MicroNester G52732Recalls & reported problems
Cook Incorporated · Micro Nester Embolization Coil · Class 2 · Implant
All models of MicroNester (17)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00827002527324), received between Apr 6, 2017 and Feb 4, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Recalls naming this device
- May 5, 2022Class IIOpen, Classified
The loading cartridges included with these devices may contain a small, unintended, stainless-steel cannula.
Z-1241-2022 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Detachment of Device or Device Component1
- Unraveled Material1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 4, 2026Unraveled Material
IT WAS REPORTED THAT A NESTER PLATINUM EMBOLIZATION MICROCOIL WAS DEFECTIVE. AN ADDITIONAL COIL WAS REQUIRED TO COMPLETE THE ARTERY EMBOLIZATION PROCEDURE. AS REPORTED, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. UPON INITIAL INSPECTION OF THE RETURNED DEVICE, IT WAS DISCOVERED THAT THE COIL WAS UNRAVELED, THUS PROMPTING THIS REPORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24260287 ↗MalfunctionApr 6, 2017Detachment of Device or Device Component; Detachment of Device or Device Component
INTERNATIONAL CUSTOMER REPORTED THAT A PATIENT WAS UNDERGOING AN EMBOLIZATION PROCEDURE FOR AN UNSPECIFIED INDICATION. A NESTER PLATINUM EMBOLIZATION MICROCOIL DETACHED WITHIN A COMPETITORS' CATHETER DURING DEPLOYMENT. THE COIL BECAME LODGED WITHIN THE CATHETER AND COULD NOT BE REMOVED. THE PHYSICIAN REMOVED THE CATHETER WITH THE LODGED COIL AND OBTAINED A REPLACEMENT CATHETER AND COILS TO COMPLETE THE PROCEDURE. THE PROCEDURE WAS DELAYED 10 MINUTES. NO FURTHER EVENT OR PATIENT INFORMATION WAS PROVIDED. NO UNINTENDED SECTION OF THE DEVICE REMAINED WITHIN THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6464757 ↗
FDA clearance and classification
The FDA regulates product code KRD (device, vascular, for promoting embolization) under 21 CFR 870.3300 as a Class II device. 21 CFR 870.3300 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the MicroNester G52732
Has the MicroNester G52732 been recalled?
Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1241-2022 (Class II), began on May 5, 2022: The loading cartridges included with these devices may contain a small, unintended, stainless-steel cannula. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
What problems have been reported with the MicroNester G52732?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between Apr 6, 2017 and Feb 4, 2026. In those reports, the most common specific device problems are “Detachment of Device or Device Component” (1) and “Unraveled Material” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the MicroNester G52732?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the MicroNester G52732 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the MicroNester G52732, and is it still sold?
The FDA's device database lists Cook Incorporated as the company responsible for it (brand MicroNester, model G52732). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization117 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page