Skip to content

Gianturco-Rosch Cook-Z G08553Recalls & reported problems

Cook Incorporated · Cook-Z Stent Gianturco-Rosch Tracheobronchial Design · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002085534), received between Apr 8, 2022 and Apr 8, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 8, 2022Break; Break

    AS REPORTED, A COOK-Z GIANTURCO-ROSCH TRACHEOBRONCHIAL STENT FRACTURED IN THE INFERIOR VENA CAVA (IVC). THE PROCEDURE INVOLVED RETRIEVAL OF A CELECT PLATINUM IVC FILTER, THROMBECTOMY OF THE IVC AND BILATERAL ILIAC VEINS, PLACEMENT OF KISSING ILIAC VEIN STENTS, AND PLACEMENT OF STENTS WITHIN THE IVC. A VENOUS THROMBECTOMY WAS PERFORMED IN THE LEFT ILIAC VEIN AND IVC, JUST BELOW THE FILTER. BILATERAL ACCESS WAS OBTAINED, AND A THROMBECTOMY WAS PERFORMED ON THE RIGHT SIDE. RIGHT JUGULAR ACCESS WAS THEN OBTAINED, AND THE IVC FILTER WAS RETRIEVED, USING A LOOP-TECHNIQUE WITH A 16 FRENCH SHEATH. A THROMBECTOMY OF THE IVC WAS THEN PERFORMED. DESPITE REPEATED ADVISEMENT BY A COOK REPRESENTATIVE THAT THE DEVICE WAS NOT INTENDED FOR VASCULAR USE, THE USER THEN PLACED TWO COOK-Z GIANTURCO-ROSCH TRACHEOBRONCHIAL STENTS IN THE MID-TO-DISTAL IVC VIA RIGHT FEMORAL ACCESS. OTHER MANUFACTURERS¿ 18-MILLIMETER AND 22-MILLIMETER BALLOONS WERE USED TO POST-DILATE THE STENTS. TWO COOK ZILVER STENTS WERE THEN SIMULTANEOUSLY PLACED IN THE RIGHT AND LEFT ILIAC VEINS, KISSING THE INFERIOR Z-STENT THAT WAS DEPLOYED IN THE IVC. ANOTHER MANUFACTURER¿S BALLOONS WERE THEN SIMULTANEOUSLY INFLATED WITHIN THE ZILVE

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14052407 ↗

Other Prosthesis, tracheal, expandable devices

All Prosthesis, tracheal, expandable devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page