Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00827002250826), received between Jun 4, 2025 and Jun 4, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Detachment of Device or Device Component1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 4, 2025Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem; Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem

    A PACEMAKER LEAD WAS PLACED IN THE RIGHT ATRIUM AND THE RIGHT VENTRICLE (RV), RESPECTIVELY, FROM THE LEFT CHEST AND A POCKET INFECTION WAS NOTED AFTER 7 YEARS. FIRSTLY, THE RV LEAD WAS ATTEMPTED TO BE REMOVED. AN EVOLUTION® SHORTIE RL CONTROLLED-ROTATION DILATOR SHEATH SET (EVN-SH) WAS USED TO ABOUT THE ANONYMOUS VEIN AND THEN A GLIDELIGHT12 WAS USED. HOWEVER, THE GLIDELIGHT12 WAS UNABLE TO ADVANCE AT ALL ABOUT FROM THE RIGHT ATRIUM (RA) SUPERIOR VENA CAVA (SVC) JUNCTION. THE USER DETERMINED THE ADHESION STRONG AND USED EVOLUTION® RL CONTROLLED-ROTATION DILATOR SHEATH SET (EVN) AT THE BEGINNING, BUT THE PEELING OF THE SHEATH WAS NOT SUFFICIENT, THEREFORE, THE USER COVERED THE EVN WITH A STEADYSHEATH® EVOLUTION® TISSUE STABILIZATION SHEATH (TSS) AND REMOVED THE RV LEAD USING THE EVN. SECONDLY, THE USER ATTEMPTED TO APPROACH THE RA LEAD. THE USER PEELED TO ABOUT THE ANONYMOUS VEIN WITH THE EVN-SH, AND THEN THE USER COVERED THE EVN WITH THE TSS LIKE THE RV LEAD REMOVAL AND ATTEMPTED PEELING. HOWEVER, THE SHEATH HAD DIFFICULTY IN ADVANCING AT RA SVC JUNCTION. THEREFORE, THE USER ONCE ATTEMPTED TO REMOVE THE EVN AND THE TSS FROM THE ANATOMY, AND DURING THIS ATTEMPT, THE METAL PART OF TH

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22140170 ↗

Other DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION devices

All DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION devices →