Axium QC-5-20-HELIXRecalls & reported problems
Micro Therapeutics, Inc. · QC-5-20-HELIX BARE AXIUM HELIX COIL · Class 2 · Implant
All models of Axium (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00836462010154), received between Dec 20, 2019 and Dec 20, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K081465); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 20, 2019Detachment of Device or Device Component; Detachment of Device or Device Component
MEDTRONIC RECEIVED INFORMATION THAT THE AXIUM IMPLANT COIL PREMATURELY DETACHED. PRIOR TO THE EVENT, AN ECHELON MICROCATHETER WAS PLACED IN THE ANEURYSM AND ONE AXIUM COIL WAS SUCCESSFULLY IMPLANTED IN THE ANEURYSM. THEN THE PHYSICIAN INTRODUCED THE AXIUM QC 3D (REPORTED DEVICE) AND INTRODUCED IT HALFWAY AND THE COIL CAME OUT INTO THE PARENT ARTERY. THE PHYSICIAN PULLED THE COIL BACK TO REPOSITION IT, BUT RESISTANCE WAS FELT AND IT PREMATURELY DETACHED. HALF OF THE COIL WAS HANGING IN THE PARENT ARTERY AND IT WAS REMOVED WITH THE HELP OF THE REBAR 27 AND SOLITAIRE 2 (6 X 30). NO PATIENT INJURY WAS REPORTED AS A RESULT OF THE EVENT. THE PATIENT WAS UNDERGOING EMBOLIZATION TREATMENT OF A RUPTURED ANEURYSM MEASURING 7MM X 3.78MM LOCATED IN THE A-COMM. THE PATIENT'S BLOOD FLOW WAS NORMAL. THE VASCULATURE WAS MODERATE IN TORTUOSITY. THE PUSHWIRE WAS NOT BENT OR BROKEN. THE PHYSICIAN ONLY ATTEMPTED TO REPOSITION THE COIL ONCE. THERE WAS NO ATTEMPT TO DETACH THE COIL. THE PHYSICIAN DID NOT ROTATE THE DELIVERY PUSHER. A CONTINUOUS FLUSH WAS ADMINISTERED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9506963 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K081465. One submission often covers many models, so check the product and lot details in each record.
- Z-0873-2012 · Mar 1, 2010 · TerminatedAxium Detachable Coil System QC-2-1-Helix The ev3 Axium Detachable Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular ab
- Z-0874-2012 · Mar 1, 2010 · TerminatedAxium Detachable Coil System QC-7-30-Helix The ev3 Axium Detachable Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular a
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization115 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page