ↗InjuryApr 21, 2026Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL) WAS IMPLANTED ON (B)(6) 2023 IN THE RIGHT EYE. POSTOPERATIVELY, THE PATIENT COMPLETED ALL LIGHT TREATMENTS; THE RIGHT EYE WAS TARGETED FOR NEAR VISION AND THE LEFT EYE FOR DISTANCE. ON (B)(6) 2026, THE PATIENT'S LAL WAS EXPLANTED FROM THE RIGHT EYE DUE TO THE PATIENT'S DISSATISFACTION WITH THE CHOSEN REFRACTIVE TARGET, VISUAL DISTURBANCES AND MONOCULAR DIPLOPIA. POSTOPERATIVELY, THE PATIENT WAS REPORTED TO BE SATISFIED WITH THEIR VISION AND NO LONGER WAS EXPERIENCING VISUAL DISTURBANCES. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: Diplopia/Double Vision; Visual Disturbances
MAUDE report 24944978 ↗InjuryMar 31, 2026Use of Device Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT WAS IMPLANTED WITH THE LIGHT ADJUSTABLE LENS (LAL, SN: (B)(6), +23.0D) IN THE LEFT EYE. THE PATIENT COMPLETED 5 LIGHT ADJUSTMENTS POST-OPERATIVELY BUT DID NOT COMPLETE THE REQUIRED LOCK IN TREATMENTS. ON (B)(6) 2026, APPROXIMATELY 26 MONTHS LATER, THE PATIENT RETURNED TO CLINIC COMPLAINING OF BLURRY VISION AND VISUAL DISTURBANCES. THE LAL WAS SUBSEQUENTLY EXPLANTED ON (B)(6) 2026.
Patient problems: Blurred Vision; Visual Disturbances
MAUDE report 24743631 ↗MalfunctionFeb 27, 2026Insufficient Device Problem Information
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, (B)(6), +23.0D) WAS IMPLANTED BACKWARDS DURING PRIMARY CATARACT SURGERY. THE LAL WAS REMOVED AND ANOTHER LAL WAS IMPLANTED AS A REPLACEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24466119 ↗InjuryFeb 18, 2026Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A CAPSULE TEAR OCCURRED DURING IMPLANTATION OF A LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D). THE LENS WAS PLACED IN THE SULCUS.
Patient problems: Capsular Bag Tear
MAUDE report 24379257 ↗InjuryNov 21, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D) WAS EXPLANTED FROM THE RIGHT EYE DUE TO BLURRY VISION. A NEW LAL WAS IMPLANTED AS A REPLACEMENT.
Patient problems: Blurred Vision
MAUDE report 23623904 ↗InjuryNov 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D) WAS EXPLANTED DUE TO PATIENT DISSATISFACTION WITH VISUAL OUTCOME.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23500412 ↗InjuryNov 6, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A CAPSULE TEAR OCCURRED DURING IMPLANTATION OF THE LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D). THE LAL HAPTICS WERE PLACED IN THE SULCUS WITH OPTIC CAPTURE.
Patient problems: Capsular Bag Tear
MAUDE report 23490416 ↗InjuryOct 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D) WAS EXPLANTED FROM THE LEFT EYE DUE TO VISUAL DISTURBANCES AND BLURRED VISION. A NEW LAL WAS IMPLANTED AS A REPLACEMENT.
Patient problems: Blurred Vision; Visual Disturbances
MAUDE report 23381144 ↗InjuryOct 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D) WAS EXPLANTED DUE TO BLURRED VISION.
Patient problems: Blurred Vision
MAUDE report 23381141 ↗InjuryAug 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, SN (B)(6)+23.0D) WAS EXPLANTED FROM THEIR LEFT EYE DUE TO BLURRY VISION. A NEW LAL (SN (B)(6), +23.0D) WAS IMPLANTED AS A REPLACEMENT.
Patient problems: Blurred Vision
MAUDE report 22840957 ↗InjuryJul 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D) WAS EXPLANTED DUE TO VISUAL DISTURBANCES AND PATIENT DISSATISFACTION WITH CHOSEN REFRACTIVE TARGET.
