Skip to content

Viant Medical, LLC T2776Recalls & reported problems

Viant Medical · Acetabular Reamer 55 mm · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00840096405873), received between Mar 28, 2024 and Mar 28, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 28, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED DURING A PROCEDURE ON THE RIGHT SIDE OF THE PATIENT THAT WHILE REAMING, THE REAMED SPACE APPEARED TOO LARGE FOR THE CUPS. THE SURGEON ATTEMPTED TO IMPLANT A SIZE 56MM CUP USING THE SIZE 55MM REAMER (THIS REPORT). THE SURGEON THEN ATTEMPTED TO IMPLANT A SIZE 58MM CUP USING THE 57MM REAMER (REPORT 3004976965-2024-00007). A SCREW WAS USED TO TRY AND IMPLANT ONE OF THE CUPS, BUT THERE STILL DID NOT SEEM TO BE GOOD FIXATION. BOTH SIZE 56MM AND 58MM CUPS WERE WASTED. A SIZE 60MM CUP WAS ULTIMATELY IMPLANTED AND THE SURGEON DID NOT HAVE TO REAM ANY ADDITIONAL BONE. THERE WAS SURGICAL DELAY OF ABOUT 30 MINUTE WITH NO CONSEQUENCES OR IMPACT TO PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19000462 ↗

Other Reamer devices

All Reamer devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page