Biodesign G23653Recalls & reported problems
Cook Biotech Incorporated · Biodesign Enterocutaneous Fistula Plug · Class 2 · Implant
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002236530), received between Nov 14, 2023 and Nov 14, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Separation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Material Separation1
Patient problems
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 14, 2023Material Separation; Material Separation
ON (B)(6) 2023, A BIODESIGN ENTEROCUTANEOUS FISTULA PLUG WAS PLACED FOR REPAIR OF AN ENTEROCUTANEOUS FISTULA. THE PATIENT HAD THE ANAL CUTANEOUS FISTULA FOR OVER A YEAR. THE FISTULA EXITED OUT OF THE GLUTEUS. THERE WAS NO DISTAL OBSTRUCTION. THE PATIENT HAD NO HISTORY OF RECEIVING RADIATION. THE FISTULA DRAINED LESS THAN 20 ML/DAY. THE FISTULA TRACT WAS 11 CM IN LENGTH AND AROUND 2 MM IN DIAMETER. THERE WERE NO 4 MM PLUG SETS AVAILABLE AT THE IMPLANTING FACILITY. THE PHYSICIAN MADE THE DECISION TO IMPLANT A 7 MM PLUG. THE PLUG WAS SUCCESSFUL AT HEALING THE FISTULA HOWEVER, THE FLANGE WOULD NOT PASS ON ITS OWN WHICH CAUSED THE PATIENT TO EXPERIENCE PAIN. THE PAIN WAS NEAR THE PATIENT'S RECTUM AND OCCURRED WHEN PRESSURE WAS APPLIED. ON (B)(6) 2023, THE PHYSICIAN ATTEMPTED TO LAPAROSCOPICALLY REMOVE THE FLANGE. DUE TO THE LOCATION OF THE FLANGE,NEAR THE RECTUM RIGHT NEXT TO OR POSSIBLY ON THE SPHINCTER, THE FLANGE WAS REMOVED MANUALLY. THE PATIENT DID NOT EXPERIENCE ANY ADDITIONAL COMPLICATIONS OR HARM. UPON EXAMINATION OF THE EXPLANTED FLANGE, THE PHYSICIAN NOTICES THAT THE SILICONE HAD PARTIALLY SEPARATED FROM THE NITINOL RING.
Patient problems: Pain
MAUDE report 18134912 ↗
Other Mesh, surgical devices
- MEDPOR TITAN 81032Stryker Leibinger GmbH & Co. KG · Mesh, surgical1 recall1 report
- Peri-Guard PC1016NSynovis Life Technologies, Inc. · Mesh, surgical1 recall1 report
- Supple Peri-Guard SPG0404Synovis Life Technologies, Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-403-001Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-300-006Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-300-019Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-001-009Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
- SurgiMend® 606-004-105Tei Biosciences Inc. · Mesh, surgical1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.