Cook Vandergrift Inc. · SteadySheath 11 Fr Evolution Tissue Stabilization Sheath · Class 2

Adverse event reports
2
Deaths reported
1
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00827002250833), received between Sep 10, 2024 and Jun 9, 2025 — classified as 1 death, 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Break1
  • Separation Problem1

Patient problems

  • Great Vessel Perforation1
  • Low Blood Pressure/ Hypotension1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • DeathJun 9, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    WE REPORT A CASE IN WHICH SUPERIOR VENA CAVA (SVC) INJURY OCCURRED USING THE FOLLOWING PRODUCTS: EVOLUTION RL CONTROLLED-ROTATION DILATOR SHEATH SET, STEADYSHEATH EVOLUTION® TISSUE STABILIZATION SHEATH, PHILIPPS/GLIDELIGHT 14FR, PHILIPPS/GLIDELIGHT 16FR, (IT IS UNCLEAR IN WHAT ORDER THE COOK PRODUCT EVOLUTION AND THE PHILIPS PRODUCT GLIDELIGHT WERE USED.). EACH ONE LEAD HAD BEEN PLACED IN THE RIGHT ATRIUM AND RIGHT VENTRICLE. AFTER REMOVAL OF THE ATRIAL LEAD, DURING DISSECTION OF THE AREA AROUND THE SVC FOR REMOVAL OF THE VENTRICULAR LEAD, THE PATIENT BLED AND BECAME HYPOTENSIVE; AN ATTEMPT WAS MADE TO STOP THE BLEEDING WITH A PHILIPPS/BRIDGE OCCULUSION BALLOON, FOLLOWED BY OPEN CHEST SURGERY, WHICH REVEALED AN INJURY OF THE SVC.

    Patient problems: Great Vessel Perforation; Low Blood Pressure/ Hypotension

    MAUDE report 22166008 ↗
  • InjurySep 10, 2024Break; Adverse Event Without Identified Device or Use Problem; Separation Problem; Break; Adverse Event Without Identified Device or Use Problem; Separation Problem

    MEDICAL HISTORY: UNKNOWN. INFECTIOUS DISEASE: YES, BUT DETAILS UNKNOWN. APPROACH VIA LEFT SUBCLAVIAN VEIN, PLANNING TO USE IT FOR RV LEAD. WHEN LR-TSS-11.0 WAS SET ON EVOLUTION11FR AND USED IN FRONT OF SVC TO DETACH THE ADHESION OF RA LEAD, THE DETACHMENT DID NOT PROCEED. THEREFORE, THE PHYSICIAN ATTEMPTED TO REMOVE THE EVOLUTION11FR AND THE PRODUCT IN QUESTION, THE STAINLESS STEEL TIP OF THE PRODUCT CAME OFF. SINCE THERE WAS A POSSIBILITY THAT THE STAINLESS STEEL TIP MIGHT FLY TO OTHER PARTS OF THE BODY IF THE LR-TSS-11.0 WAS REMOVED AS IT WAS, A SHEATH FOR MEDTRONIC MICRA WAS INSERTED THROUGH THE FEMORAL VEIN AND THE TIP OF THE RA LEAD WAS RETRACTED. THE EVOLUTION 11FR AND LR-TSS-11.0 WERE ALSO INSERTED INTO THE MICRA SHEATH TO PREVENT THE STAINLESS STEEL TIP FROM FLYING OFF, AND A GUIDE WIRE WAS PASSED THROUGH THE EVOLUTION 11FR AND A VALVE WAS INSERTED THROUGH THE FEMORAL VEIN. THE BALLOON WAS PASSED THOUGH THE STAINLESS STEEL TIP AND INFLATED, THE STAINLESS STEEL TIP WAS FIXED WITH THE BALLOON, AND THEN REMOVED FROM THE FEMORAL VEIN. AFTER THE ADDITIONAL PROCEDURE, THE PATIENT WAS NO PROBLEMS. PHYSICIAN'S COMMENT OBTAINED BY A SALES REP FROM A DISTRIBUTOR : THE TIP WAS REMOVED

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20184749 ↗