Skip to content

Innomed, Inc. 3450Recalls & reported problems

Innomed, Inc. · Periosteal Elevator Angled Shaft with Straight Blade · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00840277105547), received between Mar 4, 2019 and Sep 27, 2020 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1
  • Material Fragmentation1

Patient problems

  • No Known Impact Or Consequence To Patient2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 27, 2020Break; Break

    REPORT MW5095964 WAS RECEIVED AT INNOMED FROM THE CENTER FOR DEVICES AND RADIOLOGICAL HEALTH ON 8/28/2020 WITH FOLLOWING EVENT DESCRIPTION DOCUMENTED: "PATIENT HAVING SCHEDULED KNEE SURGERY. IN ONE OF THE EXTRA INSTRUMENT TRAYS THAT IS OCCASIONALLY USED. THERE WAS A SOFT TISSUE ELEVATOR NOTED TO BE BROKEN. INSTRUMENT WAS TAKEN OUT OF THE TRAY AND A NEW INSTRUMENT WAS OBTAINED. DID NOT REACH THE PATIENT. NO PATIENT HARM. FDA SAFETY REPORT ID #(B)(4). RESPONSE: IT IS CUSTOMARY FOR INNOMED TO RECEIVE THE AFFECTED DEVICE FOR EVALUATION AND INSPECTION. INNOMED WAS UNABLE TO CONTACT THE INITIAL REPORTER FOR REQUEST OF RETRIEVAL OF THE AFFECTED DEVICE AS THIS INFORMATION WAS NOT PROVIDED IN THE REPORT. INNOMED SURVEYED ITS INTERNAL COMPLAINTS DATABASE TO DETERMINE IF THERE WERE ANY ENTRIES OF THE PART WITH THE SAME DESCRIBED ISSUE. NO ENTRIES WERE FOUND. ADDITIONALLY, CURRENT INVENTORY OF THE PART WAS SURVEYED FOR THE DESCRIBED ISSUE. NONE WERE AFFECTED. THE DEVICE HAS BEEN ON THE MARKET SINCE FEBRUARY OF 2004, AND THIS IS THE FIRST ISSUE OF ITS KIND.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 10591239 ↗
  • MalfunctionMar 4, 2019Material Fragmentation; Material Fragmentation

    REPORT MW5083220 WAS RECEIVED AT INNOMED FROM THE CENTER FOR DEVICES AND RADIOLOGICAL HEALTH ON 2/4/2019 WITH FOLLOWING EVENT DESCRIPTION DOCUMENTED: PATIENT IN SURGERY FOR TOTAL HIP ARTHROPLASTY. A PERIOSTEAL ELEVATOR (CHISEL TYPE PRODUCT) # 3450 BEING UTILIZED BY THE SURGEON BROKE. ALL PIECES RETRIEVED. NO HARM TO PATIENT. REFERRED TO MANAGER OF CENTRAL STERILE TO ADDRESS. RESPONSE: INNOMED CONTACTED THE INITIAL REPORTER ON THE DAY THE DEVICE WAS RECEIVED AND REQUESTED TO HAVE IT RETURNED FOR AN EVALUATION. RETURN AUTHORIZATION NUMBER (B)(4) AND STERILIZATION CONFIRMATION FORM WERE FORWARDED ON THE ABOVE REFERENCED DATE. THE INTERNAL COMPLAINTS DATABASE WAS SURVEYED FOR THE ABOVE DESCRIBED ISSUE. UPON RECEIPT AT INNOMED ON 2/11/2019, THE DEVICE WAS INSPECTED AND EVALUATED BY QUALITY CONTROL. THE FOLLOWING RESULTS WERE DOCUMENTED: PERFORMED EVALUATION OF FAILURE AND FOUND DAMAGE TO THE WORKING END THAT INDICATES THE INSTRUMENT WAS USED IN A LEVER MOTION ON A HARD OBJECT. SEE ATTACHED PICTURES. THE TIP IN THREE PLACES IS ROLLED DOWNWARD INDICATING A FORCE WAS USED THAT EXCEEDED THE FORCE REQUIRED TO ELEVATE PERIOSTEAL TISSUE. THIS INSTRUMENT WAS DESIGNED TO ELEVATE THE PERIOSTEAL T

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8387106 ↗

FDA clearance and classification

The FDA regulates product code HTE (elevator) under 21 CFR 878.4800 as a Class I device. 21 CFR 878.4800 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Innomed, Inc. 3450

Has the Innomed, Inc. 3450 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00840277105547), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Innomed, Inc. 3450?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 4, 2019 and Sep 27, 2020. In those reports, the most common specific device problems are “Break” (1) and “Material Fragmentation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Innomed, Inc. 3450?

None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Innomed, Inc. 3450 FDA approved?

Devices of this type (product code HTE) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Innomed, Inc.

Who makes the Innomed, Inc. 3450, and is it still sold?

The FDA's device database lists Innomed, Inc. as the company responsible for it (brand Innomed, Inc., model 3450). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Elevator devices

All Elevator devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page