Skip to content

HELIOS HK05110URecalls & reported problems

Oscor Inc. · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00836559007265), received between Jul 18, 2017 and Jul 18, 2017 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

1 other recall cover devices cleared under the same FDA submission (K861403); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1
  • Material Integrity Problem1

Patient problems

  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 18, 2017Break; Material Integrity Problem; Break; Material Integrity Problem

    THE CUSTOMER REPORTED THEY RECEIVED A COMPLAINT FROM (B)(6). THE PATIENT HAS BEEN HARMED. ACCORDING TO THE HOSPITAL, IT WAS NOTICED THAT THE PART OF THE SLUICE THAT IS INTRODUCED OF ADELANTE SIGMA PLUS OF THE HELIOS CONVENIENCE KIT IS TORN OFF IN THE PATIENT. THE FRAGMENT CAME WITH THE BLOOD FLOW INTO THE HEART AND COULD BE RECOVERED BY EMERGENCY SURGERY. ACCORDING TO OUR MR. (B)(6), THE PATIENT WAS IN DANGER OF LIFE. ADDITIONAL INFORMATION AND THE RETURN OF THE PRODUCT - IF POSSIBLE - WILL FOLLOW. ON 6/21/2017 ADDITIONAL INFORMATION RECEIVED FROM CUSTOMER: PLEASE LET ME DESCRIBE ME IN DETAIL THE COMPLAINT OF THE HOSPITAL IN (B)(6). THE HELIOS CONVENIENCE KIT HAS BEEN USED IN THE INTENSIVE CARE UNIT FOR CRITICAL SITUATIONS ONLY. SO FAR THEY USED AROUND FIVE HELIOS CONVENIENCE KITS. DURING EXTRACTING THE HELIOS AND ADELANTE SIGMA PLUS THE DOCTOR RECOGNIZED, THAT HE DIDN'T SEE THE WHITE SHEATH OF THE SIGMA PLUS BUT ONLY THE BLUE PART OF THE HELIOS SHEATH. THE PATIENT GOT IMMEDIATELY AN EMERGENCY ANGIOGRAPHY. DURING THIS PROCEDURE THE SHEATH OF THE SIGMA PLUS HAS BEEN DETECTED IN THE RIGHT VENTRICLE. THEY COULD SAVE THE SHEATH WITH A SNARE. THE PART OF THE SIGMA PLUS HAS BEEN EXTRACTE

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 6723328 ↗

FDA clearance and classification

Cleared through 510(k) K861403 on Jun 27, 1986 (decision: Substantially Equivalent). Submitted by Oscor Medical Corp. as “Tb Series Bipolar Pacing Leads”. The FDA review took 73 days. FDA record ↗

The FDA regulates product code LDF (electrode, pacemaker, temporary) under 21 CFR 870.3680 as a Class II device. 21 CFR 870.3680 ↗

The FDA lists this type of device as life-sustaining or life-supporting.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K861403. One submission often covers many models, so check the product and lot details in each record.

  • Z-0391-2019 · Sep 26, 2018 · Terminated
    TB Series Bipolar Pacing Leads, French Size 4F, 5F, 6F for Curve Type Straight, Atrial J, 60 degree Curve, and Right Heart. TB is packaged for sterile single use in a double tray

Common questions about the HELIOS HK05110U

Has the HELIOS HK05110U been recalled?

No FDA recall record in our data names this exact device identifier (DI 00836559007265), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the HELIOS HK05110U?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 18, 2017. That report lists device problems “Break” (1) and “Material Integrity Problem” (1); patient problem “Device Embedded In Tissue or Plaque” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the HELIOS HK05110U?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the HELIOS HK05110U FDA approved?

It was cleared through 510(k) K861403 on Jun 27, 1986. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the HELIOS HK05110U, and is it still sold?

The FDA's device database lists Oscor Inc. as the company responsible for it (brand HELIOS, model HK05110U). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Electrode, Pacemaker, Temporary devices

All Electrode, Pacemaker, Temporary devices →

Sources and updates