Light Adjustable Lens (LAL) 60007-0235Recalls & reported problems

Rxsight, Inc. · LAL+, Light Adjustable Lens, Sterile, Packaged, 23.5 Diopter · Class 3 · Implant

All models of Light Adjustable Lens (LAL) (33)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
16
Deaths reported
0
Injuries reported
16
Recalls naming it
0

Summary

The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 00818806021651), received between Sep 4, 2024 and Apr 29, 2026 — classified as 16 injuries.

The most frequently reported specific device problem is “Optical Decentration” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 2 reportsSep 2025: 2 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem13
  • Optical Decentration1
  • Patient-Device Incompatibility1
  • Use of Device Problem1

Patient problems

  • Blurred Vision9
  • Visual Disturbances3
  • Capsular Bag Tear2
  • Diplopia/Double Vision2
  • Visual Impairment1

Recent adverse event reports

The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 29, 2026Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+) WAS EXPLANTED FROM THE RIGHT EYE DUE TO BLURRY DISTANCE VISION. A NEW LAL+ WAS IMPLANTED AS A REPLACEMENT.

    Patient problems: Blurred Vision

    MAUDE report 25032609 ↗
  • InjuryMar 13, 2026Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, (B)(6), +23.5D) WAS EXPLANTED DUE TO MONOCULAR DIPLOPIA AND A NEW LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +21.5D) IMPLANTED AS A REPLACEMENT.

    Patient problems: Diplopia/Double Vision

    MAUDE report 24595973 ↗
  • InjuryMar 12, 2026Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) WAS EXPLANTED FROM THE LEFT EYE DUE TO PATIENT DISSATISFACTION AND BLURRY VISION. THE LAL+ WAS EXPLANTED AND ANOTHER LAL+ (SN (B)(6), +23.5D) WAS IMPLANTED AS A REPLACEMENT.

    Patient problems: Blurred Vision

    MAUDE report 24581825 ↗
  • InjuryDec 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT IMPLANTED WITH THE LIGHT ADJUSTABLE LENS+ (LAL+, SN: (B)(6), +23.5D) WAS DIAGNOSED WITH ACUTE UVEITIS FOLLOWING THE FIRST LIGHT TREATMENT. THE PATIENT WAS TREATED AND RECEIVED TWO ADDITIONAL LIGHT ADJUSTMENTS FOLLOWING RESOLUTION DESPITE A MINIMAL REDUCTION IN BEST CORRECTED VISUAL ACUITY. THE LENS WAS EXPLANTED DUE TO BLURRY VISION AND THE PATIENT'S DISSATISFACTION WITH THE CHOSEN REFRACTIVE TARGET.

    Patient problems: Blurred Vision

    MAUDE report 23705357 ↗
  • InjuryNov 26, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.50) WAS EXPLANTED FROM THE RIGHT EYE DUE TO BLURRY VISION AND BOTH MONOCULAR AND BINOCULAR DIPLOPIA. THE TREATING PHYSICIAN NOTED THE BINOCULAR DIPLOPIA WAS CAUSED BY A DECOMPENSATED PHORIA.

    Patient problems: Diplopia/Double Vision

    MAUDE report 23658801 ↗
  • InjurySep 16, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) WAS EXPLANTED FROM THEIR LEFT EYE DUE TO PATIENT DISSATISFACTION WITH THEIR CHOSEN REFRACTIVE TARGET. A NEW LAL WAS IMPLANTED AS A REPLACEMENT.

    Patient problems: Blurred Vision

    MAUDE report 23068765 ↗
  • InjurySep 16, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) WAS EXPLANTED FROM THEIR RIGHT EYE DUE TO PATIENT DISSATISFACTION WITH THEIR CHOSEN REFRACTIVE TARGET. A NEW LAL WAS IMPLANTED AS A REPLACEMENT.

    Patient problems: Blurred Vision

    MAUDE report 23068739 ↗
  • InjuryAug 25, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) WAS EXPLANTED FROM THEIR LEFT EYE DUE TO BLURRED VISION AND VISUAL DISTURBANCES. THE PATIENT'S SYMPTOMS CONTINUED FOLLOWING LENS REPLACEMENT WITH A NON-LAL IOL.

    Patient problems: Visual Disturbances

    MAUDE report 22891466 ↗
  • InjuryAug 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A BILATERALLY IMPLANTED PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.50D) WAS EXPLANTED FROM THE LEFT EYE DUE TO BLURRY VISION AND A NEW LIGHT ADJUSTABLE LENS (LAL, SN (B)(6), +22.5D) IMPLANTED AS A REPLACEMENT.

