ICU Medical 46100-83Recalls & reported problems

Icu Medical, Inc. · Cath Lab Kit w/Waste Bag System, 3 Port "OFF" Manifold (600 psi), Transpac™ IV, 72" Spike Sets and 48" HP Tubing · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00840619069162), received between Aug 13, 2025 and Aug 13, 2025 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Air/Gas in Device” (2 reports).

1 other recall cover devices cleared under the same FDA submission (K932141); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Air/Gas in Device2

Patient problems

  • Air Embolism1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 13, 2025Air/Gas in Device; Air/Gas in Device

    A COMPLAINT WAS RECEIVED REGARDING A CATH LAB KIT FOR INDUSTRIAL DRUG SUPPLIES, USA, THAT EXPERIENCED AIR IN LINE DURING INFUSION RESULTING IN A CORONARY AIR EMBOLISM BUT NO INTERVENTION REQUIRED. THE REPORTER STATED THAT "THEY HAVE FAULTY MANIFOLD/SYRINGES INTRODUCING AIR IN THE SYSTEM. THE PATIENT DEVELOPED CORONARY AIR EMBOLISM BUT WAS LUCKILY STABLE." THE PROBLEM OCCURRED DURING INFUSION DURING INJECTING CORONARIES. THE TYPE OF PROCEDURE WAS CARDIAC CATHETERIZATION. THE LENGTH OF TIME THE PRODUCT WAS IN USE WAS 30 MINUTES. THERE WAS NO SERIOUS INJURY/DEATH NOR BLOOD LOSS. NO CHEMO LEAK NOR UNPROTECTED CHEMO EXPOSURE. NO MEDICAL/SURGICAL INTERVENTION REQUIRED. THE DEVICE(S) WAS CHANGED OUT/REPLACED WITH NO FURTHER PROBLEMS ENCOUNTERED. THE PATIENT HAD JUST PAIN AND ECG CHANGES DUE TO AIR EMBOLISM. THE STATUS OF THE PATIENT WAS RETURNED TO BASELINE CONDITION.

    Patient problems: Air Embolism

    MAUDE report 22800410 ↗
  • MalfunctionAug 13, 2025Air/Gas in Device; Air/Gas in Device

    A COMPLAINT WAS RECEIVED REGARDING A CATH LAB KIT FOR INDUSTRIAL DRUG SUPPLIES, USA, THAT EXPERIENCED AIR IN LINE DURING INFUSION. THE REPORTER STATED THAT THEY HAVE FAULTY MANIFOLD/SYRINGES INTRODUCING AIR IN THE SYSTEM. THE PROBLEM OCCURRED DURING INFUSION DURING INJECTING CORONARIES. THE TYPE OF PROCEDURE WAS CARDIAC CATHETERIZATION. THE ISSUE WAS NOT DETECTED PRIOR TO DIRECT PATIENT USE. THE LENGTH OF TIME THE PRODUCT WAS IN USE WAS 30 MINUTES. THERE WAS NO SERIOUS INJURY/DEATH NOR BLOOD LOSS. NO CHEMO LEAK NOR UNPROTECTED CHEMO EXPOSURE. NO MEDICAL/SURGICAL INTERVENTION REQUIRED. THE DEVICE(S) WAS CHANGED OUT/REPLACED WITH NO FURTHER PROBLEMS ENCOUNTERED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22800233 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K932141. One submission often covers many models, so check the product and lot details in each record.

  • Z-0621-05 · Nov 2, 2004 · Terminated
    Catheterization Kits containing Angiographic Syringes with rotator connector.

Other Catheter, intravascular, diagnostic devices