Tornier HRS Max ARS10245Recalls & reported problems
Tornier, Inc. · Inserter & Extractor Handle · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00840338603937), received between Dec 16, 2025 and Dec 16, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Device Difficult to Setup or Prepare1
- Material Protrusion/Extrusion1
- Mechanical Jam1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 16, 2025Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
DRIVER DID NOT FIT DOWN BROACH HANDLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23820947 ↗MalfunctionDec 16, 2025Material Protrusion/Extrusion; Mechanical Jam; Material Protrusion/Extrusion; Mechanical Jam
THE LONG DRIVER (ARS742700) WOULD NOT PASS THROUGH THE BROACH HANDLE (ARS10245) DUE TO A PIN ON THE HANDLE PROTRUDING TOO FAR, BLOCKING THE DRIVER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23817847 ↗
FDA clearance and classification
The FDA regulates product code HWA (impactor) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Tornier HRS Max ARS10245
Has the Tornier HRS Max ARS10245 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00840338603937), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Tornier HRS Max ARS10245?
The FDA's MAUDE database lists 2 adverse event reports for this device, received on Dec 16, 2025. In those reports, the most common specific device problems are “Device Difficult to Setup or Prepare” (1), “Material Protrusion/Extrusion” (1) and “Mechanical Jam” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Tornier HRS Max ARS10245?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Tornier HRS Max ARS10245 FDA approved?
Devices of this type (product code HWA) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Tornier, Inc.
Who makes the Tornier HRS Max ARS10245, and is it still sold?
The FDA's device database lists Tornier, Inc. as the company responsible for it (brand Tornier HRS Max, model ARS10245). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other IMPACTOR devices
- PINNACLE 2217-50-041Depuy (Ireland) · IMPACTOR4,276 reports
- ATTUNE 2544-01-006Depuy (Ireland) · IMPACTOR1 recall2,528 reports
- ATTUNE 2544-01-003Depuy (Ireland) · IMPACTOR1 recall1,491 reports
- ATTUNE 2544-01-017Depuy (Ireland) · IMPACTOR1 recall1,454 reports
- ATTUNE 2544-01-004Depuy (Ireland) · IMPACTOR1 recall873 reports
- DURALOC 2360-71-000Depuy Orthopaedics, Inc. · IMPACTOR715 reports
- SPECIALIST 2581-11-000Depuy (Ireland) · IMPACTOR703 reports
- INHANCE 6205-10-103Depuy (Ireland) · IMPACTOR334 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page