Patient problems: Blurred Vision
MAUDE report 22420234 ↗InjuryJun 26, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, (B)(6), +23.0D) WAS EXPLANTED DUE TO VISUAL DISTURBANCES AND BLURRED VISION AND A NEW LAL (B)(6), +23.0D) IMPLANTED AS A REPLACEMENT.
Patient problems: Blurred Vision; Visual Disturbances
MAUDE report 22342612 ↗InjuryMay 21, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D) WAS EXPLANTED DUE TO PATIENT DISSATISFACTION WITH THE CHOSEN REFRACTIVE TARGET.
Patient problems: Insufficient Information
MAUDE report 22063326 ↗InjuryJan 21, 2025Optical Decentration; Optical Decentration
A SITE REPORTED TO RXSIGHT THAT DURING PRIMARY CATARACT SURGERY, ON (B)(6) 2024, AFTER DELIVERY OF THE LIGHT ADJUSTABLE LENS (LAL, (B)(6), +23D) IN THE PATIENT'S EYE, IT WAS OBSERVED THAT A HAPTIC HAD DISINSERTED. AN ADDITIONAL PROCEDURE WAS COMPLETED ON 12/26/2024 TO EXPLANT THE LAL AND IMPLANT A NEW LAL ((B)(6), +24D) AS A REPLACEMENT.
Patient problems: Unspecified Eye / Vision Problem
MAUDE report 21198769 ↗InjurySep 20, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT WITH HISTORY OF BILATERAL RADIAL KERATOTOMY AND CORNEAL EDEMA UNDERWENT EXPLANTATION OF A LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D) IN THEIR LEFT EYE. THE LAL WAS IMPLANTED ON (B)(6) 2024. THE PATIENT COMPLAINED OF VISUAL DISTURBANCE PRIOR TO THE FIRST LIGHT ADJUSTMENT ON (B)(6) 2024, WHICH PERSISTED UP TO THE EXPLANT DATE. A NEW LAL (SN (B)(6), +22.5D) WAS IMPLANTED AS A REPLACEMENT. RXSIGHT'S FIRST AWARENESS OF THIS EVENT WAS ON 08/23/2024. REFERENCE REPORT #3012712027-2024-00166 FOR THE REPORT ON THE RIGHT EYE.
Patient problems: Visual Disturbances
MAUDE report 20274070 ↗InjuryAug 21, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +23.0D) WAS EXPLANTED FROM THE PATIENT'S LEFT EYE DUE TO RESIDUAL REFRACTIVE ERRORS; A NEW LAL (SN (B)(6), +23.0D) WAS IMPLANTED AS A REPLACEMENT. RXSIGHT'S FIRST AWARENESS OF THIS EVENT WAS ON 07/24/2024.
Patient problems: Visual Impairment
MAUDE report 20020474 ↗InjuryJun 25, 2024Patient-Device Incompatibility; Patient-Device Incompatibility
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, SN (B)(6) WAS EXPLANTED DUE TO REFRACTIVE SURPRISE AND A NEW LAL (SN (B)(6) IMPLANTED AS A REPLACEMENT. RXSIGHT'S FIRST AWARENESS OF THIS EVENT WAS ON (B)(6) 2024.
Patient problems: Visual Impairment
MAUDE report 19610861 ↗InjuryApr 12, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A SITE REPORTED TO RXSIGHT THAT DURING PRIMARY CATARACT SURGERY, A CAPSULAR BAG TEAR WAS NOTED. AN ATTEMPT WAS MADE TO IMPLANT 2 LIGHT ADJUSTABLE LENSES (LAL, SERIAL NUMBERS (B)(6)), HOWEVER, THE ATTEMPTS WERE UNSUCCESSFUL. A VITRECTOMY WAS PERFORMED AND A 3RD LAL WAS IMPLANTED SUCCESSFULLY. RXSIGHT'S FIRST AWARENESS OF THIS EVENT WAS ON 03/15/2024.