    Patient problems: Blurred Vision

    MAUDE report 22798614 ↗
  • InjuryJul 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A LIGHT ADJUSTABLE LENS+ LAL+, SN: (B)(6), +23.5D) WAS EXPLANTED DUE TO BLURRY VISION AND VISUAL DISTURBANCES.

    Patient problems: Blurred Vision; Visual Disturbances

    MAUDE report 22630957 ↗
  • InjuryJul 28, 2025Optical Decentration; Optical Decentration

    A SITE REPORTED TO RXSIGHT THAT A CAPSULE TEAR OCCURRED DURING IMPLANTATION OF THE LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D). THE LAL+ WAS PLACED IN THE SULCUS AND WAS OBSERVED TO BE DISPLACED SUPERIORLY AFTER THE SURGERY. NO FURTHER SURGICAL INTERVENTION WAS REQUIRED AND LIGHT TREATMENTS WERE SUCCESSFULLY PERFORMED.

    Patient problems: Capsular Bag Tear

    MAUDE report 22630805 ↗
  • InjuryMay 7, 2025Patient-Device Incompatibility; Patient-Device Incompatibility

    A SITE REPORTED TO RXSIGHT THAT A LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) WAS EXPLANTED DUE TO AN INCORRECTLY CHOSEN IOL POWER DUE TO PTERYGIUM THAT INTERFERED WITH THE CALCULATION. A NEW LAL+ (SN (B)(6), +10.0D) WITH A DIFFERENT IOL POWER WAS IMPLANTED AS A REPLACEMENT.

    Patient problems: Visual Impairment

    MAUDE report 21981499 ↗
  • InjuryApr 21, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) WAS EXPLANTED DUE TO PATIENT DISSATISFACTION IN VISION WITH THE CHOSEN REFRACTIVE TARGET. A NEW LAL (SN (B)(6), +23.5D) WAS IMPLANTED AS A REPLACEMENT.

    Patient problems: Visual Disturbances

    MAUDE report 21877333 ↗
  • InjuryJan 14, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE SITE REPORTED THAT WHILE THE SURGEON WAS IMPLANTING THE LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) THE LEADING HAPTIC BROKE THE POSTERIOR CAPSULE. AN ANTERIOR VITRECTOMY WAS PERFORMED AND THE LENS WAS PLACED IN THE SULCUS.

    Patient problems: Capsular Bag Tear

    MAUDE report 21149624 ↗
  • InjuryOct 24, 2024Use of Device Problem; Use of Device Problem

    A BILATERALLY IMPLANTED PATIENT'S LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) WAS IMPLANTED IN THE LEFT EYE ON (B)(6) 2023. THE PATIENT UNDERWENT ONE LIGHT ADJUSTMENT AND DID NOT COMPLETE REMAINING LIGHT TREATMENTS. THE PATIENT SELF-REPORTED NOT FOLLOWING THE REQUIREMENTS FOR WEARING RXSIGHT UV SPECTACLES DURING THE POST-OPERATIVE PERIOD. THE LAL+ WAS EXPLANTED ON (B)(6) 2024, APPROXIMATELY 9 MONTHS AFTER THE IMPLANT SURGERY, DUE TO BLURRY VISION. AN INTRAOCULAR LENS FROM A DIFFERENT MANUFACTURER WAS IMPLANTED AS A REPLACEMENT.

    Patient problems: Blurred Vision

    MAUDE report 20527978 ↗
  • InjurySep 4, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SITE REPORTED TO RXSIGHT THAT A LIGHT ADJUSTABLE LENS+ (LAL+, SN (B)(6), +23.5D) WAS EXPLANTED ON (B)(6) 2024 DUE TO LENS DECENTRATION. NO LIGHT TREATMENTS WERE PERFORMED PRIOR TO EXPLANTATION. AN INTRAOCULAR LENS FROM A DIFFERENT MANUFACTURER WAS IMPLANTED AS REPLACEMENT. RXSIGHT'S FIRST AWARENESS OF THE EVENT WAS ON 08/05/2024.

    Patient problems: Blurred Vision

    MAUDE report 20137552 ↗

Other Light Adjustable Lens (Lal) And Light Delivery Device (Ldd) devices

All Light Adjustable Lens (Lal) And Light Delivery Device (Ldd) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page