ICU Medical CH-10-10Recalls & reported problems
Icu Medical, Inc. · ChemoClave™ Bag Spike, 10 Units · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00840619033859), received between Oct 31, 2024 and Oct 31, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).
7 other recalls cover devices cleared under the same FDA submission (K081361); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fluid/Blood Leak1
- Material Separation1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 31, 2024Fluid/Blood Leak; Material Separation; Fluid/Blood Leak; Material Separation
IT WAS REPORTED THAT A CHEMOCLAVE® BAG SPIKE, (B)(4) UNITS GENERATED A LEAK DURING PATIENT USE. THE REPORT STATES THAT THE SAMPLE WAS DEFECTIVE. NO STAFF OR PATIENTS WERE EXPOSED TO HAZARDOUS DRUGS. NO MEDICAL ATTENTION IS REQUIRED FOR EITHER STAFF OR PATIENTS. THE DRUG INVOLVED WAS CYCLOPHOSPHAMIDE AND (B)(4). DRUG DOSE, DILUENT, CONCENTRATION 750MG/D5W 500ML 750MG IN 551.75ML. THE AMOUNT SPILLED WAS APPROXIMATELY 20 ML AND NO SPILL KIT WAS USED. THE REPORT STATES THAT THE SPIKES BREAK WITH THE CYCLOPHOSPHAMIDE PRODUCT BRANDED AVYXA. AFTER THE ADDITION OF MEDICATION, THE SPIKE WAS FLUSHED. MEDICATION WAS STILL IN THE CHEMO BAG. PROPER GARBING WAS USED TO RETRIEVE OTHER MEDICATIONS IN THE SAME BAG. THE SAMPLE WAS AVAILABLE FOR EVALUATION. STERILE SAMPLES OF THE SAME LOT # WERE AVAILABLE FOR TESTING. A SAMPLE PHOTO WAS PROVIDED SHOWING THE SAMPLE AND IT SEEMS THAT IT WAS BROKEN OFF. THE CUSTOMER DOES NOT USE ICU FLUIDS, THEY USE BRAUN. THERE WAS NO PATIENT HARM REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20582828 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K081361. One submission often covers many models, so check the product and lot details in each record.
- Z-3160-2026 · May 12, 2026 · Open, ClassifiedIV Sets with drip chambers
- Z-3158-2026 · May 12, 2026 · Open, ClassifiedOncology sets with drip chambers
- Z-1566-2021 · Mar 16, 2021 · Open, ClassifiedREF CH3582 5 IN (13cm) APPX 0.57 ml, EXT SET, ANTI-SHIPHON VALVE, Spiros LOT 5125197 - Product Usage: for use in the preparation and patient administration of cytotoxic medications
- Z-1565-2021 · Mar 16, 2021 · Open, ClassifiedREF CH3397 Oncology Kit w/Spiros, Red Cap, Bag Spike w/Clave Additive Port LOT 5118610 - Product Usage: for use in the preparation and patient administration of cytotoxic medicatio
- Z-0701-2021 · Aug 31, 2020 · Open, Classified5 IN (13 cm) Appx 1.5 ml, Bag Spike Adapter, Spiros, REF: 20123-01; 75" (191 cm) Appx 9.1 ml, 20 Drop Admin Set w/ Integrated Clave Drip Chamber, Clave, Spiros, REF: CH3035; 40" (1
- Z-1092-2019 · Feb 21, 2019 · Terminatedicumedical ChemoClave Vented Vial Spike, 20 mm, REF CH-70S . Used in IV administration sets. The ChemoClave is a needle-free Closed System Transfer Device (CSTD) that mechanica
- Z-1093-2019 · Feb 21, 2019 · Terminatedicumedical ChemoClave Vented Vial Spike, 20 mm, REF CH-80S. Used in IV administration sets. The ChemoClave is a needle-free Closed System Transfer Device (CSTD) that mechanical
Other Set, administration, intravascular devices
- Autosoft XC 1001680Unomedical A/S · Set, Administration, Intravascular1 death16,105 reports
- Autosoft90™ 1002817Unomedical A/S · Set, Administration, Intravascular1 recall11,907 reports
- Minimed™ Quick-set™ MMT-399AUnomedical A/S · Set, Administration, Intravascular9 deaths8,669 reports
- Medtronic Extended MMT-431AUnomedical A/S · Set, Administration, Intravascular3 deaths8,574 reports
- MiniMed™ Mio™ Advance MMT-242AUnomedical A/S · Set, Administration, Intravascular15 deaths8,164 reports
- CADD 21-7302-24Icu Medical, Inc. · Set, administration, intravascular4 recalls1 death4,657 reports
- Autosoft XC 1001681Unomedical A/S · Set, Administration, Intravascular1 death4,216 reports
- Minimed™ Quick-set™ MMT-397AUnomedical A/S · Set, Administration, Intravascular19 deaths4,134 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page