Optima Coil System OPTI0220BLKRecalls & reported problems
Balt USA LLC · The Optima Coil System is a series of specialized coils that are inserted into the vasculature under angiographic visualization to embolize intracranial aneurysms and other vascular anomalies. The system consists of an embolization coil implant comprised of platinum and tungsten, affixed to a delivery pusher to facilitate insertion into the hub of a microcatheter. The system is available in various shapes, lengths, and sizes. The devices are to be placed into aneurysms to create blood stasis, reducing flow into the aneurysm and thrombosing the aneurysm. Upon positioning coils into the aneurysm, the coils are detached from the delivery pusher in a serial manner until the aneurysm is occluded. · Class 2 · Implant
All models of Optima Coil System (379)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00840303711858), received between Jul 18, 2025 and May 14, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Premature Separation” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Premature Separation2
- Migration1
- Stretched1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 14, 2026Premature Separation
IT WAS REPORTED THAT: "DURING A COIL EMBOLIZATION OF MMA FOR CSDH, THE PHYSICIAN ATTEMPTED TO DEPLOY OPTIBLOCK 2X20 COIL THROUGH A SL-10 MICROCATHETER. THE COIL PUSHED BACK THE SL-10 AS IT WAS ADVANCED OUT OF DISTAL END. THE PHYSICIAN RESHEATHED COIL AND REPOSITIONED MICRO MORE DISTAL. HE THEN RELOADED THE OPTIBLOCK 2X20 COIL AND AFTER DEPLOYING THE FIRST TWO LOOPS OF COIL HE LOST 1 TO 1 AND IT WAS OBSERVED THAT THE COIL WAS NO LONGER ATTACHED TO DELIVERY WIRE. HE USED A SYNCHRO WIRE TO PUSH THE REMAINDER OF THE COIL OUT OF SL-10. THIS WAS NOTED TO BE DIFFICULT BUT THE ENTIRE COIL WAS ULTIMATELY PUSHED INTO VESSEL. COIL WAS PREPPED PER DFU. NO PATIENT INJURY OCCURRED. THE DELIVERY WIRE IS AVAILABLE FOR RETURN." INCIDENT REPORT FORM SUBMITTED FOR THIS COMPLAINT INDICATES THAT NO PATIENT INJURY WAS SUSTAINED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25174268 ↗MalfunctionJul 18, 2025Stretched; Migration; Premature Separation; Stretched; Migration; Premature Separation
IT WAS REPORTED THAT: "WHEN RESHEATHING THE 2X20 COIL IN THE HEADWAY DUO 156CM MICROCATHETER IN THE MMA, THE COIL STRETCHED AND THEN BROKE OFF THE DELIVERY WIRE. THE COIL WAS NOT ABLE TO BE RECAPTURED AND WAS LEFT IN THE ECA WHERE IT BROKE OFF. FORTUNATELY, NO PATIENT HARM. THE SAME MICROCATHETER WAS USED TO DELIVER COILS FOR THE REMAINDER OF THE CASE." UPDATE 23JUN2025 - ADDITIONAL INFORMATION RECEIVED FROM THE ISSUER: " IS IT KNOWN APPROXIMATELY WHERE THE ACTUAL "BREAK" ALONG THE COIL TOOK PLACE (DID IT OCCUR AT THE DETACHMENT ZONE, DID THE IMPLANT COIL WIND BREAK, ETC.)? THE ACTUAL COIL IMPLANT STRETCHED MIDWAY THROUGH AND THEN BROKE AT THE DETACHMENT ZONE. WHERE IT IS MENTIONED "WHEN RESHEATHING THE 2X20 COIL IN THE HEADWAY DUO 156CM MICROCATHETER IN THE MMA", DOES THIS MEAN THE IMPLANT WAS DEPLOYED FROM THE MC AND THE PHYSICIAN WAS ATTEMPTING TO RETRACT BACK INTO THE MICROCATHETER? THE MICROCATHETER WAS KICKING BACK AS HE WAS TRYING TO DEPLOY THE COIL, SO THERE WAS SOME RESHEATHING OF THE COIL INSIDE THE MICROCATHETER TO REPOSITION. BASED ON THE ANATOMICAL LOCATION OF THE PROCEDURE, WHAT LEVEL OF VESSEL TORTUOSITY WOULD YOU CONSIDER WAS ENCOUNTERED BY THE COIL SYSTEM? THERE WA
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22546351 ↗
Other Device, Neurovascular Embolization devices
- POD RBYPODJ60-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION355 reports
- Penumbra System SCH1Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION295 reports
- RUBY Coil RBY4C0860-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION276 reports
- Smart Coil 400SMTHXSFT0208Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION165 reports
- Penumbra System RH1-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION154 reports
- Optima Coil System OPTI0208CSS10Balt USA LLC · Device, Neurovascular Embolization3 recalls3 reports
- POD RBYPOD6-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION148 reports
- POD RBYPODJ30-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION132 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page