The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00827002014022), received between Nov 16, 2017 and Dec 14, 2018 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Component Missing1
- Crack1
- Failure to Advance1
- Material Deformation1
- Split1
Patient problems
- No Known Impact Or Consequence To Patient3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 14, 2018Crack; Component Missing; Failure to Advance
THE COMPLAINANT REPORTED THAT THE TIP OF THE DILATOR WAS DAMAGED DURING THE PHYSICIAN'S ATTEMPT TO ADVANCE IT OVER THE WIRE GUIDE. AS A RESULT, ANOTHER DEVICE (UNKNOWN LOT NUMBER) OF THE SAME KIND WAS USED TO COMPLETE THE PROCEDURE. IT WAS FURTHER NOTED THAT THERE WAS A CRACK IN THE TIP OF THE DILATOR, AND A PIECE OF THE DILATOR TIP WAS MISSING. THE COMPLAINANT REPORTED THAT THE MISSING TIP WAS NOT IN THE PATIENT'S BODY. ADDITIONALLY, THE PRODUCT PROBLEM DID NOT RESULT IN ANY REPORTED SERIOUS INJURIES TO THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8166482 ↗MalfunctionDec 14, 2018Break
THE COMPLAINANT REPORTED THAT THE TIP OF THE DILATOR WAS DAMAGED DURING THE PHYSICIAN'S ATTEMPT TO ADVANCE IT OVER THE WIRE GUIDE. AS A RESULT, ANOTHER DEVICE OF THE SAME KIND WAS USED TO COMPLETE THE PROCEDURE. IT WAS FURTHER NOTED THAT THERE WAS A CRACK IN THE TIP OF THE DILATOR. THE PRODUCT PROBLEM DID NOT RESULT IN ANY REPORTED SERIOUS INJURIES TO THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8166395 ↗MalfunctionNov 16, 2017Split; Material Deformation; Split; Material Deformation
THE INTERNATIONAL CUSTOMER REPORTED THAT, WHEN THE DILATOR WAS ADVANCED OVER A WIRE GUIDE OF UNKNOWN MANUFACTURE, THERE WAS AN UNUSUAL FEELING FEEDBACK WAS FELT. WHEN THE OPERATOR CHECKED THE TIP OF THE DILATOR, A DEFORMATION/SPLIT WAS EVIDENT IN THE TIP OF THE DEVICE. ANOTHER DEVICE WAS USED INSTEAD TO COMPLETE THE PROCEDURE SUCCESSFULLY, WITH NO FURTHER ISSUES AND NO PATIENT ADVERSE EVENTS. THE DEVICE HAS BEEN RETURNED FOR EVALUATION; HOWEVER, AS OF THE DATE OF THIS REPORT, THE INVESTIGATION IS STILL PENDING.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7039540 ↗
Other DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION devices
- VersaCross Connect LAAC Access Solution VXAK0007Baylis Médicale Cie Inc · Dilator, Vessel, For Percutaneous Catheterization3 deaths108 reports
- TandemLife 5740-2417Cardiacassist, Inc. · Dilator, Vessel, For Percutaneous Catheterization2 recalls0 reports
- TightRail Rotating Dilator Sheath 545-513Spectranetics Corporation · Dilator, Vessel, For Percutaneous Catheterization20 deaths74 reports
- VersaCross Connect LAAC Access Solution VXAK0003Baylis Médicale Cie Inc · Dilator, Vessel, For Percutaneous Catheterization2 deaths70 reports
- VersaCross Connect LAAC Access Solution VXAK0007Baylis Médicale Cie Inc · Dilator, Vessel, For Percutaneous Catheterization2 deaths54 reports
- AVANTI 504656XCordis Corporation · DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION1 recall2 reports
- Abiomed® 00884450732311Merit Medical Systems, Inc. · Dilator, Vessel, For Percutaneous Catheterization1 recall1 report
- Mini Stick MAX H965457510Angiodynamics, Inc. · DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page