HELIOS H05110URecalls & reported problems

Oscor Inc. · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00836559006640), received between Oct 8, 2018 and Dec 31, 2018 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Material Rupture” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Material Rupture2

Patient problems

  • No Information1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 31, 2018Material Rupture; Material Rupture

    ON (B)(6) 2019, THE FOLLOWING ADDITIONAL INFORMATION WAS RECEIVED. IT WAS REPORTED, ATTEMPTED TO CONNECT THE HELIOS WITH A TEMPORARY PACEMAKER ON ICU. A 6 FRENCH SHEATH WAS USED; CATHETER COULD NOT BE PUSHED THROUGH THE SHEATH AND TORE WHILE TRYING. FINALLY ANOTHER CATHETER WAS USED, NO FURTHER PROBLEMS. THERE WERE NO IDENTIFIABLE PROBLEMS WITH THE PATIENT. IT WAS NOT DOCUMENTED IF THE BALLOON WAS TESTED PRIOR TO USE, NOR HOW MUCH AIR WAS INSERTED INTO THE BALLOON. THE ISSUE WAS RESOLVED BY USING ANOTHER CATHETER. IT CANNOT BE CONFIRMED IF THE PRODUCT WAS INSIDE OR OUTSIDE OF THE PATIENT WHEN THE EVENT OCCURRED. THE CLINIC WAS CALLED BUT WAS INFORMED THEY DID NOT DOCUMENT THE COMPLAINT AS SUCH.

    Patient problems: No Information

    MAUDE report 8206739 ↗
  • MalfunctionOct 8, 2018Material Rupture; Material Rupture

    IT WAS REPORTED THAT DURING IMPLANTING THE ELECTRODE FOR TEMPORARY STIMULATION OF THE HEART, THE HELIOS BALLOON WAS INFLATED TO 3MM AND BURST. THE SYRINGE USED WAS THE ONE SUPPLIED IN THE KIT TOGETHER WITH THE HELIOS. THE ISSUE WAS RESOLVED BY OPENING ANOTHER HELIOS UNIT AND INFLATING TO 1MM. NO ADDITIONAL INFORMATION IS AVAILABLE AND NO OTHER ADVERSE EVENT WAS REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7944802 ↗

FDA clearance and classification

Cleared through 510(k) K072770 on Jan 22, 2008 (decision: Substantially Equivalent). Submitted by Oscor, Inc. as “Temporary Pacing Lead, Series Tbb, Model Helios (Tm)”. The FDA review took 116 days. FDA record ↗

The FDA regulates product code LDF (electrode, pacemaker, temporary) under 21 CFR 870.3680 as a Class II device. 21 CFR 870.3680 ↗

The FDA lists this type of device as life-sustaining or life-supporting.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the HELIOS H05110U

Has the HELIOS H05110U been recalled?

No FDA recall record in our data names this exact device identifier (DI 00836559006640), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the HELIOS H05110U?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Oct 8, 2018 and Dec 31, 2018. In those reports, the most common specific device problem is “Material Rupture” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the HELIOS H05110U?

None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the HELIOS H05110U FDA approved?

It was cleared through 510(k) K072770 on Jan 22, 2008. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the HELIOS H05110U, and is it still sold?

The FDA's device database lists Oscor Inc. as the company responsible for it (brand HELIOS, model H05110U). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Electrode, Pacemaker, Temporary devices

All Electrode, Pacemaker, Temporary devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page