Patient problems: Capsular Bag Tear
MAUDE report 19102126 ↗InjuryMar 29, 2024Insufficient Device Problem Information; Insufficient Device Problem Information
A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS (LAL, SN (B)(6)) WAS IMPLANTED BACKWARDS DURING PRIMARY CATARACT SURGERY. AN ADDITIONAL SURGICAL PROCEDURE WAS COMPLETED TO EXPLANT THE LAL AND IMPLANT A NEW LAL (SN (B)(6)) IN THE CORRECT ORIENTATION. RXSIGHT'S FIRST AWARENESS OF THIS EVENT WAS ON (B)(6) 2024.
Patient problems: Unspecified Eye / Vision Problem
MAUDE report 19005875 ↗InjuryAug 15, 2022Optical Problem; Optical Problem
SITE REPORTED THAT THE LIGHT ADJUSTABLE LENS WAS EXPLANTED AS THE PATIENT WAS UNHAPPY WITH THE VISUAL OUTCOME DUE TO UNRESOLVED RESIDUAL ASTIGMATISM AFTER 3 ADJUSTMENTS. RXSIGHT'S FIRST AWARENESS OF THIS EVENT WAS (B)(6) 2022.
Patient problems: Visual Impairment
MAUDE report 15230254 ↗
FDA clearance and classification
Approved through premarket approval (PMA) P160055 on Nov 22, 2017. Submitted by Rxsight, Inc. as “Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)”. The FDA review took 348 days. The FDA has since approved 49 supplements (changes to the device or its labeling), most recently on Nov 5, 2026. FDA record ↗
The FDA regulates product code PZK (light adjustable lens (lal) and light delivery device (ldd)) under 21 CFR 886.3600 as a Class III device. 21 CFR 886.3600 ↗
Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.
FDA definition of this device type: The system consists of an intraocular lens and an external energy source. The lens is intended to be implanted to replace the natural lens of an eye. The external energy source is used to postoperatively alter the properties of the lens material to reduce the likelihood of clinically significant postoperative refractive error.
Common questions about the RxSight Light Adjustable Lens (RxLAL) 60005-3230
Has the RxSight Light Adjustable Lens (RxLAL) 60005-3230 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00818806020739), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the RxSight Light Adjustable Lens (RxLAL) 60005-3230?
The FDA's MAUDE database lists 21 adverse event reports for this device, received between Aug 15, 2022 and Jul 31, 2026. In those reports, the most common specific device problems are “Optical Decentration” (1), “Optical Problem” (1) and “Patient-Device Incompatibility” (1); the most common patient problems are “Blurred Vision” (8), “Visual Disturbances” (6) and “Capsular Bag Tear” (3). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the RxSight Light Adjustable Lens (RxLAL) 60005-3230?
None of the reports are classified as deaths, 20 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the RxSight Light Adjustable Lens (RxLAL) 60005-3230 FDA approved?
It was approved through premarket approval (PMA) P160055 on Nov 22, 2017.
Is the RxSight Light Adjustable Lens (RxLAL) 60005-3230 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the RxSight Light Adjustable Lens (RxLAL) 60005-3230, and is it still sold?
The FDA's device database lists Rxsight, Inc. as the company responsible for it (brand RxSight Light Adjustable Lens (RxLAL), model 60005-3230). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Light Adjustable Lens (Lal) And Light Delivery Device (Ldd) devices
- RxSight Light Adjustable Lens (RxLAL) 60005-3205Rxsight, Inc. · Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)51 reports
- RxSight Light Adjustable Lens (RxLAL) 60005-3200Rxsight, Inc. · Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)47 reports
- RxSight Light Adjustable Lens (RxLAL) 60005-3210Rxsight, Inc. · Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)40 reports
- RxSight Light Adjustable Lens (RxLAL) 60005-3190Rxsight, Inc. · Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)32 reports
- RxSight Light Adjustable Lens (RxLAL) 60005-3195Rxsight, Inc. · Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)31 reports
- Light Adjustable Lens (LAL) 60007-0200Rxsight, Inc. · Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)31 reports
- Light Adjustable Lens (LAL) 60007-0195Rxsight, Inc. · Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)30 reports
- RxSight Light Adjustable Lens (RxLAL) 60005-3215Rxsight, Inc. · Light Adjustable Lens (Lal) And Light Delivery Device (Ldd)30 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page