Cook G03282Recalls & reported problems

Cook Incorporated · Pericardiocentesis Set · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00827002032828), received between Jul 26, 2016 and Mar 24, 2020 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Aspiration Issue” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Aspiration Issue1
  • Difficult to Remove1
  • Fluid/Blood Leak1

Patient problems

  • No Consequences Or Impact To Patient1
  • No Known Impact Or Consequence To Patient1
  • No Patient Involvement1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 24, 2020Fluid/Blood Leak; Fluid/Blood Leak

    NO ADDITIONAL INFORMATION REGARDING PATIENT AND/OR EVENT DETAILS HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.

    Patient problems: No Patient Involvement

    MAUDE report 9873689 ↗
  • MalfunctionApr 3, 2019Difficult to Remove; Difficult to Remove

    IT WAS REPORTED THAT THE WIRE GUIDE OF A COOK PERICARDIOCENTESIS CATHETER SET WAS UNABLE TO BE WITHDRAWN FROM THE CATHETER DURING AN UNKNOWN PROCEDURE. THE PHYSICIAN HAD TO REMOVE BOTH THE CATHETER AND THE WIRE GUIDE AT THE SAME TIME. ADDITIONAL INFORMATION REGARDING EVENT DETAILS HAVE BEEN REQUESTED, BUT IS UNAVAILABLE AT THIS TIME.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8479832 ↗
  • MalfunctionJul 26, 2016Aspiration Issue; Aspiration Issue

    IT WAS REPORTED DURING A PERICARDIAL DRAINAGE FLUID PROCEDURE THAT AIR WAS ASPIRATED INSTEAD OF FLUID IN THE PERICARDIUM. A SYRINGE WAS ATTACHED TO ANOTHER PORT OF THE SAME THREE-WAY STOPCOCK TO RE-TRY THE ASPIRATION OF FLUID FROM THE PERICARDIUM. THUS, RESULTING IN SUCCESSFUL ASPIRATION. THE PROCEDURE WAS FINISHED WITH THE DEVICE. THERE WERE NOT ANY REPORTED ADVERSE EVENTS TO THE PATIENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 5821906 ↗

Other CATHETER, IRRIGATION devices

All CATHETER, IRRIGATION devices →