Skip to content

Axium QC-22-50-3DRecalls & reported problems

Micro Therapeutics, Inc. · QC-22-50-3D BARE AXIUM 3D COIL · Class 2 · Implant

All models of Axium (28)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00836462010536), received between Mar 26, 2019 and Oct 12, 2023 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

2 other recalls cover devices cleared under the same FDA submission (K081465); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Component or Accessory Incompatibility1
  • Detachment of Device or Device Component1
  • Material Deformation1
  • Physical Resistance/Sticking1
  • Separation Failure1

Patient problems

  • No Known Impact Or Consequence To Patient3
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 12, 2023Break; Material Deformation; Physical Resistance/Sticking; Break; Material Deformation; Physical Resistance/Sticking

    ADDITIONAL INFORMATION WAS RECEIVED THAT THE ENTIRE BROKEN AXIUM COIL WAS REMOVED FROM THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17919217 ↗
  • MalfunctionSep 11, 2019Component or Accessory Incompatibility; Component or Accessory Incompatibility

    MEDTRONIC RECEIVED A REPORT THAT AN AXIUM COIL "WAS NOT VISIBLE."

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8992827 ↗
  • MalfunctionSep 11, 2019Detachment of Device or Device Component; Detachment of Device or Device Component

    MEDTRONIC RECEIVED AREPORT THAT AN AXIUM COIL UNINTENTIONALLY DETACHED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8992821 ↗
  • MalfunctionMar 26, 2019Separation Failure; Separation Failure

    MEDTRONIC RECEIVED INFORMATION THAT THE PHYSICIAN COULD NOT DETACH THE IMPLANT COIL WITH THE INSTANT DETACHER AFTER THE COIL WAS INSERTED INTO THE ANEURYSM. ANOTHER INSTANT DETACHER (WITH DIFFERENT LOT) WAS USED AND THE IMPLANT COIL STILL COULD NOT BE DETACHED. THERE WAS ALSO AN ATTEMPT TO DETACH THE COIL USING THE MANUAL METHOD (BREAKING OF THE HYPOTUBE, AN ALTERNATIVE DETACHMENT METHOD PRESENTED IN THE INSTRUCTIONS FOR USE) BUT THE COIL STILL DID NOT DETACH. IN THE END, PRIME COILS WERE USED AND THEY WERE ABLE TO BE SUCCESSFULLY DETACHED. NO PATIENT INJURY WAS REPORTED AS A RESULT OF THE EVENT. THE PATIENT WAS UNDERGOING EMBOLIZATION TREATMENT OF CEREBRAL ANEURYSM MEASURING 24MM. THE PATIENT¿S VASCULATURE WAS MEDIUM IN TORTUOSITY. ANCILLARY DEVICES: PRIME COILS.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8454532 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K081465. One submission often covers many models, so check the product and lot details in each record.

  • Z-0873-2012 · Mar 1, 2010 · Terminated
    Axium Detachable Coil System QC-2-1-Helix The ev3 Axium Detachable Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular ab
  • Z-0874-2012 · Mar 1, 2010 · Terminated
    Axium Detachable Coil System QC-7-30-Helix The ev3 Axium Detachable Coil System is indicated for the endovascular embolization of intracranial aneurysms and other neurovascular a

Other Device, Vascular, for Promoting Embolization devices

All Device, Vascular, for Promoting Embolization devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page